background image

 
 

 
Scorpion™ GBC User Manual 

23 

August 2011 

Product Linking 

You will need a serial data link to run light shows of one or more products using a DMX controller or 
to run synchronized shows on two or more products set to a master/slave operating mode. The 
combined number of channels required by all the products on a serial data link determines the 
number of products the data link can support.  

Products on a serial data link must be daisy chained in one single line. To comply with the 
EIA-485 standard, no more than 32 products should be connected on one data link. 
Connecting more than 32 products on one serial data link without the use of a DMX 
optically-isolated splitter may result in deterioration of the digital DMX signal.  

 

Maximum recommended serial data link distance: 500 m (1640 ft)  

 

Maximum recommended number of products on a serial data link: 32 

 

Setting the Starting Address 

This DMX mode enables the use of a universal DMX controller device. Each product requires a 
start address from 1~512. A product requiring one or more channels for control begins to read the 
data on the channel indicated by the start address. For example, a product that uses six DMX 
channels and was addressed to start on DMX channel 100, would read data from channels: 100, 
101, 102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap, 
and note the start address selected for future reference. 

If this is your first time addressing a product using the DMX control protocol, we suggest jumping to 
the “Appendix” section and reading the heading “DMX Primer”. It contains very useful information 
that will help you understand its use. 

 

Содержание Laser Pointer

Страница 1: ...LASER LIGHT AVOID DIRECT EYE EXPOSURE CLASS IIIa LASER PRODUCT CLASSIFIED PER 21 CFR 1040 10 11 Complies with US FDA CDRH laser safety standards 21 CFR 1040 10 1040 11 User Manual ...

Страница 2: ...upport Email uktech chauvetlighting com World Wide Web World Wide Web www chauvetlighting com www chauvetlighting co uk Document Information The information and specifications contained in this document are subject to change without notice CHAUVET assumes no responsibility or liability for any errors or omissions that may appear in this manual Copyright 2011 CHAUVET All rights reserved Printed in ...

Страница 3: ... 11 Fuse Replacement 12 Mounting 12 Orientation 12 Rigging 12 Proper Usage 13 4 Operation 14 Control Panel 14 DMX Operation 14 DMX Channel Summary 15 Standalone Operation 15 Automatic 15 Sound Active 15 Laser Sky 15 Master Slave Operation 16 Menu Functions 16 DMX Channel Values 17 Channel 2 Values Pattern Selection 18 5 Technical Information 19 General Troubleshooting 19 Returns Procedure 20 Conta...

Страница 4: ...mage not related to shipping or concealed damage you should make claims to CHAUVET within seven 7 days of receiving the merchandise Text Conventions Convention Meaning Menu A key to be pressed on the product s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status Me...

Страница 5: ...the unit Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Never connect this product to a dimmer pack Make sure the power cord is not crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Never carry a product from the power cord or any moving part Always use the hanging mounti...

Страница 6: ...is aimed below people s faces such as on a dance floor Do not operate the laser without first reading and understanding all safety and technical data in this manual Always set up and install all laser effects so that all laser light is at least 3 meters 9 8 feet above the floor on which people can stand See the Proper Usage section later in this manual After set up and prior to public use test the...

Страница 7: ...2011 Laser Safety Labels Reproduction LASER HAZARD WARNING LABEL LASER APERTURE LABEL EXPLANATORY MANUFACTURER S ID CERTIFICATION LABEL NON INTERLOCKED HOUSING LABEL CAUTION CLASS 3B LASER RADIATION WHEN OPEN AVOID EXPOSURE TO THE BEAM ...

Страница 8: ...GBC Laser Classification Class IIIa equiv to US Class IIIa Green Laser Medium DPSS Nd YVO4 532 nm Blue Laser Medium 473 nm typical Beam Diameter 5 mm at aperture Pulse Data All pulses 4 Hz 0 25 sec Divergence each beam 2 mrad Divergence total light 160 degrees Laser Power of Each Beam from Aperture 5 mW As measured under IEC measurement conditions for classification Laser Compliance Statement This...

Страница 9: ...RODUCTION Product Overview Power LED Hanging bracket Bracket adjustment knob 1 of 2 Audio LED Laser Aperture Microphone Control Panel Power on off Microphone Sensitivity Safety Attachment Fuseholder Power In Power Out DMX Out DMX In Back Panel Vi ...

Страница 10: ...Scorpion GBC User Manual 10 August 2011 Product Dimensions ...

Страница 11: ...duct s specifications chart A product s listed current rating indicates its average current draw under normal conditions Always connect the product to a circuit with a suitable electrical ground Power Linking This product contains power linking via the Edison outlet located in front of the power input cable Please see the diagram below for further explanation The maximum number of products that ma...

Страница 12: ...duct may be mounted in any safe position provided there is adequate room for ventilation Rigging It is important never to obstruct the fan or vents pathway Mount the product using a suitable C or O type clamp Adjust the angle of the product by loosening both knobs and tilting the product After finding the desired position retighten both knobs When selecting installation location take into consider...

Страница 13: ...unting hardware from your lighting vendor International laser safety regulations require that laser products must be operated in the fashion illustrated below with a minimum of 3 meters 9 8 ft of vertical separation between the floor and the lowest laser light vertically Additionally 3 meters of horizontal separation is required between laser light and audience or other public spaces CAUTION USE O...

Страница 14: ... operating mode which will allow for control with an external DMX controller You must set the starting address for this mode If this is your first time using DMX then it is recommended that you refer to the DMX Primer section in the Appendix of this manual When operating in DMX receiving mode the display will blink at a constant rate in the absence of DMX signal Use the following procedure for set...

Страница 15: ... preprogrammed sound triggered programs These are accessed via the LED display on the back panel of the product The sound control adjustment knob may be used to adjust the microphone sensitivity Please see the instructions below for further explanation 1 Press MODE until a standalone mode appears on the LED display See the chart under menu functions to identify these 2 Use UP and DOWN to scroll th...

Страница 16: ...hat is operating in one of the standalone modes will function as a master unit when the products are linked using DMX cables in a daisy chain configuration Menu Functions MAIN FUNCTION SELECTION DESCRIPTION VALUES DMX mode 001 001 511 DMX starting address assignment Standalone modes AFB Automatic fast blue ASB Automatic slow blue AFG Automatic fast green ASG Automatic slow green AFC Automatic fast...

Страница 17: ...25 255 Color selection Blackout Preprogrammed Color Blue Green Cyan Alternate Blue Green Alternate Green Cyan Alternate Blue Cyan Alternate Blue Green Cyan Color Roll 4 000 004 005 255 Color Changing Speed Stop Slow fast 5 000 127 128 169 170 209 210 255 Zoom 100 5 Zoom In Macro Zoom Out Macro Zoom In and Out Macro 6 000 127 128 191 192 255 X Axis Move Pan 128 different positions on Y Axis Move Le...

Страница 18: ...ue Pattern Value Pattern Value Pattern 000 007 064 071 128 135 190 197 008 015 072 079 136 143 198 205 016 023 080 087 144 151 206 213 024 031 088 095 152 159 214 221 032 039 096 103 160 167 222 229 040 047 104 111 168 175 230 237 048 055 112 119 176 181 238 245 056 063 120 127 182 189 246 255 ...

Страница 19: ...too slow Check user manual for speed adjustment Device has no power Check for power on Mains Check device s fuse internal and or external Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights No laser output Bounce mirror motor may have shifted during shipping readjust If you still have a problem after trying the above solutions plea...

Страница 20: ...inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA please include the following information on a piece of paper inside the box Your name Your address Your phone number The RMA A brief description of th...

Страница 21: ...on is where the DATA OUT of one product connects to the DATA IN of the next product The order in which the products are connected is not important and has no effect on how a controller communicates to each product Use an order that provides for the easiest and most direct cabling Connect products using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shiel...

Страница 22: ...m capacitance between conductors 30 pF ft Maximum capacitance between conductor and shield 55 pF ft Maximum resistance 20 ohms 1000 ft Nominal impedance 100 140 ohms Cable Connectors Cabling must have a male XLR connector on one end and a female XLR connector on the other end Do not allow contact between the common and the product s chassis ground Grounding the common can cause a ground loop and y...

Страница 23: ...al DMX signal Maximum recommended serial data link distance 500 m 1640 ft Maximum recommended number of products on a serial data link 32 Setting the Starting Address This DMX mode enables the use of a universal DMX controller device Each product requires a start address from 1 512 A product requiring one or more channels for control begins to read the data on the channel indicated by the start ad...

Страница 24: ...ax Inrush Current 230 V 0 2 A Power Output 20 units max LASER Green diode 532 nm 30 mW Blue diode 473 nm 40 mW Laser Type DPSS Cooling Fan Cooled RANGE Coverage Angle 47 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Ch...

Отзывы: