DMX Channel Values 

NOTE! 

Please read all instructions carefully on fixture DMX control mode and addressing.  

DMX channels 2, 3, 4, 5 and 6 functions are determined by the current settings of channel 1. For 

example, while Channel 1 is set between 000 and 029 the following conditions will apply; 

 

Channel 2 will control the Red LEDs 

 

Channel 3 will control the Green LEDs 

 

Channel 4 will control the Blue LEDs 

 

Channel 5 will control Strobing 

 

Channel 6 will control the Dimmer 

 

C

HANNEL

 

V

ALUE

 

F

UNCTION

 

C

C

C

C

C

000 

 029  RGB Control Mode 

Red 

000 

 255 

Green 

000 

 255 

Blue 

000 

 255 

Strobe 

000 

 255 

 

030 

 059 

060 

 119 

Pulse Strobe 
Pulse ( 0 <-> 100% ) 
Pulse ( 100 <-> 0% ) 

No 

Function 

Speed 

000 

 255 

 

120 

 149 

Color Macro 
Color Macros 

See Table 1.1 

No 

Function 

 

150 

 179 

R,G,B Chase 
RGB Chase pattern 

 

180 

 209 

Automatic  
Color Change 

 

210 

 239 

Automatic (Fade) 
Color Change w fade 

Speed 

000 

 255 

 

240 

 255 

 

Sound Activated 
Music/Auto switch 
must be set to Music 

 

No 

Function 

No 

Function 

No 

Function 

No 

Function 

Dimmer 

000 

 255 

 

 

Table 1.1 

M

ODE

 

C

D

ESCRIPTION

 

000 

 016  Red 

017 

 056 

 

Red ( Full ) 
Green: ( 0% ~ 100% ) 

057 

 094 

 

Green (Full 
Red: ( 100% ~ 0% ) 

095 

 096  Green 

097 

 136 

 

Green ( Full ) 
Blue: ( 0% ~ 100% ) 

137 

 174 

 

Blue ( Full ) 
Green: ( 100% ~ 0% ) 

175 

 176  Blue 

177 

 216 

 

Blue ( Full ) 
Red: ( 0% ~ 100% ) 

Color 

Macro 

 

Ch 1 

120 

 149 

217 

 255 

 
 

Blue ( Full ) 
Red ( Full ) 
Green: ( 0% ~ 100% ) 

 

Music/Auto Switch 

Note!  Regardless of DMX controller 
operated use, when the LED-
PAR200B is set to run in Sound 
Activated mode, you should make 
sure that all units are properly 
switched to Music and that you have 
adjusted the rotary dial to optimize the 
sound level response of the unit.  

S

WITCH

 

R

OTARY  

F

UNCTION

 

A

UTO

 

Adjusts speed of built in 
program 

M

USIC

 

Adjusts sound sensitivity of 
built in Mic. 

 

Содержание LED-PAR200B

Страница 1: ...CHAUVET 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 07 06 10 32 LED PAR200B COLORsplash 200B USER MANUAL ...

Страница 2: ... DMX CHANNEL SUMMARY 4 PRODUCT OVERVIEW 5 SETUP 6 POWER 6 MOUNTING 6 OPERATING INSTRUCTIONS 7 MASTER SLAVE MODE 7 Daisy Chain Connection 7 Dipswitch Options 7 DMX CONTROL MODE 8 Setting the DMX address 8 APPENDIX 9 DMX PRIMER 9 Fixture Linking 9 DMX CHANNEL VALUES 10 RETURNS PROCEDURE 11 CLAIMS 11 PHOTOMETRIC 11 DMX DIPSWITCH QUICK REFERENCE CHART 12 TECHNICAL SPECIFICATIONS 13 TECHNICAL SUPPORT 1...

Страница 3: ...this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not ex...

Страница 4: ...Dimmer 000 255 DMX CHANNEL COLUMNS CONTROL MODES OPTIONS Rows For a detailed view of DMX values turn to the Appendix section in this manual Control mode parameters are set by DMX values in Channel 1 INTRODUCTION Features CONTROL FEATURES 6 channel DMX 512 LED washlight can 199 ultra bright LEDs 67 red 66 green 66 blue Built in color change programs FEATURES Ultra bright LED s RGB color mixing Up t...

Страница 5: ...oltage Fuse Blue LED Status Blinks continuously DMX signal present Solid Music mode LED will blink in Auto mode to signify rate or speed set by the Min Max rotary button Hanging yoke All LEDs evenly staggered for optimum color generation Red LED Power Indicator Min Max Rotary button Music Auto switch Product Overview ...

Страница 6: ...owered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requirement All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE PIN INTERNATI...

Страница 7: ... Music and for sound activated triggering of the program Set Music Auto switch to Auto then use the rotary dial to adjust speed of the program See below under Dipswitch Options for additional program settings Daisy Chain Connection 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first ...

Страница 8: ...your first time addressing a fixture using the DMX 512 control protocol than I suggest jumping to the Appendix Section and read the heading DMX Primer It contains very useful information that will help you understand its use Set the start address using the group of DIP switches located usually on bottom of the fixture Each dip switch has an associated value Adding the value of each switch in the O...

Страница 9: ... OUT of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin ...

Страница 10: ...s See Table 1 1 No Function 150 179 R G B Chase RGB Chase pattern 180 209 Automatic Color Change 210 239 Automatic Fade Color Change w fade Speed 000 255 1 240 255 Sound Activated Music Auto switch must be set to Music No Function No Function No Function No Function Dimmer 000 255 Table 1 1 MODE CH 2 DESCRIPTION 000 016 Red 017 056 Red Full Green 0 100 057 094 Green Full Red 100 0 095 096 Green 09...

Страница 11: ...tomer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit ...

Страница 12: ... 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 1...

Страница 13: ... Blue 66 Beam Angle 45 Illuminance 86 4fc or 930lux 1 meter FUSE Main 20mm Glass 2A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 6 ORDERING INFORMATION COLORsplash 200B LED PAR200B Technical Support Address Service Dept 3000 N 29th Ct Hollywood ...