![Checkmate ecoAnch2or Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/checkmate/ecoanch2or/ecoanch2or_user-manual_2595008006.webp)
User Manual
Page 6
Issue 3
ecoAnch
ecoAnch
2
2
or
or
®
Section 3.1
Section 3.1
1.
Remove from carry bag, unfold & position the
anchor so as to maximize the contact area
between the base of the anchor & the roof.
2.
Avoid areas where there are projections, e.g.
bolts, ridges etc.
Do not position the anchor in
areas where water accumulates.
3.
The anchor must be positioned as indicated
on the label with the vent at the highest corner &
the drain at the lowest point. The vent allows air
to escape & prevents the over-pressurising.
Incorrect positioning can result in trapped air &
underfilling, making the anchor unsafe.
4.
The anchor is filled with cold water by simply
fitting a hose with an outside diameter of 16mm
to 20mm into the filler spout with the rubber
bung removed. Filling is complete when water
begins to flow from the diagonally opposite vent
valve.
To detach the hose, squeeze the spout, remove
the hose & replace the bung.
The anchor should now be completely full of
water, any air that can be felt in the bag can be
exhausted through the vent.
Installation & System Setup
Installation & System Setup
Содержание ecoAnch2or
Страница 1: ...User Manual ...