26
9. Commissioning
Check all internal parts are fitted correctly and there are no gaps between the
firebricks and baffles and the log retainer is secure:
Wood Burning Only 4,5 and 12 Series
Secondary baffle.
Firebricks: base, back, sides and baffle.
Metal flue protector strip on top of the back brick(not fitted 12 series)
Log retainer (not fitted on Milan 4 model)
Multi-Fuel 6 and 8 Series
Secondary baffle
Ash pan
Cast iron grate complete with riddling section.
Log retainer.
Firebricks: rear and sides.
Check all the levers are operating fully and freely. The riddling bar on the right
hand side of the stove should move the circular riddle grid. The riddle lever is
located on the front of the stove underneath the grid on the Apollo.
Check the Fuel Selector Lever (left hand side of stove) and under the fire cube
front left side on the Apollo 8 operating smoothly.
On completion of installation after allowing any fire cement & mortar to dry out,
the stove should be checked so that all seals/joints are sound. The flue should
also be checked by lighting a small fire and checking fumes are taken from the
appliance up the chimney and emitted safely.
Содержание Alpine 4 Series
Страница 1: ...1 For use in the UK and ROI NT27 October 2013 www chesneys co uk ...
Страница 11: ...11 Milan 4 Passive Figure 1 ...
Страница 12: ...12 Figure 1 Fitters notes ...
Страница 13: ...13 Apollo 8 Dimensions Apollo 4 Dimension ...
Страница 33: ...33 Riddling lever illustrated with the red arrow below Air flow bar Air Flow Bar Settings ...
Страница 45: ...45 Annual Service Record Date Company Name Signature Notes ...