21
SUPPORTED COMMAND CLASSES
Command Class
Version
Non-Secure
CC
Secure CC
ZWAVEPLUS_INFO
2
x
ASSOCIATION
2
x
MULTI_CHANNEL_ASSOCIATION_V2
3
x
ASSOCIATION_GRP_INFO
3
x
TRANSPORT_SERVICE
2
x
VERSION
3
x
MANUFACTURER_SPECIFIC
2
x
DEVICE_RESET_LOCALLY
1
x
INDICATOR
3
x
POWERLEVEL
1
x
SECURITY_2
1
x
SUPERVISION
1
x
MULTI_CHANNEL_V4
4
x
FIRMWARE_UPDATE_MD
5
x
APPLICATION_STATUS
1
x
CONFIGURATION_V4
4
x
SWITCH_MULTILEVEL
3
x
Supporting Command Class Basic
The basic command classes are mapped into the Switch Binary Command Class.
Supporting Command Class Indicator
The device supports the command class Indicator V3 (ID 0x50). When the device
receives an indicator set, the led blinks accordingly to the Indicator set received.
The color shown by the indicator will be:
RED:
if the device is included without Security
BLUE:
if the device is included in S2 Unauthenticated Mode
GREEN:
if the device is already included in S2 Authenticated Mode.