background image

Vue™ 1.1 User Manual 

Rev. 4 

Not all fixtures have a 
voltage select switch. 
Please be sure to connect 
to the proper voltage. 

1.

 

B

EFORE 

Y

OU 

B

EGIN

 

What is Included 

Ø

 

1 x Vue™1.1 

Ø

 

1 x Power Cord 

Ø

 

1 x Warranty Card 

Ø

 

1 x User Manual 

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all 
parts are present, and have been received in good condition. Notify the shipper immediately and retain 
packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs 
of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to 
the factory, it is important that the fixture be returned in the original factory box and packing. 

AC Power 

To determine the power requirements for a particular fixture, see the label 
affixed to the back plate of the fixture or refer to the fixture’s specifications 
chart. A fixture’s listed current rating is its average current draw under 
normal conditions. All fixtures must be powered directly off a switched 
circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, 
even if the rheostat or dimmer channel is used solely for a 0% to 100% 
switch. Before applying power to a fixture, check that the source voltage 
matches the fixture’s requirement. Check the fixture or device carefully to 
make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use. 

Warning! 

Verify that the voltage select switch on your unit matches the line voltage applied. Damage to your 
fixture may result if the line voltage applied does not match the voltage indicated on the voltage 
selector switch.  

 
 

All fixtures must be connected to circuits with a suitable Earth Ground.  

Safety Instructions 

 

 

Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that they 
also receive this instruction booklet. 

 

Always make sure that you are connecting to the proper voltage, and that the line voltage you are 
connecting to is not higher than that stated on the decal or rear panel of the fixture. 

 

This product is intended for indoor use only! To prevent risk of fire or shock, do not expose fixture to rain or 
moisture. 

 

Make sure there are no flammable materials close to the unit while operating. 

 

The unit must be installed in a location with adequate ventilation, at least 20 in (50 cm) from adjacent 
surfaces. Be sure that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or replacing lamp or fuse and be sure to replace 
with same lamp source. 

 

Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its 
carrying handles. 

 

Maximum ambient temperature (Ta) is 104° F (40° C). Do not operate fixture at temperatures higher than 
this.  

 

In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by 
yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the 
nearest authorized technical assistance center.  

 

Never connect the device to a dimmer pack. 

 

Make sure the power cord is never crimped or damaged. 

 

Never disconnect the power cord by pulling or tugging on the cord. 

 

Avoid direct eye exposure to the light source while it is on.  

Caution! 

There are no user-serviceable parts inside the unit. Do not open the housing or attempt 
any repairs yourself. In the unlikely event your unit may require service, please contact 
CHAUVET® at: 954-577-4455. 

 

 

Please read these instructions carefully, which includes important 
information about the installation, usage and maintenance of this product. 

Содержание Vne 1.1

Страница 1: ... Sunrise FL 33351 U S A 800 762 1084 954 577 4455 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave 120 230 V switch Replaceable Fuse User Serviceable ...

Страница 2: ... 5 FUSE REPLACEMENT 6 FIXTURE LINKING 6 DMX Data Cable 6 MASTER SLAVE FIXTURE LINKING 6 MOUNTING 6 Orientation 6 Rigging 6 4 Operating Instructions 7 STANDALONE MODE SOUND ACTIVE AUTO MODE 7 DMX MODE 7 DMX Channel Values 7 Setting the Starting Address 8 DMX QUICK REFERENCE CHART 9 DMX Address Quick Reference Chart 9 GENERAL TROUBLESHOOTING 10 5 Appendix 11 GENERAL MAINTENANCE 11 RETURNS 11 CLAIMS ...

Страница 3: ...ected to circuits with a suitable Earth Ground Safety Instructions Please keep this User Manual for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture Thi...

Страница 4: ... LEDs Built in automated programs via master slave or DMX Built in sound activated programs via master slave or DMX ADDITIONAL FEATURES Linkable with Vue 1 1 Vue 2 1 and Vue 6 1 Adjustable hanging bracket with slide rail DMX Channel Summary CHANNEL FUNCTION 1 Control Operating Mode 2 Red 3 Green 4 Blue 5 Strobing Speed Stand alone Speed 6 Dimmer ...

Страница 5: ...Vue 1 1 User Manual 5 Rev 4 Product Overview DMX output Hanging Bracket Fuse holder Sound sensitivity Bracket Adjustment knob Dipswitches Front Lens DMX input Voltage selection switch ...

Страница 6: ...le Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable will have the following characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 pF ft Maximum capacitance between conductor and shield 55 pF ft Maximum resistance of 20...

Страница 7: ... recognize master slave operation when connected properly The first fixture will be set as the master and all fixtures following this will set as slave fixtures You must follow daisy chain configuration for this type of setup Note Do not connect a DMX controller to the fixture s when you are trying to run them standalone as this will put them in DMX mode automatically DMX Mode This mode allows the...

Страница 8: ... start address Turn this switch on 2 Subtract the value of the switch you just turned on from the starting address number 3 Determine the largest value switch that is less than the remainder from the previous subtraction Turn this switch on 4 Subtract the value of the switch you just turned on from the remainder of the previous subtraction 5 Repeat steps three and four until you have a remainder o...

Страница 9: ...428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 21...

Страница 10: ...eck for power on Mains Check device s fuse internal and or external ü ü ü Fixture is not responding Check DMX Dip switch settings for correct addressing Check DMX cables Check polarity switch settings ü Fixture is on but there is no movement to the audio Make sure you have the correct audio mode on the control switches If audio provided via jack make sure a live audio signal exists Adjust sound se...

Страница 11: ...dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Returns Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CHAUVET and request RMA prior to shipping t...

Страница 12: ...rature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols USITT DMX512 A DMX Channels 6 ORDERING INFORMATION Vue 1 1 VUE1 1 WARRANTY INFORMATION Warranty 2 year limited warranty Contact Us Worldwide General Information CHAUVET Lighting 5200 NW 108th Avenue Sunrise FL 33351 voi...