3. Pre Installation
This appliance must be fitted in accordance with the current
Building Regulations and by an approved HETAS registered installer.
Health and Safety Precautions
Special care must be taken when installing the stove such that the
requirements of the Health and Safety at Work Act are met.
Note: This appliance is heavy and must be handled with care.
Adequate facilities must be available for loading, unloading and site handling.
The appliance is supplied fully assembled for a top flue arrangement.
The lid, door and internal parts can all be removed to reduce the stove weight
during installation
The paint is soft and vulnerable to marking; refer to the maintenance section.
Chesney’s stoves must be connected to a suitable chimney. Chesney’s
strongly recommend using a complete and compliant chimney lining system.
Inside the stove you will find an Installation and user manual and a pair of
Chesney’s Gauntlets. The multi-fuel stoves also have an ash pan and tool.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any
asbestos in the course of installation then please seek specialist guidance and
use appropriate protective equipment.
Metal Parts
When installing or servicing this stove care should be taken to avoid the
possibility of personal injury.
Ventilation
Please refer to Document J section 2 (table 1)
There must be an adequate air supply into the room in which the appliance is
installed to allow the appliance to function properly.
The installation of extract ventilation or other appliance that requires air for
combustion in the same area are not recommended and will effect this
appliance
.
Refer to page 17 Flue Requirements
Содержание Alpine 4 Series
Страница 1: ...1 For use in the UK and ROI NT27 October 2013 www chesneys co uk ...
Страница 11: ...11 Milan 4 Passive Figure 1 ...
Страница 12: ...12 Figure 1 Fitters notes ...
Страница 13: ...13 Apollo 8 Dimensions Apollo 4 Dimension ...
Страница 33: ...33 Riddling lever illustrated with the red arrow below Air flow bar Air Flow Bar Settings ...
Страница 45: ...45 Annual Service Record Date Company Name Signature Notes ...