12
How to proceed?
•
Unscrew and remove the
protective cover at the back of the
appliance;
•
Connect the power cable to the
terminal block of the cooker
according to the table no.1;
•
Secure by means of cable
clamp;
•
Make sure that the connection
to the terminal block is matching
the supply system, see table
no.1;
•
Refit and screw the protective
cover on the back of the
appliance.
Table no.1
Rated voltage
415V 3N ~
415V 2N ~
240V
Connection type
Tri-phase Y 3 ph. +
neutral
Bi-phase Y 2 ph. +
neutral
Single phase
Cable connection to the
terminal plate
3
L3
L1
4 5
N
L2
1 2
4 5
N
2 3
L2
L1
1
1 2 3 4 5
L1
N
Network voltage
3N~/415V
2N~/415V
240V
Voltage of heating
elements
240V 240V 240V
Fusible capacity
3 x 16 A
2 x 25 A
35 A
Cable section
5 x 2,5 mm²
4 x 4 mm²
3 x 6 mm²
Содержание CKE5065W