NON-INTERLOCKED HOUSING WARNING 

This unit contains high power laser devices internally. Do not open the laser housing, due to potential exposure to unsafe 
levels of laser radiation. The laser power levels accessible, if the unit is opened, can cause instant blindness, skin burns 
and fires. 

 

LASER SAFETY AND OPERATING INSTRUCTIONS 

 

 
 
 
 
Laser Light is different from any other light sources with which you may be familiar. The light from this product can 
potentially cause eye injury if not set up and used properly. Laser light is thousands of times more concentrated than light 
from any other kind of light source. This concentration of light can cause instant eye injuries, primarily by burning the 
retina (the light sensitive portion at the back of the eye). Even if you cannot feel “heat” from a laser beam, it can still 
potentially injure or blind you or your audience. Even very small amounts of laser light are potentially hazardous even at 
long distances. Laser eye injuries can happen quicker than you can blink. 
 
It is incorrect to think that because this laser entertainment product changes the laser into a refracted diffuse beam, that 
an individual laser beam is safe for eye exposure. This laser product uses dozens of milliwatts of laser power (Class 3B 
levels internally) before it changes the laser into a refracted diffuse beam (Class 3R levels). All areas of output are 
potentially hazardous to the eyes. 
 
It is also incorrect to assume that because the laser light is moving, it is safe. This is not true. Nor, does the laser always 
move. Since eye injuries can occur instantly, it is critical to prevent the possibility of any direct eye exposure. In the laser 
safety regulation, it is not legal to aim Class 3R lasers in areas which people can get exposed. This is true even if it is 
aimed below people’s faces, such as on a dance floor. 

 

 

Do not operate the laser without first reading and understanding all safety and technical data in this  
manual. 

 

Always set up and install all laser effects so that all laser light is at least 3 meters (9.8 feet) above the floor on 
which people can stand. See “Proper Usage” section later in this manual. 

 

After set up, and prior to public use, test laser to ensure proper function. Do not use if any defect is detected. 
Do not use if laser emits only partial output or a concentrated output (single beam), as this could indicate 
damage to the optics, and could allow emission of higher laser levels above Class 3R. 

 

Do not point lasers at people or animals. 

 

Never look into the laser aperture or laser beams. 

 

Do not point lasers in areas in which people can potentially get exposed, such as uncontrolled balconies, etc. 

 

Do not point lasers at highly reflective surfaces, such as windows, mirrors and shiny metal. Even laser 
reflections can be hazardous. 

 

Never point a laser at aircraft; this is a federal offense. 

 

Never point un-terminated laser beams into the sky. 

 

Do not expose the output optic (aperture) to cleaning chemicals. 

 

Do not use laser if the laser appears to be emitting only one or beams. 

 

Do not use the laser if the housing is damaged, open, or if the optics appear damaged in any way. 

 

Never open the laser housing. The high laser power levels inside of the protective housing can start fires, 
burn skin and will cause instant eye injury. 

 

Never leave this device running unattended. 

 

The operation of a class 3R laser show is only allowed if the show is controlled by a skilled and well-trained 
operator, familiar with the data included in this manual. 

 

The legal requirements for using laser entertainment products vary from country to country. The user is 
responsible for the legal requirements at the location/country of use. 

Always use appropriate lighting safety cables when hanging lights and effects overhead.

STOP AND READ ALL LASER SAFETY DATA

 

Содержание Cirrus

Страница 1: ...3351 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave External Power Supply Replaceable Fuse User Serviceable Duty Cycle Linkable Power ...

Страница 2: ...HAT IS INCLUDED 3 UNPACKING INSTRUCTIONS 3 MANUAL CONVENTIONS 3 ICONS 3 SAFETY INSTRUCTIONS 4 NON INTERLOCKED HOUSING WARNING 5 LASER SAFETY AND OPERATING INSTRUCTIONS 5 LASER EMISSION DATA 7 LASER EXPOSURE WARNING 7 2 INTRODUCTION 8 FEATURES 8 PRODUCT OVERVIEW 9 PROPER USAGE 10 3 SETUP 11 AC POWER 11 MOUNTING 12 Orientation 12 Rigging 12 4 OPERATION 13 Sound Active 13 Manual 13 AUTO 13 5 APPENDIX...

Страница 3: ...m the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons ...

Страница 4: ... connect the device to a dimmer pack Make sure the power cord is never crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Avoid direct eye exposure to the light source while it is on Lasers can be hazardous and have unique safety considerations Permanent eye injury and blindness is possible if lasers are used incorrectly Pay close attention to each safety REMARK a...

Страница 5: ...ven if it is aimed below people s faces such as on a dance floor Do not operate the laser without first reading and understanding all safety and technical data in this manual Always set up and install all laser effects so that all laser light is at least 3 meters 9 8 feet above the floor on which people can stand See Proper Usage section later in this manual After set up and prior to public use te...

Страница 6: ...Cirrus User Manual 6 2010 08 09 LASER SAFETY LABEL REPRODUCTION ...

Страница 7: ...SER EMISSION DATA LASER CLASSIFICATION CLASS 3R EQUIV TO US CLASS IIIA Green Laser Medium DPSS Nd YVO4 532 nm Red Laser Medium GaAIAs diode laser 650 nm typical Pulse Data All pulses 4 Hz 0 25 sec Divergence total light 160 degrees Laser Power of output from Aperture 5 mW As measured under IEC measurement conditions for classification LASER COMPLIANCE STATEMENT This laser product complies with EN ...

Страница 8: ...ht sky atmosphere with ever changing patterns 3 operating modes Sound activated Automatic Manual Separate control of laser effect and LED Laser separate red and green strobe rates or full on LED electronic dimmer 0 100 Laser LED rotation speed High power 5 W 1 000 mA LED Complies with FDA CDRH standards for Class 3R ...

Страница 9: ...g bracket Bracket adjustment knob 2 Rubber feet 4 Light output Red strobe speed Green strobe speed Microphone sensitivity adjustment pot Microphone Safety attachment point LED Dimmer Rotation speed Mode switch MANUAL MUSIC AUTO Power In Power ON OFF switch ...

Страница 10: ...ate for safe and effective mounting are easily sourced from your lighting vendor International laser safety regulations require that lasers must be operated in the fashion illustrated below with a minimum of 3 meters 9 8 ft of vertical separation between the floor and the lowest laser light vertically Additionally 3 meters of horizontal separation is required between laser light and audience or ot...

Страница 11: ...it is within the range of accepted voltages Always connect the fixture to a switched circuit Never connect the fixture to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used only as a 0 to 100 switch To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications c...

Страница 12: ...suitable C or O type clamp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration access and routine maintenance Safety cables must always be used Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or re...

Страница 13: ...e see the instructions below for further explanation 1 Plug the fixture into power 2 Turn the power switch to the ON position 3 Turn the mode switch to the MANUAL position 4 Combine the 4 knob adjustments to achieve the desired effect The DIMMER adjustment knob controls solely the blue LED NOT either laser All of the adjustment knobs will function in this mode Turn the RED GREEN STROBE adjustment ...

Страница 14: ... right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibil...

Страница 15: ...ables Install terminator Note Keep DMX cables separated from power cables or black lights 9 9 9 9 No laser output Bounce mirror motor may have shifted during shipping readjust 9 If you still have a problem after trying the above solutions please contact CHAUVET Technical Support Contact Us World Wide General Information CHAUVET 5200 NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 fax 954 929 556...

Страница 16: ... 0 2 A Power consumption 230 V 15 W 0 1 A max Inrush current 230 V 0 2 A LASERS Green laser 532 nm 30 mW Red laser 650 nm 80 mW Laser Type Diode DPSS Cooling Fan Cooled LED Deep blue 450 nm Quantity 1 x 5 W PHOTO OPTIC Coverage Angle 76 THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION Cirrus CIRRUS WARRANTY INFORMATION Fixture Warranty excluding laser diode 1 year limited warran...