background image

Configuring Smart-1 Appliances

Quantum Smart-1 600-M Appliances Getting Started Guide   |   10

Configuring Smart-1 Appliances

Starting the Appliance

Connect the appliance to a power source and turn on the appliance. When the appliance is ready, you can
run the First Time Configuration Wizard to configure it.

To start the appliance:

1.

Connect the appliance's management interface to a PC with the included Ethernet cable.

2.

Connect both power cables to the power supply units in the rear panel.

3.

If the power did not come up, press the

Power

button to power it up.

4.

The appliance turns on.

When the appliance is ready, you can run the First Time Configuration Wizard to configure it.

Available Software Images

The Smart-1 600-M appliance comes with the R81 software image.

To follow the installation progress and see when the appliance is ready, connect to the appliance with a
serial console cable.

For more about software images, see the

Smart-1 600-S/600-M/6000-L/6000-XL home page

.

Initial Configuration

Configure the appliance with the Gaia First Time Configuration Wizard. See the

Quantum Smart-1

Appliances Quick Start Guide

provided with your appliance.

Advanced Configuration

You can configure advanced options on Gaia OS from the Gaia Portal or the Gaia Clish.

Connecting to the Smart-1 Appliances CLI

To connect to the command line interface of the Smart-1 Appliances, use one of these:

n

Use the included serial console cable (DB9-to-DB9), or the DB9-to-RJ-45 adapter, and a terminal
emulation software, such as PuTTY (from Windows) or Minicom (from Unix/Linux).

n

Use an SSH connection to the management interface (if SSHD is configured).

Содержание QUANTUM SMART-1

Страница 1: ...Classification Protected 13 April 2021 QUANTUM SMART 1 600 M APPLIANCES Getting Started Guide...

Страница 2: ...recaution has been taken in the preparation of this book Check Point assumes no responsibility for errors or omissions This publication and features described herein are subject to change without noti...

Страница 3: ...ations For third party independent certification of Check Point products see the Check Point Certifications page Check Point Quantum Smart 1 600 M Appliances For more about this release see the home p...

Страница 4: ...ion 10 Advanced Configuration 10 Connecting to the Smart 1 Appliances CLI 10 Configuring SmartEvent 12 Smart 1 Appliances Hardware 13 Smart 1 600 M Front Panel 13 Storage Devices 14 Smart 1 600 M Rear...

Страница 5: ...r the qualified electricians only 29 Ergonomic Instructions 29 Environmental considerations 30 ENERGY STAR for servers 30 Battery disposal 30 Battery directive 30 Waste Electrical And Electronic Equip...

Страница 6: ...600 M Appliances Getting Started Guide 6 Safety Environmental and Regulatory Information Before you begin to install the appliance read the content in the Enterprise Products Safety Environmental and...

Страница 7: ...the 6th generation of Cyber Security The Smart 1 600 M dedicated appliance is optimized for performance and scalability with both hardware and OS operating system hardened from the core Check Point In...

Страница 8: ...pliance One Smart 1 600 M appliance Rails box n Telescopic Rails Kit 1U Doc Kit Documentation n Enterprise Products Safety Environmental and Regulatory Information booklet n Quick Start Guide n Instal...

Страница 9: ...ted installation procedures Appliance Air Vents Make sure that the appliance air vents have sufficient airflow from front to rear when the appliance is mounted in a rack Important If the appliance ven...

Страница 10: ...600 M appliance comes with the R81 software image To follow the installation progress and see when the appliance is ready connect to the appliance with a serial console cable For more about software...

Страница 11: ...9 to RJ 45 adapter screws to the Serial console port 3 Connect the RJ45 end of the serial console cable to the RJ45 port on the DB9 to RJ 45 adapter 4 Connect the other end of the serial console cable...

Страница 12: ...600 M Appliances Getting Started Guide 12 Configuring SmartEvent To learn how to connect the SmartEvent components to a Security Management Server and to a Multi Domain Server see the Logging and Mon...

Страница 13: ...error messages contact Check Point Support 2 Power on indicator Power button Lets you know the power status of the system The power on indicator glows when the system power is on The power button con...

Страница 14: ...D Level 1 Supported RAID Levels 1 Default Storage 2 x 4TB disks Optional Storage N A Important If you configure RAID these are the only supported settings Numbering of the Disk Slots on the Smart 1 60...

Страница 15: ...ondition Steady green Disk is online Flashes green twice per second Identifying disk or preparing disk for removal Blinks green amber and then turns off Predicted disk failure Blinks amber four times...

Страница 16: ...ance connects to the network Ethernet ports 1 2 and 3 See Integrated NIC LEDs on the next page n Manage the appliance MGMT port 5 Power supply units For more information about the PSU configurations s...

Страница 17: ...s data rate is selected 2 Activity LED Off Link off No connectivity the port is turned off or link is on without traffic Blinking green Link is on with traffic Expansion Line Card LEDs The line card h...

Страница 18: ...d Upgrading Components The Smart 1 Appliances has parts that you can easily replace to minimize downtime There are also components that you can install to upgrade the appliance These are the parts and...

Страница 19: ...lerant RAID configurations one or more disk failures do not result in data loss Smart 1 600 M supports mirrored disks RAID 1 The RAID level is set initially as a default When a faulty disk is replaced...

Страница 20: ...connecting to the Console port with a Terminal emulation program For more about the Hardware Diagnostic Tool see sk97251 To run the Hardware Diagnostic Tool 1 Connect the supplied DB9 serial cable to...

Страница 21: ...t navigation tree click Maintenance Factory Defaults The Factory Defaults window opens 4 Select the image version to restore 5 Click Apply The appliance reboots and installs the selected version from...

Страница 22: ...Y select the Serial connection type n In the HyperTerminal Connect To window select a port from the Connect using list 4 Define the serial port settings 9600 BPS 8 bits no parity 1 stop bit 5 From the...

Страница 23: ...MT_interface mac addr 5 Copy the MAC address from the screen To find the MAC address of the Management Interface in Gaia Portal 1 In your web browser connect to the management IP address https applian...

Страница 24: ...ing Started Guide 24 Support For additional technical information about Check Point products consult the Check Point Support Center Where To From Here You have the basics to get started The next step...

Страница 25: ...Dell Way Round Rock TX 78682 USA Date first applied 20 Aug 2018 The equipment described above has been assessed and found in compliance with the following harmonized standards regulations and technic...

Страница 26: ...tential for property damage personal injury or death n The power supply units PSUs in your system may produce high voltages and energy hazards Opening or removing covers that are marked with the trian...

Страница 27: ...non rack mounted servers leave 10 2 cm 4 in minimum of clearance on all vented sides of the equipment to permit the airflow required for proper ventilation Restricting airflow can damage the equipment...

Страница 28: ...ith any other rack n Before installing your equipment in a rack install all front and side stabilizers Failure to install stabilizers can allow the rack to tip over n Always load from the bottom up an...

Страница 29: ...t the power is removed from the DC circuit To ensure that the power is off locate the circuit breaker on the DC source circuit usually at the power distribution fuse bay Switch the circuit breaker to...

Страница 30: ...ose the battery along with household waste Contact your local waste disposal agency for the address of the nearest battery deposit site Battery directive In the European Union this label indicates tha...

Страница 31: ...ire special handling when recycled or disposed See www dtsc ca gov hazardouswaste perchlorate Regulatory notices For additional regulatory information see the Regulatory Compliance homepage at http ww...

Страница 32: ...utput I O devices monitors and so on that are integrated into or connected to the system should match the electromagnetic environment classification of the computer system A Notice About Shielded Sign...

Страница 33: ...uiry please use the following contact information Dell Inc Worldwide Regulatory Compliance Engineering and Environmental Affairs One Dell Way PS4 30 Round Rock Texas 78682 USA 512 338 4400 Industry Ca...

Страница 34: ...ion of Conformity in accordance with the preceding directives and standards has been made and is on file at Dell Inc Products Europe BV Limerick Ireland For Enterprise Products Safety Environmental an...

Отзывы: