10
All the ports have been adjusted to work within direct current voltage of 12V-24V.
Higher voltage requires the use of an additional limiter installed on the module’s port.
More than one appliance can be controlled simultaneously. In order to do so, it is
essential to divide the signal, using one for each appliance.
Description:
Input - voltage port 12V-24V of the direct current.
Output - voltage port 12V-24V of the direct current depending on the mode of the
appliance.
The following chart shows mode ports where signals will appear depending on the
mode of the appliance. See illustration on p.6 for alphabetically referenced ports.
1 - port with signal
0 - port without signal
MODE
A
B
C
D
READY
1
0
0
0
WORKING
0
1
0
0
FUEL
0
0
1
0
ERROR
0
0
0
1
WAIT/COOLING
1
1
0
0
Содержание EFB1200