Chefmate C24CB-SR Скачать руководство пользователя страница 5

Page 5

Unpacking & Installation

INSTALLATION

1.  Read this manual thoroughly before installation and operation.  DO NOT proceed with installation and  

 

 

operation if you have any questions or do not understand everything in this manual.  Contact your local  

 

 

representative or Globe first.

2. 

Select a location for the charbroiler that has a level, solid, nonskid surface that is nonflammable and away

 

from water hazards or sinks, and is in a well-lighted work area away from children and visitors.

3.  Equipment must be installed under proper ventilation as required per local code.

 NOTICE:

 Local codes regarding installation and ventilation vary greatly by area. The National Fire Protection  

 

Association, Inc, states that local codes are “authority having jurisdiction” when it comes to requirements for  

 

installation of equipment. Therefore, installation should comply with all local codes.

4.   Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Legs must  

 

be installed to adequately provide proper ventilation to the unit. 

5.  Level unit by adjusting the four feet and tighten securely. The adjustable feet have an adjustment of one inch 

 

for lineup with other Globe countertop lines. Do not slide unit with legs mounted, lift if necessary to move unit. 

6.  The supplied gas pressure regulator is factory set at 4'' Natural gas W.C. or 10'' for L.P. 

7.  THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.

 

Noncombustible clearances: 6'' sides (152 mm)      6'' rear (152 mm)      4'' floor (102 mm)

8.   Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by 

 

the flue. Do not place objects between the bottom of the unit and the counter top.

9.  There must be adequate clearance for removal of the front panel. All major parts except the burners are

 

removable through the front if the gas line is disconnected.

10. It may be necessary to adjust the balance of gas volume and air supply to each burner. This must be done  

 

by an authorized service technician.

11.  Pipe threading compound must be resistant to the action of liquefied petroleum gases.

DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap 

and water solution before operating unit.

COMMISSIONING:

Commissioning of your new charbroiler is of the utmost importance. Commissioning is the thorough and methodical 

testing of the equipment, sub systems, and systems to ensure that the final product functions properly and safely at 

the work site. By identifying any potential problems (i.e. equipment location, ventilation, local fire/electrical codes, 

installation,  operator  training  and  certification)  prior  to  equipment  being  placed  into  service,  costly  outages  and 

potential damages may be avoided.

                                

        

SAFETY ALWAYS.

Содержание C24CB-SR

Страница 1: ...ip com Slicers Mixers Countertop Cooking Equipment Meat Choppers Scales This manual contains important safety instructions which must be strictly followed when using this equipment IMPORTANT SAFETY NO...

Страница 2: ...RRANTY 12 GLOBE FOOD EQUIPMENT COMPANY 2153 DRYDEN RD DAYTON OH 45439 PHONE 937 299 5493 TOLL FREE 800 347 5423 FAX 937 299 4147 E MAIL info globefoodequip com WEBSITE www globefoodequip com Globe Foo...

Страница 3: ...sonnel come in contact with this equipment Please remember that Globe cannot anticipate every circumstance or environment in which its equipment will be operated It is the responsibility of the owner...

Страница 4: ...e and in accordance with local codes The appliance and its individual shutoff valve to be supplied by user must be disconnected from the gas supply piping system during any pressure testing of that sy...

Страница 5: ...The supplied gas pressure regulator is factory set at 4 Natural gas W C or 10 for L P 7 THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON COMBUSTIBLE SURFACES ONLY Noncombustible clearances 6 sides 15...

Страница 6: ...any parts or attachments and before cleaning Never leave the charbroiler on overnight Do not operate any equipment with a damaged or leaking gas line ignitor or valves or if the unit is dropped or da...

Страница 7: ...pilot valve adjustments Use a screwdriver to turn the valve to adjust the flame height to your desired level Shutdown Turn the unit off by rotating the gas control knob clockwise to the OFF position...

Страница 8: ...e burners A uniform and systematic approach to the loading of the unit will produce the most consistent product results NOTE When the charbroiler is first heated it will smoke until oil used in manufa...

Страница 9: ...loth and a non abrasive cleaner to clean the stainless steel body of the charbroiler Wipe the polished areas with a soft cloth Daily Controls Unit should be turned off when not in use It is recommende...

Страница 10: ...under the unit The catch tray drawer is removed by pulling forward USE CAUTION WHEN REMOVING per Use or at least Daily Burner Air Shutter Openings Main burner ports must be kept clean Close the gas va...

Страница 11: ...area Main gas line leak Turn off main gas valve DO NOT LIGHT FLAME ignite anything or turn switch on anything electrical Call fire department if needed and call for service Cooking surface is heating...

Страница 12: ...PERTY PERSONAL INJURY LOSS OF BUSINESS OR PROFITS OR OTHER ECONOMIC LOSSES OR STATUTORY OR EXEMPLARY DAMAGES WHETHER IN NEGLIGENCE WARRANTY STRICT LIABILITY OR OTHERWISE This warranty is given only to...

Отзывы: