background image

 

B

EFORE 

Y

OU 

B

EGIN

 

What is included 

¾

 

1 x LEDrain™38 

¾

 

1 x Power cable (1 m) and 1 x Linking cable (1.5 m) 

¾

 Warranty 

Card 

¾

 Users 

Manual

Unpacking Instructions 

Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

AC Power 

This fixture has an auto-switching power supply that can accommodate a wide range of input 

voltages. The only thing necessary to do before powering on the unit is to make sure the line voltage 

you are applying is within the range of accepted voltages. This fixture will accommodate between 

100V and 240V AC. All fixtures must be powered directly off a switched circuit and cannot be run off a 

rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for 

a 0% to 100% switch.  

Warning! 

All fixtures must be connected to circuits with a suitable Earth Ground. 

 

Safety Instructions 

 

 

Please read these instructions carefully, which includes important 

information about the installation, usage and maintenance? 

 

Please keep this User Guide for future consultation. If you 
sell the unit to another user, be sure that they also receive 
this instruction booklet. 

 

Always make sure that you are connecting to the proper 
voltage and that the line voltage you are connecting to is 
not higher than that stated on decal or rear panel of the 
fixture. 

 

This product is intended for indoor use only! 

 

To prevent risk of fire or shock, do not expose fixture to 
rain or moisture. Make sure there are no flammable 
materials close to the unit while operating. 

 

The unit must be installed in a location with adequate 
ventilation, at least 50cm from adjacent surfaces. Be sure 
that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or 
replacing lamp or fuse and be sure to replace with same 
lamp source. 

 

Secure fixture to fastening device using a safety chain. 
Never carry the fixture solely by its head. Use its carrying 
handles. 

 

Maximum ambient temperature is Ta: 40

°C

. Do not 

operate fixture at temperatures higher than this.  

 

In the event of serious operating problem, stop using the 
unit immediately. Never try to repair the unit by yourself. 
Repairs carried out by unskilled people can lead to 
damage or malfunction. Please contact the nearest 
authorized technical assistance center. Always use the 
same type spare parts. 

 

Don’t connect the device to a dimmer pack. 

 

Make sure power cord is never crimped or damaged. 

 

Never disconnect power cord by pulling or tugging on the 
cord. 

 

Avoid direct eye exposure to lamp while it is on.  

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or attempt any 
repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET.

 

LEDrain™38 User Manual 

3

  

11/28/2007 

10:00 

AM 

Содержание LEDrain 38

Страница 1: ... OK Sound Activated DMX Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2007 11 28 10 08 ...

Страница 2: ...NEL SUMMARY 4 PRODUCT OVERVIEW 5 SETUP 6 POWER 6 MOUNTING 6 OPERATING INSTRUCTIONS 7 MASTER SLAVE MODE 7 Daisy Chain Connection 7 Dipswitch Options 7 DMX CONTROL MODE 8 Setting the DMX address 8 APPENDIX 9 DMX PRIMER 9 Fixture Linking 9 DMX CHANNEL VALUES 10 RETURNS PROCEDURE 11 CLAIMS 11 PHOTOMETRIC 11 DMX DIPSWITCH QUICK REFERENCE CHART 12 TECHNICAL SPECIFICATIONS 13 TECHNICAL SUPPORT 13 ...

Страница 3: ...it to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no fl...

Страница 4: ... mode Static colors and RGB color mixing in master slave mode via dip switches ADDITIONAL FEATURES Additional power output for daisy chaining units together max 50 units Built in automated programs via master slave Built in sound activated programs via master slave Double bracket yoke doubles as floor stand Low power consumption OPTIONS Programmable Any universal DMX 512 controller DMX Channel Sum...

Страница 5: ...nifies the par can is set to be controlled via DMX OFF Par can is set to either Automatic or Sound Active mode as previously selected by the Music Auto switch Hanging yoke also floor stand for uplighting Music Auto switch Power Input Connector Fuse Holder Power Link Out LEDrain 38 User Manual 5 11 28 2007 10 00 AM ...

Страница 6: ...tures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE PIN INTERNATIONAL BROWN Live L BLUE Neutral N YELLOW GREEN Earth EG Ground Mounting Orientation T...

Страница 7: ...to switch to Music and for sound activated triggering of the program Set Music Auto switch to Auto then use the rotary dial to adjust speed of the program See below under Dipswitch Options for additional program settings Daisy Chain Connection 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming fro...

Страница 8: ...ss selected for future reference If this is your first time addressing a fixture using the DMX 512 control protocol than I suggest jumping to the Appendix Section and read the heading DMX Primer It contains very useful information that will help you understand its use Set the start address using the group of DIP switches located usually on bottom of the fixture Each dip switch has an associated va...

Страница 9: ...of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 i...

Страница 10: ... Red Green 100 Blue 60 Red Green 100 Blue 80 Red Green 100 Blue 100 Red Green Blue 100 Red 20 Green Blue 100 Red 40 Green Blue 100 Red 60 Green Blue 100 Red 80 Green Blue 100 Red 100 Green Blue 100 Red 100 Green 25 Blue 100 Red 100 Green 50 Blue 100 Red 100 Green 75 Blue 100 Red 100 Green 100 Blue 100 Red 100 Green 100 Blue 25 Red 100 Green 100 Blue 50 Red 100 Green 100 Blue 75 Red 100 Green 100 B...

Страница 11: ...with a an RA will be refused Call CHA ure Be prepared to provide the model e sure to properly pack fixture an product s As a suggestion prop thod to use Damage incurred refore the damage must be rep pon r the customer s responsibility to notify and sub s damaged due to shipping Any other claim for g co elated to shipping and concealed damage mu dise Photometrics in shipping is the responsibility o...

Страница 12: ...00 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82...

Страница 13: ... 19 34 P ot etric chart See page 11 FUSE Main 20mm Glass 2A Fast Blow C N ROL PROGRAMMING Data input locking 3 pin XLR male socket D D ta ta outpu pin co t nfig urati on l ocking pin 1 3 pin X shield LR fe pin 2 male socket pin 3 Protocols DMX 512 USITT D X Channels 7 O D RING INFORMAT ON L Drain 38 LEDrain 38 Te al Sup ort A 3 d e 0 u h l g dr 00 ss S N 29 erv th C ice D t Ho ept llywood FL 33020...