background image

  

 

 

Appendix 

DMX Control Mode 

Operating in a DMX Control mode environment gives the user the greatest flexibility when it comes to 

customizing or creating a show.  In this mode you will be able to control each individual trait of the 

fixture and each fixture independently. The LEDrain™38 uses 7 channels of control. 

Note: Dipswitch 10 must be turned on to activate DMX control mode.  

Note: Older 8-dipswitch version must have dipswitch 8 turned off to activate DMX control 

mode. Dipswitches 1-7 set the DMX address, and the maximum address is 127. 

S e t t i n g   t h e   D M X   a d d r e s s  

This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start 

address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data 

on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels 

of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 

102, 103, 104, 105 and 106. Choose start addresses so that the channels used do not overlap and 

notate the start address selected for future reference.  

If this is your first time addressing a fixture using the DMX-512 control protocol than I suggest jumping 

to the Appendix Section and read the heading “DMX Primer”. It contains very useful information that 

will help you understand its use.  

Set the start address using the group of DIP switches located usually on bottom of the fixture. Each 

dip switch has an associated value. Adding the value of each switch in the ON position will provide 

the start address. Determining which switches to toggle ON given a specific start address can be 

accomplished in the following manner. By subtracting the largest switch value possible from the 

selected start address until zero is achieved. 

E

XAMPLE 

S

TARTING 

A

DDRESS

 

 

Address 10 

Pin # 4 

= 8 

Pin # 2 

= 2 

Total  

= 10 

 

Address 24 

Pin # 5 

= 16 

Pin # 4 

= 8 

Total = 

24 

 

 

 

Resolving address using  

simple math. 

Address 233

 

233 – (128) = 105, Turn ON Dip # 8 

105 – (64) = 41, Turn ON Dip # 7 

41 – (32) = 9, Turn ON Dip # 6 

9 – (8) = 1, Turn ON Dip # 4 
1 – (1) = 0, Turn ON Dip # 1 

 

You will most likely use the first 

available number which maybe 

number 1. This number was 

selected for example purposes.  

 

D

IP 

S

WITCH

 (DMX

 

V

ALUE








 




16 
32 
64 

128 

 

128 

 

 

16 

32 

64 

ON

 1  2  3  4  5  6  7 8  

 1  2  3  4  5  6  7 8  

ON

128 

 

16 

32 

64 

  

LEDrain™38 User Manual 

 

2007-11-28/10:08 

Содержание LEDrain 38

Страница 1: ... OK Sound Activated DMX Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2007 11 28 10 08 ...

Страница 2: ...NEL SUMMARY 4 PRODUCT OVERVIEW 5 SETUP 6 POWER 6 MOUNTING 6 OPERATING INSTRUCTIONS 7 MASTER SLAVE MODE 7 Daisy Chain Connection 7 Dipswitch Options 7 DMX CONTROL MODE 8 Setting the DMX address 8 APPENDIX 9 DMX PRIMER 9 Fixture Linking 9 DMX CHANNEL VALUES 10 RETURNS PROCEDURE 11 CLAIMS 11 PHOTOMETRIC 11 DMX DIPSWITCH QUICK REFERENCE CHART 12 TECHNICAL SPECIFICATIONS 13 TECHNICAL SUPPORT 13 ...

Страница 3: ...it to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no fl...

Страница 4: ... mode Static colors and RGB color mixing in master slave mode via dip switches ADDITIONAL FEATURES Additional power output for daisy chaining units together max 50 units Built in automated programs via master slave Built in sound activated programs via master slave Double bracket yoke doubles as floor stand Low power consumption OPTIONS Programmable Any universal DMX 512 controller DMX Channel Sum...

Страница 5: ...nifies the par can is set to be controlled via DMX OFF Par can is set to either Automatic or Sound Active mode as previously selected by the Music Auto switch Hanging yoke also floor stand for uplighting Music Auto switch Power Input Connector Fuse Holder Power Link Out LEDrain 38 User Manual 5 11 28 2007 10 00 AM ...

Страница 6: ...tures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE PIN INTERNATIONAL BROWN Live L BLUE Neutral N YELLOW GREEN Earth EG Ground Mounting Orientation T...

Страница 7: ...to switch to Music and for sound activated triggering of the program Set Music Auto switch to Auto then use the rotary dial to adjust speed of the program See below under Dipswitch Options for additional program settings Daisy Chain Connection 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming fro...

Страница 8: ...ss selected for future reference If this is your first time addressing a fixture using the DMX 512 control protocol than I suggest jumping to the Appendix Section and read the heading DMX Primer It contains very useful information that will help you understand its use Set the start address using the group of DIP switches located usually on bottom of the fixture Each dip switch has an associated va...

Страница 9: ...of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 i...

Страница 10: ... Red Green 100 Blue 60 Red Green 100 Blue 80 Red Green 100 Blue 100 Red Green Blue 100 Red 20 Green Blue 100 Red 40 Green Blue 100 Red 60 Green Blue 100 Red 80 Green Blue 100 Red 100 Green Blue 100 Red 100 Green 25 Blue 100 Red 100 Green 50 Blue 100 Red 100 Green 75 Blue 100 Red 100 Green 100 Blue 100 Red 100 Green 100 Blue 25 Red 100 Green 100 Blue 50 Red 100 Green 100 Blue 75 Red 100 Green 100 B...

Страница 11: ...with a an RA will be refused Call CHA ure Be prepared to provide the model e sure to properly pack fixture an product s As a suggestion prop thod to use Damage incurred refore the damage must be rep pon r the customer s responsibility to notify and sub s damaged due to shipping Any other claim for g co elated to shipping and concealed damage mu dise Photometrics in shipping is the responsibility o...

Страница 12: ...00 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82...

Страница 13: ... 19 34 P ot etric chart See page 11 FUSE Main 20mm Glass 2A Fast Blow C N ROL PROGRAMMING Data input locking 3 pin XLR male socket D D ta ta outpu pin co t nfig urati on l ocking pin 1 3 pin X shield LR fe pin 2 male socket pin 3 Protocols DMX 512 USITT D X Channels 7 O D RING INFORMAT ON L Drain 38 LEDrain 38 Te al Sup ort A 3 d e 0 u h l g dr 00 ss S N 29 erv th C ice D t Ho ept llywood FL 33020...

Отзывы: