Electric Induction hobs Chef’s EH-IH535
30
avaluation. Control
unit cuts off after
3,5-7,5 sec.
discontinuation in the
key of the range
evaluation.
unit.
ER31
Configuration data
incorrect.
Configuration
of
induction necessary.
New configuration
ER36
NTC value is not
within
its
specification (value
< 200mV or > 4,9V
. Control unit Cuts
off).
Short- circuit or cut-
off at NTC.
Exchange control
unit.
ER40
Secondary
operational voltage
is min 5s too low
according
to
identified
unterspannung
(1,8V< Upowerfail
< 2,9V)
Primary PTC too hot.
Disconnect control
unit
from
the
power system .
ER47
Communication
error between TC
and induction.
None
or
faulty
communication.
Ensure
that
connection cable is
plugged
on
corectly and.
U400
Secondary voltage
of the power unit to
high (primary >
300V). control unit
cuts off after 1 sec.
releasing
a
permanent tone.
Control
unit
is
wrongly connected.
Connect to correct
mains voltage.
E2
Overheating of the
induction coils
Cooling
down
necessary.
E5
Error on filter board
Exchage
filter
board.
E6
Error on power unit
Exchange
power
unit
E9
Coil
temperature
sensor defective
Exchange
temperature
sensor.