6.

 

T

ECHNICAL 

S

PECIFICATIONS

 

 

 

Dimensions and 

Weight 

Length 

Width 

Height  

Weight 

10 in (253 mm) 

3.9 in (98 mm) 

11.4 in (290 mm) 

7.2 lb (3.3 kg) 

 

Note

: Dimensions in inches rounded to the nearest decimal digit. 

 

 

 

 

Power 

Power Supply Type 

Range 

Voltage Selection 

Switching (internal) 

100 to 240 VAC, 50/60 Hz 

Auto-ranging 

 

 

 

Parameter 

120 V, 60 Hz 

230 V, 50 Hz 

Consumption 

82 W 

78 W 

Operating Current 

1 A 

0.6 A 

Power linking current 

(products) 

8 A (7 products) 

8 A (13 products) 

Fuse 

F 2 A, 250 V 

F 2 A, 250 V 

 

 

 

Power I/O 

U.S./Worldwide 

UK/Europe 

Power input connector 

IEC 

IEC 

Power output connector 

Edison 

IEC 

Power Cord plug 

Edison (U.S.) 

Local plug 

 

 

 

 

Light Source

 

Type 

Power 

Lifespan 

LED 

6 W 

50,000 hours 

 

 

 

Color 

Quantity 

Current 

Quad-color RGBA 

12 

2 A 

 

 

 

Photometrics 

Parameter 

Value 

 

Strobe Rate 

0 to 31 Hz 

 

Beam Angle 

16° 

 

Field Angle 

31° 

 

Illuminance @ 2 m 

4,220 lux 

 

Illuminance @ 5 m 

1,015 lux 

 

 

 

 

 

Thermal 

Maximum External Temp. 

Cooling System 

 

104 °F (40 °C) 

Convection 

 

 

 

 

 

DMX 

I/O Connectors 

Channel Range 

 

3-pin XLR 

4, 5 or 10 

 

 

 

 

 

Ordering 

Product Name 

Item Code 

UPC Number 

SlimPAR PRO Q USB 

03031131 

78146221479 

 

 

 

 

 
 
 
 
 

 

Содержание SlimPAR Pro Q USB

Страница 1: ...User Manual...

Страница 2: ...ontrol Panel Operation 9 Menu Map 9 DMX Linking 10 Configuration DMX 10 D Fi USB Connectivity 10 Configuration D Fi USB 10 DMX Personality and Starting Address 11 DMX Channel Assignments and Values 11...

Страница 3: ...peration information Not following these instructions may make the product not work cause damage to the product or cause harm to the operator Important installation or configuration information The pr...

Страница 4: ...outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not exp...

Страница 5: ...erview WARNING DO NOT plug anything other than a D Fi USB into the USB port Doing so may cause damage to the product DMX In Out Power In Microphone D Fi USB Port Power Out Safety Cable Pass Through Fu...

Страница 6: ...Page 6 of 19 SlimPAR PRO Q USB User Manual Rev 3 Product Dimensions 10 in 253 mm 11 4 in 290 mm 3 9 in 98 mm...

Страница 7: ...e rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement 1 Wedge the tip of a flat head screwdriver into the slot of the fuse holder 2 Pry the fuse holder out of the housing 3 Re...

Страница 8: ...curely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When power linking multiple products mount t...

Страница 9: ...ress to activate a menu option or a selected value Menu Map Main Level Programming Levels Description 4 CH d001 512 4 channel DMX mode 5 CH d001 512 5 channel DMX mode 10CH d001 512 10 channel DMX mod...

Страница 10: ...uvet DJ Simply set the product s DMX Personality and DMX Address set the DIP switch D Fi receiving transmitting channel then plug it into the D Fi USB port WARNING DO NOT plug anything other than a D...

Страница 11: ...r DOWN to select the starting address 4 Press ENTER DMX Channel Assignments and Values 10CH Channel Function Value Percent Setting 1 Dimmer 000 255 0 100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Bl...

Страница 12: ...nction Value Percent Setting 1 Dimmer 000 255 0 100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 Amber 000 255 0 100 4 CH Channel Function Value Percent Setting 1 Red 000 255 0 100...

Страница 13: ...active program Snd1 or Snd2 4 Press ENTER The product will only respond to low frequencies of music bass and drums Sound Sensitivity To change the sound sensitivity on the SlimPAR PRO Q USB follow th...

Страница 14: ...ess SENSITIVITY on the IRC 6 2 Press or to increase or decrease the sound sensitivity Manual Color Control To choose a specific color with the IRC 6 1 Press MANUAL on the IRC 6 2 Press any number betw...

Страница 15: ...rom the master Do not connect more than 31 slaves to the master Master Slave Mode D Fi USB The D Fi USB allows a single SlimPAR PRO Q USB product the master to control the actions of one or more SlimP...

Страница 16: ...y To clean the product follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dus...

Страница 17: ...urrent products 8 A 7 products 8 A 13 products Fuse F 2 A 250 V F 2 A 250 V Power I O U S Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison U S...

Страница 18: ...tdj com for contact details Call the corresponding Chauvet Technical Support office and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the mod...

Страница 19: ...ishoutem Belgium Voice 32 9 388 93 97 Email BNLtech chauvetlighting eu Website www chauvetdj eu France Address 3 Rue Amp re 91380 Chilly Mazarin France Voice 33 1 78 85 33 59 Email FRtech chauvetlight...

Отзывы: