- 31 -
Parameter
Code
Parameter Function
Range / Selection
Unit
Remarks
049.T
Thread trimming speed
[r/min]
150
~
300
10
050.AFM
Mode selection for
Automatic Foot Lifter
0 / 1 / 2 / 3
-
0
:
Foot Lifter down at machine stop,
Foot Lifter down after trimming.
1
:
Foot Lifter up at machine stop,
Foot Lifter down after trimming.
2
:
Foot Lifter down at machine stop,
Foot Lifter up after trimming.
3
:
Foot Lifter up at machine stop,
Foot Lifter up after trimming.
051.nUd
Needle position
at machine stop
UP / DN
-
UP
:
UP_position
DN
:
DOWN_position
053.SL
Slow start function selection
ON / OFF
-
ON
:
valid / OFF
:
invalid
054.S
Slow start speed
[r/min]
200
~
3000
100
Attainment speed at slow start.
055.SLS
Stitch numbers for
slow start [stitches]
0
~
10
1
Slow start stitches setting.
056.CUd
Count mode selection
(The real number of
stitches or trimming
= the value of
【
057.Cnr
】
×
【
058.Ud
】
)
NOP / U / D / US
/ DS / UT / DT
/ UTS / DTS
-
NOP
:
The counter is invalid.
U
:
Count up by stitches.
D
:
Count down by stitches.
US
:
Count up by stitches.
When count over, motor stops.
DS
:
Count down by stitches.
When count over, motor stops.
UT
:
Count up by trimming.
DT
:
Count down by trimming.
UTS
:
Count up by trimming.
When count over, motor stops.
DTS
:
Count down by trimming.
When count over, motor stops.
057.Cnr
Counter ratio selection
1
~
100
1
058.Ud
Setting the count
[count]
1
~
9999
1
059.TK3
Warning buzzer of counter
announcement timing
[count]
0
~
250
1
Valid only when
【
056.CUd
】
= US / DS.
Effective when external panel connected.
060.Pn
Display the current count
[count]
0
~
9999
1 Press
(1000th) key to reset the counter.
062.Pdc
Pedal curve
0 / 1 / 2
-
The size of the curve of the speed changes
for the pedal toe down amount can be set.
When the preset value is large, inclination
of speed change becomes large.
064.SP
Display the current
Sewing speed [r/min]
-
-
GOLDEN WHEEL