Cheyenne Sol Nova Скачать руководство пользователя страница 12

27

EN

There are three ways to supply power to 
the SOL Nova:

Thir

d party power unit

Cheyenne Power Unit

Capable adapters 
provided

Y cable adapter

1.  Connecting it to a Cheyenne Power Unit 

with  the  connecting  cable  provided  in 
the scope of delivery (recommended)

2.  Connecting  it  to  an  third-party  power 

unit with the 6.3 mm jack and the cable 
adapter supplied
The  external  power  unit  must  deliver 
approx. 5 to 12.6 V direct current and 
the required start-up current indicated 
in  chapter  4.1.  If  more  than  about 
12.6 V is connected to the SOL Nova, it 
will shut down automatically.

3.  Connection  to  a  third-party  power 

supply  using  the  optionally  available 
Y-cable adapter with banana plugs
The  red  banana  plug  must  be 
connected  to  the  positive  terminal 
while the black banana plug must be 
connected to the negative terminal of 
the third-party power unit.

 

!

Connect  the  socket  of  the  connecting 
cable  (supplied)  to  the  connection  on 
the drive unit of the SOL Nova.

 

!

Plug  the  jack  of  the  connecting  cable 
fully  into  the  output  socket  on  the 
power unit.
If you are using an third party power unit, 
connect  up  its  terminals  correctly,  as 
described  in  the  operating  instructions 
of the third party power unit.

 

!

Connect  the  power  unit  to  the  mains 
power supply.

 

!

Cover the Power Unit or the third party 
power unit with a plastic sheet.

5.4 

Fitting the protective hose

ATTENTION

Damage to drive caused by fluid

If  fluid  gets  inside  the  drive  or  on  the 
connection, this can corrode the electri-
cal and mechanical components.

 

!

Always  use  a  protective  hose  with 
a  diameter  of  34  to  40 mm.  This 
corresponds to a hose width of 54 to 
63 mm.

 

!

Remove the connecting cable from the 
SOL Nova.

 

!

Cut  o

ff

  a  section  of  protective  hose  of 

an appropriate length.

 

!

Slide  this  section  of  protective  hose 
completely over the connecting cable.

 

!

Completely  unscrew  the  handle (1) 
from the drive.

 

!

Reconnect the connecting cable and its 
fitted protective hose to the SOL Nova.

1

Cheyenne SOL Nova

Содержание Sol Nova

Страница 1: ...sung Operating instructions Gebruiksaanwijzing Instructions Istruzioni per l uso Instrucciones de uso Manual de instruções Oδηγίες Opskrift Bruksanvisning Ohjeet Instrukcja obsługi Instrukce Navodila nt pl za uporabo Utasítás инструкции 说明 ...

Страница 2: ...1 Cheyenne SOL Nova 1 1 2 3 4 5 ...

Страница 3: ...gem Pega Motor Cabo de conexão Adaptador de cabo EL Safety cartridge Λαβή Μοτέρ Καλώδιο σύνδεσης Αντάπτορας καλωδίου DA Safety cartridge Gribestykke Drev Tilslutningskabel Kabeladapter SV Säkerhetspatron Grepp Motor Strömkabel Kabeladaptrar FI Safety cartridge turvapatruuna Kahvaosa Moottori Liitäntäjohto Johtosovitin PL Kartridż bezpieczeństwa Uchwyt Napęd Kabel zasilający Adaptery do kabla CS Be...

Страница 4: ...cting the power unit 26 5 4 Fitting the protective hose 27 5 5 Checking equipment 28 6 Using the SOL Nova 28 6 1 Setting the needle protrusion 28 6 2 Setting the piercing frequency 29 6 3 Loading with ink 29 7 Cleaning and maintaining the SOL Nova 29 7 1 Material compatibilities 29 7 2 Disinfecting surfaces 30 7 3 Cleaning surfaces 30 7 4 Cleaning handle in an ultrasonic bath 30 7 5 Sterilising ha...

Страница 5: ... notices Warning notices draw attention to the risk of personal injury and damage to materials and are structured as follows SIGNAL WORD Type of hazard Consequences Remedy Element Meaning Indicates a risk of injury Signal word Specifies the severity of the hazard see following table Type of hazard Gives the type and source of the hazard Conse quences Describes potential conse quences of non compli...

Страница 6: ... switch it off and place it safely so that it cannot roll away and fall to the ground Note the technical data quoted in these operating instructions and comply with operating transport and storage conditions see Page 24 Hand over the SOL Nova to a specialist retailer for inspection if it exhibits any external signs of damage or if it does not function in the usual manner 2 3 Important hygiene and ...

Страница 7: ...attooed Scars in the area that shall be tattooed Systemic infections and infectious dis eases e g Hepatitis type A B C D E or F HIV infection or acute local skin infections e g herpes rosacea During chemotherapy radiotherapy or high dosage corticosteroid therapy recommendation from four weeks be fore the start until four weeks after the end of the therapy Up to twelve months after a plastic sur ge...

Страница 8: ...nowledge of the risks and side effects see chapters Contra indications on page 22 and Side effects on page 22 2 7 Intended use The SOL Nova is a professional tattooing machine for the application of tattoos to the human skin in dry clean and smoke free environments and under hygienic conditions It must be prepared used and maintained in the manner described in these operating instructions In parti...

Страница 9: ... 5 to 12 6 V DC Power intake 3 W Start up current Max 2 5 A for max 200 ms Piercing frequency 25 to 150 Hz Stroke 3 5 mm Needle protrusion 0 to 4 0 mm Electrical connection 3 5 mm jack Drive Brushless DC motor Operating mode Continuous operation Diameter 33 mm Length 102 mm Weight Approx 150 g Sound emission pressure level Max 70 dB A Total vibration Max 2 5 m s 4 2 Operating conditions Ambient te...

Страница 10: ...ecommended disinfectants in chapter Material compatibilities on page 29 Switch off the power supply to the SOL Nova Check if the SOL Nova has been contaminated badly by the return flow of ink or bodily fluids In such cases perform the steps described in chapter Cleaning and maintaining the SOL Nova see Page 29 Wipe down the connecting cables the drive and the handle with a soft cloth dipped in dis...

Страница 11: ...the safety cartridge clockwise through approx 45 As you rotate it several locating points will engage audibly until the safety car tridge is firmly locked into position Check that the safety cartridge is firmly seated To remove the safety cartridge turn it anti clockwise and remove it from the handle 5 3 Connecting the power unit CAUTION Risk of short circuits If cable or cable connection is visib...

Страница 12: ... of the connecting cable supplied to the connection on the drive unit of the SOL Nova Plug the jack of the connecting cable fully into the output socket on the power unit If you are using an third party power unit connect up its terminals correctly as described in the operating instructions of the third party power unit Connect the power unit to the mains power supply Cover the Power Unit or the t...

Страница 13: ...pecialist retailer 6 Using the SOL Nova 6 1 Setting the needle protrusion CAUTION Risk of injury from excessive protrusion of needle A large needle protrusion permits a deep piercing depth If needle protrusion and piercing depth are excessive this can damage the subcutaneous layer Start with just a short length of needle protruding Switch on the power Adjust the needle protrusion while the SOL Nov...

Страница 14: ... of the safetycartridgeinthedesiredcolourofink for 2 to 3 seconds with the unit running Avoid contact with the ink container The ink is picked up by the needles Alternatively the ink can be filled into the opening on the safety cartridge using a sterile pipette 7 Cleaning and maintaining the SOL Nova CAUTION Risk of short circuits If components of the SOL Nova are dis mantled and cleaned while sti...

Страница 15: ... soft cloth dipped in a cleaning agent or a disinfectant Clean inaccessible surfaces e g the thread of the drive unit with a soft bristled nylon brush 7 4 Cleaning handle in an ultrasonic bath If the handle is severely soiled Use the cleaning agent Tickomed 1 or Tickopur R33 from manufacturer Dr H Stamm GmbH in accordance with the manufacturer s instructions Make sure that a pH value of 7 is not e...

Страница 16: ...able regulations for used electronic equipment If necessary consult the specialist retailer or the responsible authorities to learn about applicable regulations Provide containers at the workplace for legislation compliant disposal of contaminated components Dispose of used or defective safety cartridges in a sharps container safety box in accordance with the regulations applicable in your country...

Страница 17: ...al and workmanship for the product For the safety cartridges we guarantee sterility until the expiry date on the packaging providing that the packaging is sealed and undamaged and that the transport and storage conditions have been complied with For complaints relating to safety cartridges please advise us of the batch number printed on the label We do not provide warranty cover in respect of the ...

Страница 18: ...ine directive Basic Machine directive requirements used or complied with 1 1 2 1 1 3 1 1 5 1 1 6 1 2 2 1 3 1 1 3 2 1 3 3 1 3 4 1 3 7 1 5 1 1 5 2 1 5 4 1 5 5 1 5 6 1 5 8 1 5 9 1 5 11 1 5 13 1 6 1 1 6 3 1 7 1 1 1 7 4 1 7 4 1 1 7 4 2 1 7 4 3 2 1 2 1 1 2 1 2 2 2 1 2 2 1 1 The special technical documentation according to Appendix VII Part B has been established The person authorized to compile the tech...

Страница 19: ...0 3 3 ed 2 Electromagnetic compatibility EMC Part 3 2 Limits Limits for harmonic current emissions Electromagnetic compatibility EMC Part 3 3 Limits Limitation of voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated current 16 A per phase and not subject to conditional connection CISPR 14 2 1997 AMD1 2001 AMD2 2008 CISPR 14 1 2005 AMD1 2008...

Отзывы: