Customer Replaceable Parts
Smart-1 Hardware
Page 37
5. Make sure that the additional hard drives have been inserted correctly and are recognized by the system
by running the command
/sbin/raidconfig status
6. Stop all Check Point processes by running
cpstop
or
mdsstop
7. Stop all other processes that are using
/var/log
. To see a list of these processes, run
lsof
/var/log
8. Add the additional storage to the file system by running the command
/sbin/raidconfig extendstorage
In the event that the storage extension process fails:
1. Run the command
/opt/MegaRAID/MegaCli/MegaCli –CfgForeign -Clear -a0
2. Repeat steps 5 to 8 above.
Verifying Hard Drive Extension
1. Run the
/sbin/raidconfig status
command to view the status of the hard disk drives. Additional
hard disk drives should appear configured in additional four discs’ RAID 10 arrays.
2. Run the
lvdisplay /dev/vg_splat/lv_log
command. The additional storage should appear
available under this logical volume.
Cooling Fans
The Smart-1 appliance contains three cooling fans. Each cooling fan operates independently of the other(s),
providing redundancy in the event of failure.
This section presents the procedures for removing and installing a fan unit. It is not necessary to power off
the appliance before adding or removing a fan unit.
Removing Fan Units
To remove a fan unit:
1. Loosen the retaining screws in the corners of the fan assembly.
2. Gently pull the fan unit out of the appliance.
Installing Fan Units
To install a fan unit:
1. Insert the fan unit into the appliance. Push firmly until it clicks into place.
2. Tighten the retaining screws in the corners of the fan assembly.