background image

 
4. Operating Instructions 

Rev. 2 

 

4.

 

O

PERATING 

I

NSTRUCTIONS

 

Configuring the Starting Address 

Each fixture requires a starting address from 1~512. A fixture requiring one or more channels for control begins 
to read the data on the channel indicated by the starting address. For example, a fixture that uses seven DMX 
channels and is addressed to start on DMX channel 100, will read data from channels: 100, 101, 102, 103, 104, 
105 and 106. Choose the starting addresses for each fixture so that the channels used do not overlap. In 
addition, you should note the starting address selected for future reference. The Trident™ fixture uses 3 DMX 
channels.  

DMX Operation 

This is the operating mode which will allow for control with an external DMX controller. You must set the starting 
address for this mode. If you are unfamiliar with DMX, download the DMX Primer from 

www.chauvetlighting.com

.  

 

1. 

Plug the fixture into power. 

2. 

Connect DMX cable(s) to controller. 

3. 

Turn DIP switch [10] to the ON position. 

4. 

Use DIP switches 1~9 to set the starting address. 

Master/Slave 

This is the operating mode which will allow 1 fixture to act as the “master” and control all of the other “slave” 
fixtures. You must set both the master and the slave(s) fixtures to the correct mode for this operation. They 
must also be connected using DMX cables, in a daisy chain fashion. 
 

Master Settings: 

 

1. 

Using the DIP switches, set the master fixture to one of the following modes: custom, automatic, 
or sound-activated. 

 

Slave Settings: 

1. 

Turn DIP switch [10] to the ON position. 

2. 

Turn DIP switches 1~9 to the OFF position. 

 

 

Do not connect a DMX controller to the daisy chain for this operation. 

 

Standalone Operation 

Automatic 

This fixture has a preprogrammed chase. This is accessed via the DIP switches: 

 

1. 

Plug the fixture into power. 

2. 

Turn DIP switch [8] to the ON position. 

3. 

Turn all other DIP switches to the OFF position. 

 

 

Do not connect a DMX controller to the daisy chain for this operation. 

 

Sound-Active 

This fixture has a preprogrammed sound triggered chase. This is accessed via the DIP switches, and the 
speed may be adjusted using the audio adjustment knob. Please see the instructions below for further 
explanation. 
 

1. 

Plug the fixture into power. 

2. 

Turn DIP switch [9] to the ON position. 

3. 

Turn all other DIP switches to the OFF position. 

 

Do not connect a DMX controller to the daisy chain for this operation. 

 

 

 

Содержание TRIDENT

Страница 1: ...L 33351 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Auto ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Страница 2: ...N 7 MASTER SLAVE 7 STANDALONE OPERATION 7 Automatic 7 Sound Active 7 Custom Program 8 DMX CHANNEL VALUES 8 DIP SWITCH VALUES 8 5 APPENDIX 9 GENERAL MAINTENANCE 9 POWER LINKING 9 SETTING THE STARTING ADDRESS 9 GENERAL TROUBLESHOOTING 10 RETURNS 11 CLAIMS 11 TECHNICAL SPECIFICATIONS 12 CONTACT US 12 CHAUVET 2012 All Rights Reserved Information and specifications in this User Manual are subject to ch...

Страница 3: ...te certain types of information from the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A val...

Страница 4: ...Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Never connect the device to a dimmer pack Make sure the power cord is never crimped or ...

Страница 5: ...oduction 5 Rev 2 Product Overview Safety attachment point Hanging bracket Fuse holder Power in Power out DMX in DMX out DIP switches Microphone Microphone sensitivity adjustment knob Back Panel A Back Panel B ...

Страница 6: ...e The maximum quantity of fixtures that may be linked is 26 Mounting Orientation The Trident may be mounted in any safe position provided there is adequate room for ventilation Rigging Be sure that the structure can support the weight of the fixture Mount the product securely This may be done with a screw nut and bolt or a hanging clamp Be sure to also use a safety cable The hole in each bracket i...

Страница 7: ...which will allow 1 fixture to act as the master and control all of the other slave fixtures You must set both the master and the slave s fixtures to the correct mode for this operation They must also be connected using DMX cables in a daisy chain fashion Master Settings 1 Using the DIP switches set the master fixture to one of the following modes custom automatic or sound activated Slave Settings ...

Страница 8: ...r to rotate CW CCW at a preset speed This may not be altered Do not connect a DMX controller to the daisy chain for this operation DMX Channel Values CHANNEL VALUE FUNCTION 1 000 004 005 028 029 056 057 084 085 112 113 140 141 168 169 197 198 224 225 255 Color Selection no dimming Blackout Red Green Blue Green Blue Red Blue Red Green Red Green Blue 3 color chase 7 color chase 2 000 004 005 255 Str...

Страница 9: ...y 30 60 days Always dry the parts carefully after cleaning them Never spin a fan using compressed air Power Linking You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines t...

Страница 10: ...ed DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Replace DMX input Faulty Main PCB Replace Main PCB Loss of signal Non DMX cables Use only DMX compatible cables Bouncing signals Install terminator as suggested Long cable Low level signal Install amplifier right aft...

Страница 11: ...r double boxing are recommended CHAUVET reserves the right to use its own discretion to repair or replace product s If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of the shipper therefore the dam...

Страница 12: ...le 155 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 3 ORDERING INFORMATION Trident TRIDENT WARRANTY INFORMATION Warranty 2 year limited warranty Contact Us World Wide General Information CHAUVET 5200 NW 108th...

Отзывы: