Checkmate ecoAnch2or Скачать руководство пользователя страница 4

User Manual

Page 4

Issue 3

ecoAnch

ecoAnch

2

2

or

or

®

Section  2.0

Section  2.0

Storage in a central protected location allows assurance of inspection on issue and return.
This device should be stored in a clean dry place where it can be protected from damage by chemical attack and

sharp objects . It should be stored with its instructions and record card at all times.
Return the device back to it’s original holdall for storage & transportation.

After use return to the store, Never leave the device lying around site.

This and associated equipment must be visually inspected by a competent person when initially delivered to site,

there after the product must be inspected before and after use. A record card is printed on the page 10 of this

manual and should be completed when first put into service, and updated after each routine inspection. Follow the

points laid down in the section headed “Inspection” without deviation.
The supervisor must ensure that the equipment is being used correctly and that the user is aware of its safe use

and inspection.

Inspect the device for damage or leakage.

Inspect the attachment point for signs of wear or damage.

If in doubt quarantine and remove from service.

Check the user instructions are clear & legible.

To clean the anchor, a mild detergent can be used with warm or cold water & left to dry naturally before storing.

Ensure that device certification is current before use, the device must have been serviced within the

last 12 months and 6 months if used in corrosive or off-shore environments

.

If  for  any  reason  the  inspection  of  this  device  shows  signs  for  concern  or  doubt  then  the  device  must  be

quarantined and removed from service immediately. Qualification should be sought from the supervisor and if still

concerned the device must be sent to the supplier, an approved service agent or the manufacturer for service and

re-calibration.

This device must only be serviced by a trained and competent individual, 

Never attempt to service this unit or tamper with its function in any way.

The ecoAnch

2

or

®

has an expected life or at least five years exposed, and significantly longer wrapped up and

stored correctly in the bag.  The lifespan is dependant upon regular and correct inspection, but is estimated to be
a minimum of five years from when it was first put into service.

Storage, Issue & Inspection

Storage, Issue & Inspection

Storage

Inspection

Issue

Lifespan

Содержание ecoAnch2or

Страница 1: ...User Manual ...

Страница 2: ...r or Index Index Page Page 1 0 Introduction to ecoAnch2or Scope of Use 2 0 Storage Issue Inspection Lifespan 3 0 Installation and System Setup 4 0 Anchorage Compatibility Warnings 5 0 Quality Legislation Exclusions 6 0 Record Card 3 4 5 7 8 9 10 11 ...

Страница 3: ... tested exceeds the EN795 Class E standard even works on roof pitches to 15 degrees For a full list of approved surfaces roof angles please see ecoAnch2or supplement available on request from Checkmate The anchor is safe to use on wet surfaces but NOT shiny or slippery surfaces When collapsed the ecoAnchor weighs just 8Kg fits into to a small holdall for easy installation Introduction to the Intro...

Страница 4: ...t the attachment point for signs of wear or damage If in doubt quarantine and remove from service Check the user instructions are clear legible To clean the anchor a mild detergent can be used with warm or cold water left to dry naturally before storing Ensure that device certification is current before use the device must have been serviced within the last 12 months and 6 months if used in corros...

Страница 5: ... EPDM membrane Felt chippings loose chippings must be removed For a full list of approved surfaces roof angles please see ecoAnch2or supplement available on request from Checkmate Before use ensure that the surface you are working on is capable of supporting the weight of the anchor The weight of the anchor when full is 430kg with a distributed load of 273kg per square metre Inspect the anchor for...

Страница 6: ...est point The vent allows air to escape prevents the over pressurising Incorrect positioning can result in trapped air underfilling making the anchor unsafe 4 The anchor is filled with cold water by simply fitting a hose with an outside diameter of 16mm to 20mm into the filler spout with the rubber bung removed Filling is complete when water begins to flow from the diagonally opposite vent valve T...

Страница 7: ... taut If neccessary refill the bag until water is seen to come out of the vent After Use 6 Empty the bag by unscrewing the drain cap When almost empty lift the the bag to remove the remaining water 7 If the external surface of the bag is wet leave to dry before folding 8 Fold twice as shown in photo carefully expelling any remaining air until relatively flat 9 Roll lengthways until compressed into...

Страница 8: ... as the Checkmate PBH range Suitable lanyards for connection are Type SAL PAL and RL2 This unit is not suitable for use in explosive environments If in doubt contact your approved Checkmate technical support for further details Warnings Read and understand manufacturers instructions before inspection installation or use of this product Never use this product if you weigh more than 100kg Only use a...

Страница 9: ...n and written exams are completed before full certification can be given to installers 5 2 Legislation and Standards The ecoAnchor has been designed to meet BS EN 795 Class E For clarification on any certification issues contact Checkmate or SGS UK 5 3 Exclusions Checkmate holds global product liability cover for your safety Checkmate will NOT however be responsible for a users who are out of the ...

Страница 10: ...Issue 3 ecoAnch ecoAnch2 2 or or Section 6 0 Section 6 0 DATE DATE USER USER Record Card Record Card SERIAL NO SERIAL NO PRODUCT CODE PRODUCT CODE DATE DATE CONDITION OF SYSTEM CONDITION OF SYSTEM INSPECTED INSPECTED BY BY ...

Страница 11: ...User Manual Page 11 Issue 3 ecoAnch ecoAnch2 2 or or Section 6 0 Section 6 0 Record Card continued Record Card continued DATE DATE CONDITION OF SYSTEM CONDITION OF SYSTEM INSPECTED BY INSPECTED BY ...

Страница 12: ...Approved service company Checkmate Lifting Safety LLP Sheerness Kent England ME12 1PZ UK Tel 44 0 1795 580333 Fax 44 0 1795 668280 sales checkmateuk com www checkmateuk com ...

Отзывы: