RIVETER REPAIR AND MAINTENANCE 

 

 

 

This riveter has been manufactured to give maximum service with minimum care.  
In order to keep the tools in optimum operating condition, it is advisable to set-up a Preventive Maintenance check list 
including, at a minimum, the following: 

 

Visually inspect the tool to make sure it is in good working condition and there are no fluid leaks 

 

Make sure the tool is bled regularly (page 15) 

 

Check the service sticker due date; service the tools on a regular basis.  

Should repair or service be necessary, follow the instructions given below.

 

 

 CAUTION 

 

  Read the tool manual instructions; it is advised that repair is conducted only by properly trained personnel. 

  Make sure the air is disconnected. 

  Protect the sealing surfaces to avoid damage. 

 

Tools and Service Kits Needed 

  Make sure that the proper service kit (

ordered separately

) and tools are available. 

o

 

SERVICE KIT: 

G746AKS –(contains Springs, Seals, O-Rings and Back-up Rings

 

o

 

TOOLS: 

G701/G704KT 

– tool kit and a 

Needle Nose Pair of Pliers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700A61 

700B65 

P1178 

837B700 

836B700 

700A77 

701A67 

700A60 

 

Содержание CHERRYMAX G746A

Страница 1: ...DATE 3 21 17 Federal Identification Code 11815 2017 Cherry Aerospace 1 1335 E Warner Ave Santa Ana Ca 92805 Tel 1 715 555 5522 Fax 1 715 851 6093 www cherryaerospace com Original Instructions G746A CO...

Страница 2: ...inspected according to generally accepted practices of companies manufacturing industrial or aerospace fasteners In the event of any breach of the foregoing warranty Buyer s sole remedy shall be to re...

Страница 3: ...ESSURE 90 to 120 PSI 6 2 to 7 6 bar STROKE 0 875 inch 22 23 mm MIN PULLING FORCE 1850 lbs 90 psi 8 23 kN 6 2 bar WEIGHT 4 25 lbs 2 26 kg CYCLE TIME One Second Approximately NOISE LEVEL 72 dB A VIBRATI...

Страница 4: ...Deflector facing away from the operator or critical aircraft structure use a Stem Catcher if possible Do not pound on the rear of the tool head to force rivets into holes Make sure that the air muffl...

Страница 5: ...1B 456 Straight NONE 4 5 6 2 All H747 456 5 NONE 4 5 6 2 All H753A 456 5 Right Angle NONE 4 5 6 2 All H781 456 H781A 456 Offset NONE 4 5 6 2 All H782 NONE 4 5 6 2 All CherryMAX AB CR4XXX H701B 456 Str...

Страница 6: ...4C3 CNP15CM4 CNP15CM5 H704 273NP CNP56C3 H704 280NP R721 3 60 CNP11C08 CNP11C3 H704 295NP CNP20C3 H704 223NP CNP06C3 H704 295NP CNP20C3 COMPOSITE H704 275NPC R721 275 CNP53C3 H704 290NPC CNP63C3 PULLI...

Страница 7: ...e tool is bled regularly page 15 Check the service sticker due date service the tools on a regular basis Should repair or service be necessary follow the instructions given below CAUTION Read the tool...

Страница 8: ...ton 37 by using wrench 700B65 hold the top of the piston with tool 700A61 to prevent it from turning Push piston out when completely unthreaded Remove packing plug 34 with the help of wrench 700B65 Ta...

Страница 9: ...1 700A22 Gasket 1 700A67 Spring 1 P27 Soc hd cap screw 4 P829 O ring 3 704 086 Handle assy 1 700A94 Spool Valve Assy 1 703A33 Trigger assy 1 49 700B95 Valve spool 1 22 P223 O ring 1 50 700A18 Filter 1...

Страница 10: ...TM G746A Rev B DCR 17 0231 DATE 3 21 17 Federal Identification Code 11815 2017 Cherry Aerospace 10 G746A CROSS SECTION...

Страница 11: ...DATE 3 21 17 Federal Identification Code 11815 2017 Cherry Aerospace 11 G746A TOP ASSEMBLY ITEM P N DESCRIPTION QTY 1 846 016 Head assy 1 17 P832 O ring 1 18 700A22 Gasket 1 19 P27 Soc hd cap screw 4...

Страница 12: ...assy 1 845 019 Head Cylinder 1 2A 845B6 Nose fitting 1 P701 O ring 2 P998 Back up ring 1 P304 Quad Ring 1 P106 Back up ring 1 845 017 Head piston 1 P848 O Ring 1 P572 Stat o seal 1 P573 Button head sc...

Страница 13: ...8 Power piston rod 1 P727 O ring 1 P838 O ring 2 P115 Back up ring 2 700B93 Packing plug 1 P731 Back up ring 2 P730 Quad ring 1 700B6 Air piston 1 P737 Locknut 1 P725 O ring 1 700B4 Handle base 1 P735...

Страница 14: ...used fluid otherwise store and dispose of according to the applicable regulations HANDLING Eye protection is required Protective gloves chemically resistant boots and apron are recommended FIRST AID...

Страница 15: ...o the bottle When done re assemble the Screw 10 and Stat O Seal 9 TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE LIKELY SOLUTION Piston 7 does not move after depressing Trigger 1 No air supply is connec...

Страница 16: ...ty requirements Assembly power tools for non threaded mechanical fasteners ISO 8662 11 Hand held portable power tools Measurement of vibrations at the handle ISO 3744 Acoustics Determination of sound...

Отзывы: