General Maintenance 

To maintain optimum performance and minimize wear fixtures should be cleaned frequently.  Usage 

and environment are contributing factors in determining frequency. As a general rule, fixtures should 

be cleaned at least twice a month. Dust build up reduces light output performance and can cause 

overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off 

fixture before conducting maintenance. 

Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust 

collected on external vents and internal components.  Clean all glass when the fixture is cold with a 

mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply 

solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical 

surfaces until they are free of haze and lint.  

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: 
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s 

optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean 

the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.  

Returns Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 

Package must be clearly labeled with a Return Merchandise Authorization Number (R MA #). 

Products returned without an RMA # will be refused. Call CHAUVET and request RMA # prior to 

shipping the fixture. Be prepared to provide the model number, serial number and a brief description 

of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from 
inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own 

discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is 

always a safe method to use. 

Note: 

If you are given an RMA #, please include the following information on a piece of 

paper inside the box: 

1) 

Your name 

2) 

Your address 

3) 

Your phone number 

4) 

The RMA # 

5) 

A brief description of the symptoms 

Claims 

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 

reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and 

submit claims with the shipper in the event that a fixture is damaged due to shipping.  Any other claim 

for items such as missing component/part, damage not related to shipping, and concealed damage, 

must be made within seven (7) days of receiving merchandise. 

Содержание LXW

Страница 1: ... 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com LXW USER MANUAL Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Linking power ...

Страница 2: ...rocedure 9 Claims 9 Technical Specifications 10 1 BEFORE YOU BEGIN What is included 1 x LXW Power Cord Warranty Card User Manual Unpacking Instructions Immediately upon receiving a fixture carefully unpack the carton check the contents to ensure that all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection if any parts...

Страница 3: ...er to a fixture check that the source voltage matches the fixture s requirement Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use Warning Verify that the voltage select switch on your unit matches the line voltage applied Damage to your fixture may result if the line voltage applied does not match th...

Страница 4: ...nt temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Never connect the ...

Страница 5: ...8 4 21 PM Product Overview 1 Sound sensitivity adjustment Hanging bracket Mode selection switch Microphone Safety eyebolt Power link out Voltage selection switch External ground screw Power in fuse holder Bracket adjustment knob ...

Страница 6: ...ded there is adequate room for ventilation RIGGING It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration lamp replacement access and routine main...

Страница 7: ...und active mode Note the light will not turn off It operates with a constant on 1 The unit will react to the low frequencies of music via the internal microphone in Sound Active mode 2 Use the audio sensitivity knob on the back of the unit to make the unit more or less sensitive in Sound Active mode Turning the knob counterclockwise decreases the sensitivity turning the knob clockwise increases th...

Страница 8: ...trol switches If audio provided via jack make sure a live audio signal exists Adjust sound sensitivity knob Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life Moves slow Check 220 110v switch for proper setting No light output Check slip ring brushes for contact Install bulb Call service technician If you still have a problem after trying the abo...

Страница 9: ... fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CHAUVET...

Страница 10: ...tch selectable power settings 115VAC 60Hz or 230VAC 50Hz Power Consumption 11W 0 1A max 120V Inrush Power 0 1A 120V Power Output 80 units max at 120V 160 units max 230V LIGHT SOURCE LED 1x 750mA 1 White 8 500 K 50 000hrs PHOTO OPTIC Beam Angle 39 THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION LXW LXW WARRANTY INFORMATION Warranty 1 year limited warranty ...