– 7 –
G. Small 7 Segment: The material velocity, speed the sound wave travels through a
given medium/material, is displayed in this area, informing the user what material
the TI-25DLX is currently calibrated too. This area is also used for alpha messages
in the menu and edit modes.
H. Units: This combination of icons are illuminated in different sequences to inform
the user what measurement units are currently being displayed in the small 7
segment area.
I. Small 14 Segment: Displays the current gain setting of the TI-25DLX . MED is the
default, with the options of VLOW, LOW, MED, HIGH, VHI (40dB to 52db gain
range with MED at 46dB).
J. Units: This combination of icons are illuminated in different sequences to
inform the user what measurement units are currently being displayed in the
large 7 segment area.
K. Small 14 Segment: The material type is displayed in this area. If it is set to a
value of one of the materials in our material list, it will be displayed in alpha
characters indicating the material type. Otherwise it will be set to CUST, indicating
custom material type.
L. Features: The icons illuminated in this row across the bottom of the LCD display
which features are currently enabled. For a complete list of the menu features in
the TI-25DLX , Refer to section 2.0 for a list. The TI-25DLX can be locked once
calibrated, to avoid accidently changing the calibration. When this icon is
illuminated, the TI-25DLX is in lock mode. Refer section 6.7 for an explanation on
locking the TI-25DLX .
M. FILE LOC: This area is exclusively for the data storage section of theTI-25DLX.
The icons and segment fields represent the current file open, and the current storage
location in the file. Refer to section 8.0 for an explanation of the data storage feature
in the TI-25DLX.
2.10 The Transducer
The transducer is the “business end” of the TI-25DLX . It transmits and receives
ultrasonic sound waves that the TI-25DLX uses to calculate the thickness of the
material being measured. The transducer connects to the TI-25DLX via the attached
cable, and two coaxial connectors. When using transducers manufactured by Checkline,
the orientation of the dual coaxial connectors is not critical: either plug may be fitted to
either socket in the TI-25DLX .