![Cheminees Philippe RADIANTE 873 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/cheminees-philippe/radiante-873/radiante-873_installation-and-user-manual_2595899014.webp)
FR
EES
TANDING CLEARANCES 3.3
14
CHEMINÉES
PHILIPPE
RADIANTE 873
FREESTANDING
A: CLEARANCES TO 50MM SKAMOL BOARD
CLEARANCES TO A SOLID BRICK/HEBEL VENEER WALL
CLEARANCES TO COMBUSTIBLES
250mm
200mm
700mm
500mm
700mm
1200mm
Hearth
Combustible Wall
Combustible W
all
50mm Skamotec Board
50mm Skamotec Board
50mm
Air
Gap
50mm Air Gap
600mm
500mm
700mm
500mm
700mm
1200mm
Hearth
Combustible Wall
Combustible W
all
50mm Skamotec Board
50mm Skamotec Board
The Skamol boards should extend to a minimum height of 2200mm from the hearth when using a triple skin flue kit OR all
the way to the ceiling when using a single skin flue kit (refer to page 17). When using Skamotec board with a 50mm air
gap behind, it must also be ventilated for natural air flow circulation, (refer to page 15 & 16 for ventilation requirements).
500mm
975mm
700mm
500mm
Hearth
Combustible Wall
Combustible W
all
1150mm
150mm
700mm
500mm
700mm
1200mm
Hearth
Combustible Wall
Combustible W
all
Brick/Hebel
Brick/Hebel
A minimum 110mm solid brick/hebel thick wall should extend a minimum height of 2200mm from the hearth when
using a triple skin flue kit or to the ceiling when using a single skin flue kit.
NON-COMBUSTIBLE CEILING:
For freestanding installations where the ceiling height is
less than 3 metres from the hearth, a non-combustible
board must be used on the ceiling and must extend
1600mm in all directions from the flue outer casing,
unless forming an abutment with a wall. This can be
made of a minimum 8mm cement sheet or equivalent.
GLASS CLEARANCE:
A minimum 1500mm from the front
glass to any combustible surfaces must be maintained.
150mm
CORNER CLEARANCES:
The same rear clearance
as depicted in these illustrations applies from the two
furtherest back corner points of the fireplace to each
corner wall. Base/hearth size remains the same (page 13)
B: CLEARANCES TO 50MM SKAMOL BOARD + AIR GAP
CLEARANCES TO A SOLID BRICK OR HEBEL WALL
700mm
500mm
700mm
1200mm
Hearth
Brick/Hebel
Brick/Hebel
100mm
500mm
100mm
Combustible
Material