The Kinta (DMX-311X) is a single channel DMX fixture. Please consult the 

controller

manual to 

determine the proper address for the Kinta (DMX-311X).  Addressing your DMX-311X is 
simple, just remember that each dip switch is equal to twice the value of the previous one.

For example:

So, If you wanted to set your Kinta to channel 12, you would set SW #4 (value of 8) and SW#3 (value of

4) into the on position like this.  (8 + 4 = 12)

DMX Signal Levels

Installation / Mounting

T

his unit has been designed to be properly mounted using a suitable hanging clamp and safety cable.

C H A U V E T offers a range of items, which are ideal for safe mounting.

Mount the Kinta in a well-ventilated area without obstruction to the fan or vents to prevent damage from 

overheating.

DMX512 Control Value Rotating Direction Speed (Step per second)

0

Counterclockwise

0 step/sec

2-24

Counterclockwise

60 stp/sec

25-50

Counterclockwise

40 stp/sec

51-76

Counterclockwise

24 stp/sec

77-102

Counterclockwise

15 stp/sec

103-127

Counterclockwise

8  stp/sec (stutter)

128

0 stp/sec

129-153

Clockwise

8 stp/sec (stutter)

154-179

Clockwise

15 stp/sec

180-205

Clockwise

24 stp/sec

206-231

Clockwise

40 stp/sec

232-250

Clockwise

60 stp/sec

255

Stand Alone

Dip Switch Number

1 2 3 4

5

6

7

8

9

10

Place Value

1 2 4 8 16 32 64 128 256 512

1

2

3

4

5

6

7

8

9

10

Off

On

Value

1

2

4

8

16

32

64

128

256

Содержание DMX-311X

Страница 1: ...rld wide Headquarters 3000 North 29th Ct Hollywood FL USA 33020 Tel 1 954 929 1115 Fax 1 954 929 5560 www ChauvetLighting com KINTA DMX 311X User Guide Please read these instructions carefully before use ...

Страница 2: ...with a suitable power plug The unit is equipped with a switchable power supply located on the right hand side of the unit check the voltage selector switch and verify it is set correctly for your local voltage The Kinta DMX 311X is a one channel DMX fixture that can be blacked out with the complimentary CH X controller or programmed with Chauvet s DMX 6 DMX 40 DMX 50 ShowXpress Plus X Factor or an...

Страница 3: ...AUVET o ffers a range of items which are ideal for safe mounting Mount the Kinta in a well ventilated area without obstruction to the fan or vents to prevent damage from overheating DMX512 Control Value Rotating Direction Speed Step per second 0 Counterclockwise 0 step sec 2 24 Counterclockwise 60 stp sec 25 50 Counterclockwise 40 stp sec 51 76 Counterclockwise 24 stp sec 77 102 Counterclockwise 1...

Страница 4: ... fuse holder cover to reveal the fuse 3 Remove the old fuse 4 Place new fuse inside the holder Notes on fuses see below 5 Screw the fuse holder cover back on Notes on fuses This unit has a label attached which indicates the correct fuse rating If needed you can also find this listed as part of the specifications for the unit later in this guide It is critical that replacement fuses are of the corr...

Отзывы: