GigBAR™ IRC User Manual Rev. 2
Page 15 of 96
3.
S
ETUP
AC Power
The GigBAR™ IRC has an internal auto-ranging power supply and it can work with an input
voltage range of 100 to 240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use
the current value listed on the label affixed to the product’s back panel, or refer to
Technical
Specifications
in this manual. The listed current rating indicates the product’s average current
draw under normal conditions.
Always connect the product to a protected circuit (circuit breaker or fuse). Make sure the
product has an appropriate electrical ground to avoid the risk of electrocution or fire.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
Fuse
Replacement
Disconnect the product from power.
1.
Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
2.
Pry the fuse holder out of the housing.
3.
Remove the blown fuse from the holder.
4.
Replace with a fuse of the exact same type and rating.
5.
Insert the fuse holder back in place and reconnect power.
6.
Disconnect the product from power before replacing the fuse.
The product does not ship with a spare fuse; however, the safety cap has room for a spare.
Always replace a blown fuse with a fuse of the same type and rating.
Interlock
Connector
This product has a jack for a remote interlock switch that would shut off the laser output in case
of emergency. You may use the provided remote interlock connector to build your own interlock
switch.
Power Linking
Power linking is when products are daisy chained together through the power in and power out
plugs, allowing many products to be powered from one wall outlet.
Up to 29 GigBAR™ IRC products can be power linked at 230 V.
Do not power link more than 29 GigBAR™ IRC on 230 V.
Installed fuse
(held by plastic clip)
Spare fuse holder
(inside safety cap)
Safety cap