Operation
STRIKE™ 324 User Manual Rev. 3
-9-
4. Operation
Control Panel
Description
Button
Function
<MENU>
Exits from the current menu or function
<ENTER>
Enables the currently displayed menu or sets the currently
selected value in to the current function
<UP>
Navigates upward through the menu list and increases the
numeric value when in a function
<DOWN>
Navigates downward through the menu list and decreases the
numeric value when in a function
Control Options
You can set the STRIKE™ 324 starting address in the 001–512 DMX range. This
enables control of up to 42 products in the 12-channel
12 Ch
personality.
Programming
Refer to the
Menu Map
to understand the menu options. The menu map shows the main
level and a variable number of programming levels for each option.
•
To go to the desired main level, press
<MENU>
repeatedly until the option shows on
the display. Press
<ENTER>
to select. This will take you to the first programming
level for that option.
•
To select an option or value within the current programming level, press
<UP>
or
<DOWN>
until the option shows on the display. Press
<ENTER>
to select. In this
case, if there is another programming level, you will see that first option, or you will
see the selected value.
•
Press
<MENU>
repeatedly to exit to the previous main level.
DMX Personality
This setting allows you to choose a particular DMX personality.
1. Go to the
Channel
main level.
2. Select the desired personality (
1 Ch
,
5 Ch
,
8 Ch
, or
12 Ch
).
•
See the DMX Values section for the highest starting address you can select for each
personality.
•
Make sure that the starting addresses on the various products do not overlap due to
the new personality setting.
DMX Control
In this mode, each product will respond to a unique starting address from the DMX
controller. All products with the same starting address will respond in unison.
1. Select a DMX personality as shown in
DMX Personality
.
2. Set the running mode:
a. Go to the
M&S Mode
main level.
b. Select
Slave
.
3. Set the starting address:
a. Go to the
Address
main level.
b. Select the starting address (
001–512
).
The highest recommended starting address for each DMX mode is as follows:
DMX Mode
DMX Address
1 Ch
512
5 Ch
508
8 Ch
505
12 Ch
501