Introduction
LED-PAR200B User Manual
6
2006-07-06/10:32
Slide switch up or down
depending on your line voltage.
Hanging Clamp
S
ETUP
Power
Your product is equipped with switch-selectable AC power setting.
Warning!
Verify that the power select switch on your unit
matches the line voltage applied. All fixtures must
be connected to circuits with a suitable Earth
Ground.
To determine the power requirements for a particular fixture, see the label affixed to the back plate
of the fixture or refer to the fixture
’
s specifications chart.
A fixture
’
s listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%
to 100% switch.
Before applying power to a fixture, check that the source voltage matches the fixture
’
s
requirement.
All fixtures must be connected to circuits with a suitable Earth Ground.
Po w e r C a b l e C o n f i g u r a t i o n
C
ABLE
P
IN
I
NTERNATIONAL
B
ROWN
Live
L
B
LUE
Neutral
N
Y
ELLOW
/G
REEN
Earth
EG (Ground)
Mounting
O r i e n t a t i o n
This fixture can be mounted on a truss using a clamp in any
position.
R i g g i n g
The fixture includes a mounting yoke to which 1 rigging clamp can be bolted.
1. Align the clamp screw with the center hole on the yoke and tighten.
2. Verify the structure can hold 10 times the weight of all to-be installed fixtures.
3. Adjust the angle on the yoke arm as necessary.