Korg Polysix MIDI Interface
Korg Polysix MIDI Interface
Korg Polysix MIDI Interface
Korg Polysix MIDI Interface
P6
P6
P6
P6----M
M
M
M Owner‘s
Owner‘s
Owner‘s
Owner‘s Manual
Manual
Manual
Manual
8
88
8----427 / v. 1.00
427 / v. 1.00
427 / v. 1.00
427 / v. 1.00
Copyright © 2021 CHD Elektroservis. All rights reserved.
No part of this publication may be reproduced in any form without the written permission of CHD Elektroservis.
11
11
11
11
Table 3
Table 3
Table 3
Table 3 –
––
– Additional LFO waveforms
Additional LFO waveforms
Additional LFO waveforms
Additional LFO waveforms –
––
– continue
continue
continue
continue
Param.
Param.
Param.
Param.
value
value
value
value
LFO waveform
LFO waveform
LFO waveform
LFO waveform
Param.
Param.
Param.
Param.
value
value
value
value
LFO waveform
LFO waveform
LFO waveform
LFO waveform
10
Square 25%
37
Sine
11
Square 37,5%
38
Sine 2nd Harmonics
12
Square 50%
39
Sine 3rd Harmonics
13
Square 62,5%
40
3 Stairs Up
14
Square 75%
41
3 Stairs Down
15
Square 87,5%
42
4 Stairs Up
16
Trapezoid 25%
43
4 Stairs Down
17
Trapezoid 37,5%
44
5 Stairs Up
18
Trapezoid 50%
45
5 Stairs Down
19
Trapezoid 62,5%
46
Exp
20
Trapezoid 75%
47
Exp Inverted
21
Pulse 12,5%
48
Log
22
Pulse 25%
49
Log Inverted
23
Pulse 37,5%
50
Noise 1
24
Pulse 50%
51
Noise 2
25
Pulse 62,5%
52
Noise 3
26
Pulse 75%
53
Noise 4
27
Peak 25%
54
Noise 5
28
Peak 37,5%
55
Groove 1
29
Peak 50%
56
Groove 2
30
Peak 62,5%
57
Groove 3
31
Peak 75%
58
Groove 4
32
Sink 25%
59
Groove 5
33
Sink 37,5%
60
Groove 6
34
Sink 50%
61
Groove 7
35
Sink 62,5%
62
Groove 8
36
Sink 75%
63
Random
The Groove waveforms (parameter values 55 to 62) simulate a rhythmic sequences for the VCF modulation.
They are primarily designed for synchronization with MIDI Clock (chapter 4.2.8) and for lower speeds of the LFO
(chapter 4.2.9). The Random waveform (parameter value 63) works standard way – it periodically sets random
level of the VCF cutoff frequency.
4.2.8
4.2.8
4.2.8
4.2.8 VCF LFO SYNC (CC #23)
VCF LFO SYNC (CC #23)
VCF LFO SYNC (CC #23)
VCF LFO SYNC (CC #23)
The parameter selects synchronization mode for the additional software LFO. It can be temporarily changed by
MIDI CC Nr. 23 - see chapter 5.1.2.2.
The parameter value is 0 to 3. Four synchronization modes are available (see fig. 10):
•
0
0
0
0
Æ
Æ
Æ
Æ
Fixed:
Fixed:
Fixed:
Fixed: The additional software LFO rate is controlled by interface clock generator. The fixed tempo is set
by VCF LFO RATE parameter directly (see chapter 4.2.9 and table 10 in chapter 6.5).
•
1
1
1
1
Æ
Æ
Æ
Æ
MIDI:
MIDI:
MIDI:
MIDI: The rate of the additional software LFO is derived from the external MIDI Clock
9
99
9
. Frequency of
incoming MIDI Clock is divided - dividing ratio is selected by VCF LFO RATE parameter (see chapter 4.2.9 and
table 10 in chapter 6.5).
9
Transmitting of MIDI Clock must be enabled in your DAW / sequencer! Maximal allowed tempo (BPM) is limited – see table 10.
Содержание 8-427
Страница 32: ......