- 35 -
Parameter
Code
Parameter Function
Range / Selection
Unit
Remarks
070.HL
Upper limit of maximum
speed [r/min]
200
~
Limit of the machine
100
The limit value of
【
001.H
】
(maximum sewing
speed)
Depending on the sewing machine model.
071.dir
Direction of motor rotation
CW / CCW
-
CW
:
Clockwise / CCW
:
Counterclockwise
Seen from the motor output-shaft side.
072.GrS
Grease exchange function
selection
ON / OFF
-
ON
:
valid / OFF
:
invalid
Alarm will be displayed if motor run time
becomes the preset value.
073.GrE
Grease exchange function
Forced stop time [hours]
1
~
800
1
Time to forced stop.
When
【
072.GrS
】
is validated.
074.GrW
Grease exchange function
Alarm announce time [hours]
1
~
48
1
Alarm announce time.
When
【
072.GrS
】
is validated.
075.GrP
Grease exchange function
Display the remaining time
[hours]
-
1
Display the remaining time.
When
【
072.GrS
】
is validated.
077.T5
Setting the needle cooling
delay time
[ms]
0
~
2550
10
Setting the needle cooling delay time from
motor stops.
078.NK
Setting the needle cooling
operating point of speed
[r/min]
50
~
6000
10
Needle cooling will operate when sewing
speed excesses this setting value.
079.TrU
Motor stops with a rotation
angle after trimming
ON / OFF
-
ON
:
valid / OFF
:
invalid
When it turns ON, machine rotates
automatically after trimming.
080.Trd
Direction of rotation of
“Motor stops with a rotation
angle after trimming”
0 / 1
-
0
:
Reverse rotation / 1
:
Forward rotation
Valid only when
【
079.TrU
】
= ON.
081.Tr8
Angle of rotation of
“Motor stops with a rotation
angle after trimming”
[degree]
0
~
180
1
Valid only when
【
079.TrU
】
= ON.
082.Trv
Speed of rotation of
“Motor stops with a rotation
angle after trimming”
[r/min]
200
~
300
10
083.bTP
Type selection for
output of Back-Tack
M / A
-
M
:
Magnetic type.
A
:
Air type.
When set at A type,
【
084.bKo
】
and
【
085.bKC
】
setting will be invalid.
It will be full on.
084.bKo
Full-On time setting for
output of Back-Tack
[ms]
0
~
990
1
Valid only when
【
083.bTP
】
= M.
085.bKC
Duty-Cycle setting for
output of Back-Tack
[%]
10
~
90
1
Valid only when
【
083.bTP
】
= M.
086.FTP
Type selection for
output of Foot lifter
M / A
-
M
:
Magnetic type.
A
:
Air type.
When set at A type,
【
087.Fo
】
and
【
088.FC
】
setting will be invalid.
It will be full on.
087.Fo
Full-On time setting for
output of Foot Lifter [ms]
0
~
990
1
Valid only when
【
086.FTP
】
= M.
088.FC
Duty-Cycle setting for
output of Foot Lifter
[%]
10
~
90
1
Valid only when
【
086.FTP
】
= M.
089.Fd
Running-Delay time setting
[ms]
0
~
990
5
The time after foot lifter down until motor starts.
090.FPM
Protection for
foot lifter solenoid
ON / OFF
-
ON
:
The foot lifting solenoid activated time
will be controlled by
【
091.FP
】
.
OFF
:
The foot lifting solenoid will be always
active unless heeling back the pedal.
GOLDEN WHEEL