background image

Setup 

 
 

COLORado™ 1 Tour User Manual Rev. 01f 

-8- 

February 16, 2010 

Mounting 

 

Before mounting this fixture, read and apply the safety recommendations indicated in 
the 

Safety Notes 

of this manual. 

   

 

Orientation 

 

Always mount this fixture in any safe position while making sure that there is adequate 
room around it for ventilation. 

Make sure to mount this fixture away from any flammable material as indicated in the 

Safety Notes

   

 

Rigging 

 

The COLORado™ 1 Tour consists of a sealed housing with a double bracket mounting 
yoke. It has two DMX signal sockets (DMX In/out), and two NEUTRIK®  powerCON 
connectors (Power In/Out).  

CHAUVET®  recommends following  the general guidelines  below  when mounting  the 
COLORado™ 1 Tour. 

   

 

   

 

When selecting an installation location, consider ease of access to the fixture for 
operation, programming adjustments and routine maintenance.  

 

Never mount the fixture in places where rain, high humidity, extreme temperature 
changes or restricted ventilation may affect it. 

 

Make sure that the location where you are mounting the fixture can support its 
weight. Please see the 

Technical Specifications

 section of this manual for the 

weight requirement of this fixture. 

   

 

Procedure 

 

This fixture includes a mounting yoke to which you can attach one or two rigging 
clamps. You must supply your own “C” or “O” clamps and make sure that they are 
capable of supporting the weight of this fixture. CHAUVET® recommends using at least 
two mounting points per fixture. 

   

 

Product 

Mounting 

Diagram 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

Floor Mounting

 

 
 
 
 
 
 
 
 

Overhead Mounting

 

 

   

 

 
 

Secure the safety cable 
using the passageway on 
the back of the fixture. 

Содержание COLORado 1 Tour

Страница 1: ...User Manual ...

Страница 2: ...A4 paper 210 x 297 mm configure your printer to scale the content of this document to A4 paper Intended Audience Any person in charge of installing operating and or maintaining the COLORado 1 Tour should read the Quick Start Guide that shipped with the COLORado 1 Tour fixture and this manual in their entirety before installing operating or maintaining the COLORado 1 Tour Disclaimer CHAUVET believe...

Страница 3: ...Linking 6 DMX Connection 6 Master Slave Linking 7 ID Addressing 7 Lens Replacement 7 Mounting 8 Orientation 8 Rigging 8 4 Operation 9 Control Panel Description 9 Control Options 9 Programming 9 DMX Personality 9 DMX Control Without ID Addressing 9 DMX Control With ID Addressing 10 Static Color 10 Auto Programs 10 Edit Customs 10 Master Slave 10 Color Adjustment 11 Dimmer Curves 11 Control Panel Lo...

Страница 4: ...DMX Configuration 24 Personalities 24 Starting Address 24 Assigning Addresses 25 DMX Universes 25 DMX Connectivity 25 Fixture Location 25 Number of Fixtures 25 DMX Data Cabling 25 Making your Own DMX Cable 25 DMX Cable Characteristics 25 DMX Cable Connectors 26 3 Pin to 5 Pin Conversion Chart 26 DMX Connection 26 Master Slave Linking 27 Master Slave Connection 27 ID Addressing 28 Single Row Connec...

Страница 5: ...ion Meaning 1 512 A range of values 50 60 A set of mutually exclusive values in the text 10 A DIP switch to be configured Claims A fixture function a new term a section or a chapter COLORado UM The name of another publication or manual SET A button to be pressed on the fixture s control panel Settings A menu option that can be selected but not modified MENU Settings A sequence of menu options to b...

Страница 6: ...shock do not expose this product to rain or moisture Make sure there are no flammable materials close to the fixture s while operating When hanging this fixture always secure it to a fastening device using a safety cable included Power and Wiring Always make sure that you are connecting the COLORado 1 Tour to the proper voltage as per the specifications in this manual or on the product s sticker N...

Страница 7: ...addressing Operating modes personalities 3 channel RGB control 3 channel HSV control hue saturation and value 4 channel RGBW control 4 channel RGB dimmer 5 channel RGBW dimmer 6 channel RGBW dimmer strobe 11 channel RGBW ID dimmer strobe macro auto custom dimmer speed auto speed RGBW color mixing with or without DMX controller Color temperature presets 3 200 10 000 K Built in automated programs vi...

Страница 8: ...ed Adjust 10 Dimmer Speed 11 ID Address ARC1 DMX Channel Function 1 Red 2 Green 3 Blue AR1 D DMX Channel Function 1 Master Dimmer 2 Red 3 Green 4 Blue ARC2 DMX Channel Function 1 Red 2 Green 3 Blue 4 White AR2 D DMX Channel Function 1 Master Dimmer 2 Red 3 Green 4 Blue 5 White AR2 S DMX Channel Function 1 Master Dimmer 2 Red 3 Green 4 Blue 5 White 6 Strobe HSV DMX Channel Function 1 Hue 2 Saturati...

Страница 9: ...Introduction February 16 2010 5 COLORado 1 Tour User Manual Rev 01f Product Overview DMX In DMX Out Power Out Power In Safety cable passageway Control Panel A 13 mm B 30 mm ...

Страница 10: ...or on one end an Edison plug on the other end US market If the power cord that came with your fixture has no plug or you need to change the Edison plug use the table below to wire the new plug Connection Wire US Wire Europe Screw Color AC Live Black Brown Yellow or Brass AC Neutral White Blue Silver AC Ground Green Yellow Green Yellow Green Fuse Replacement The COLORado 1 Tour fixture has no exter...

Страница 11: ...iliar with ID Addressing please refer to Appendix chapter of this manual Lens Replacement The COLORado 1 Tour comes with the 15 lens assembly pre installed from the factory However there is an optional lens kit CLENS3042 available as an accessory which will alter the beam angle of the fixture to 30º a Disconnect the fixture from the AC power before opening it b This procedure gives you direct acce...

Страница 12: ...ado 1 Tour When selecting an installation location consider ease of access to the fixture for operation programming adjustments and routine maintenance Never mount the fixture in places where rain high humidity extreme temperature changes or restricted ventilation may affect it Make sure that the location where you are mounting the fixture can support its weight Please see the Technical Specificat...

Страница 13: ...all the programming procedures indicated below from the control panel Refer to the Menu Map to learn how the menu options relate to each other When navigating the menu map remember that MENU will take you to the left of the menu map while ENTER will take you to the right Similarly UP and DOWN will displace the menu options up or down similar to Page UP and Page Down in a computer keyboard Do not f...

Страница 14: ...Go to AUTO 2 Select the desired auto program AT 01 10 or PR 01 10 You cannot edit auto programs AT 01 10 However you can edit PR 01 10 see Edit Customs Edit Customs This setting allows for the programming of up to 30 scenes for each of the 10 customizable programs including colors and effects 1 Go to EDIT 2 Select the desired auto program PR 01 10 3 Select the desired scene SC 01 30 4 Select the d...

Страница 15: ...rol Panel Lock This setting allows the user to activate or disable the control panel lock which keeps non authorized personnel from changing the fixture s settings 1 Go to KEY 2 Select On Off When the control panel lock is active the fixture will prompt the user to enter the password after 30 seconds of control panel inactivity or after turning on the fixture After being prompted to enter the pass...

Страница 16: ...1 white colors used in the Macros channel The 11 pre set whites are configurable 1 Go to CAL1 2 Select a white color WT 1 11 3 Select a color Red Green Blue or White 4 Select a color value 0 255 5 Repeat for the other colors Red Green Blue or White 6 Repeat for the other white colors WT 1 11 White Calibration This setting allows the user to select the white color shown by the COLORado 1 Tour when ...

Страница 17: ...ro Channel 6 has priority over channels 2 3 4 and 5 Channel 1 controls the intensity of the Color Macro Strobe Channel 7 controls the strobe of channels 2 6 ID Address Selection Channel 11 selects the target ID address Each independent DMX address may have up to 66 independent ID addresses An ID address of 0 will activate all ID address locations Auto Channel 8 selects the preset Auto programs AT ...

Страница 18: ...Operation COLORado 1 Tour User Manual Rev 01f 14 February 16 2010 COLORado 1 Tour Menu Map ...

Страница 19: ...d 100 Green 100 Blue 100 White 100 White 1 3 200 K White 2 3 400 K White 3 4 200 K White 4 4 900 K White 5 5 600 K White 6 5 900 K White 7 6 500 K White 8 7 200 K White 9 8 000 K White 10 8 500 K White 11 10 000 K 7 Strobe 000 ó 010 011 ó 255 No function 0 20 Hz 8 Auto 000 ó 020 021 ó 030 031 ó 040 041 ó 050 051 ó 060 061 ó 070 071 ó 080 081 ó 090 091 ó 100 101 ó 110 111 ó 120 121 ó 130 131 ó 140 ...

Страница 20: ...ID 32 ID 33 ID 34 ID 35 ID 36 ID 37 ID 38 ID 39 ID 40 ID 41 ID 42 ID 43 ID 44 ID 45 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 ID 46 ID 47 ID 48 ID 49 ID 50 ID 51 ID 52 ID 53 ID 54 ID 55 ID 56 ID 57 ID 58 ID 59 ID 60 ID 61 ID 62 ID 63 ID 64 ID 65 ID 66 ARC1 Channel Function Value Percent Setting 1 Red 000 ó 255 0 100 2 Green 000 ó 255 0 100 3 Blue 000 ó 255...

Страница 21: ...0 100 6 Strobe 000 ó 010 011 ó 255 No function 0 20 Hz HSV Channel Function Value Percent Setting 1 Hue 000 ó 255 0 100 2 Saturation 000 ó 255 0 100 3 Value 000 ó 255 0 100 In HSV mode Hue refers to the visible light such as red yellow and cyan etc Saturation is the dominance of hue in the color when saturation is at 100 the color is at its purest Value is the color s brightness when value is at 1...

Страница 22: ...recommendations Unplug the fixture from power Wait until the fixture is cold Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents and reachable internal components Clean all external optics and glass surfaces with a mild solution of glass cleaner or isopropyl alcohol and a soft lint free cotton cloth or a lens cleaning tissue Apply the solution directl...

Страница 23: ...wires Check for a short in the electrical wiring Fixture does not power up No power Check for power on power outlet Loose or damaged power cord Check power cord Blown internal fuse Replace internal fuse Faulty internal power supply Replace internal power supply Fixture does not respond to DMX Wrong DMX addressing Check Control Panel and unit addressing Damaged DMX cables Check DMX cables Wrong pol...

Страница 24: ...ower supply P142 C1T 9 Driver board P172 C1T 10 Power connection board P136 C1TPCB 11 Display Main board P173 C1T 12 Button Module P170 C1DSBUT 13 Display protection plate P150 C1GLSM 14 Button seal P170 C1BUTS 15 Casing P300 C1TM 16 Adjusting stainless steel knob P111 C1MKNOB 17 NEUTRIK PowerCON B connector P136 NAC3FCB 18 NEUTRIK PowerCON A connector P136 NAC3MPA 19 3 pin DMX In socket P135 DMXI...

Страница 25: ...Technical Information February 16 2010 21 COLORado 1 Tour User Manual Rev 01f Photometrics ...

Страница 26: ... resulting from inadequate packaging will be the customer s responsibility As a suggestion proper UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace returned product s Claims The shipper is responsible for any damage incurred during shipping Therefore if the received merchandise appears damaged due to shipping the c...

Страница 27: ... W 50 000 hrs LEDs Configuration 42 units Red 12 units 350 mA Green 12 units 350 mA Blue 12 units 350 mA White 6 units 350 mA Photo Optic Luminance 2 m with included 15 degree lenses 3 920 lux Beam Angle with included 15 degree lenses 13 Field Angle with included 15 degree lenses 27 Thermal Cooling Natural convection Maximum ambient temperature 104 F 40 C Control Programming Data input Locking 3 p...

Страница 28: ...y value in the 000 255 range Each DMX compatible fixture uses as many consecutive DMX channels as features the user can control The sequential numbers assigned to each DMX channel 1 512 are also known as DMX addresses The function each DMX channel has and the results of assigning a value to each depend on each controlled fixture Some fixtures only use a single DMX channel while others may require ...

Страница 29: ... controller communicates to each fixture However the user should always define a physical location for the fixtures that provides for the easiest and most direct cabling to the controller and other fixtures Number of Fixtures When using a DMX controller the combined number of channels required by all the fixtures on the serial data link determines the number of fixtures the DMX controller has to s...

Страница 30: ...ative signal Pin 2 Pin 2 Positive signal Pin 3 Pin 3 Not Used Pin 4 Not Used Pin 5 DMX Connection Make sure that the fixtures with which you are working can operate in DMX mode not in a proprietary connection mode Refer to the fixtures manual to learn how to enable their respective DMX modes The procedure below illustrates a possible DMX connection method 1 Connect the 3 pin male connector of the ...

Страница 31: ...MX controller involved Refer to the fixtures manual to learn how to configure them to work in Master Slave mode The procedure below illustrates a possible connection method 1 Connect the 3 pin male connector of the first DMX cable to the DMX Output connector 3 pin female of the master fixture 2 Connect the 3 pin female connector of the first DMX cable coming from the master fixture to the DMX Inpu...

Страница 32: ...multaneously the whole group of units at that DMX address by setting the ID Addressing channel to 0 Similarly the user can control each fixture at that DMX address independently by first selecting the DMX address and then using the ID Addressing channel to locate the target ID address Single Row ID Addressing Diagram Standard Block Connection In the Standard Block connection the fixtures appear in...

Страница 33: ... fact as the PF decreases the difference between the current calculated using the watts volts method and the actual current increases Therefore for fixtures with a PF below 0 9 the installer must always consider the fixture s PF when using the watts figure to calculate the current it draws For the above example if the published fixture s PF were 0 7 the resulting drawn current would be as follows ...

Страница 34: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com COLORado 1 Tour User Manual Rev 01f February 2010 ...

Отзывы: