3.2
Configuring the Rover Station via LandStar 7
Software
3.2.1
Receiving Static Data
(1)
Power on the receiver.
(2)
Run LandStar 7 on the controller → create a new project or open an existing
project → establish the connection with the receiver via Bluetooth.
(3)
On the
Static Setting
screen, set parameters as need and then click
Set
to finish.
3.2.2
Receiving Corrections Using Cellular Modem in the
Controller
(1)
Power on the receiver.
(2)
(3)
Run LandStar 7 on the controller → create a new project or open an existing
project → establish the connection with the receiver via Bluetooth.
(4)
On the
Work Mode
screen, choose
PDA Network
as
Datalink
;
Ntrip
as
Protocol
.
(5)
Input or choose the corresponding
Ntrip IP
and
Port
, and then, click download
icon
to get the source table.
(6)
Click the location icon at the end of source table row; users can have a view of the
distance between current position and a single station in source table interface.
Given this table, users can choose the closest single station.
(7)
Input
User Name
and
Password
.
(8)
Configure the related parameters from the dropdown list or enter the value with
the soft keyboard:
Data Format
,
Elevation Mask
,
PDOP Limit
,
Safe Mode
and
Iono Condition
.
Note
: Select the Data Format the same as that of the base receiver. Turning on or
off of RTCM 1021-1027 messages depend on messages from the mount point and
user’s need.
(9)
Click
Save
and give a name to this work mode. Then, accept the work mode.
Users can conduct surveying work after the rover receiver receives correction
data (with correction LED flashes once per second) and gets a fixed solution.