background image

Achiever™

Supports

Adapta

®

Treatment Tables

A.E.R. Boot

®

Auto Edema Reduction Boot

AirMedex™

Alternating Pressure Mattress

boo-boo pac™

Child Size Bear-Shaped Cold Pack

Cambion

®

Shock Dampening Foot Care Products

Carpal-Trac™

Carpal Traction Accessory

ColPaC

®

Chilling Units and Reusable Cold Therapy Products

Conductor Gel™

Highly Conductive Ultrasound Gel

Contracture Products

Contracture Management Orthotic Products

CTS™

Carpal Tunnel Stretching Device

Dura-Stick™ Electrodes

Self-Adhesive Electrodes

EMG Retrainer

®

Dual Channel Surface EMG

ErgoWave

®

Intersegmental Traction Table

Flexi-Pac

®

I and II

Reusable Hot and Cold Compresses

Gel Medex™

Gel Mattress Overlay

Hydrocollator

®

Heating Units and HotPacs™

Hydrogel

®

Conductive Gelpad Dressings

Intelect

®

Legend

Ultrasound and Electrotherapy Products

Measurement Instruments

Dynamometers, Goniometers, etc.

Myossage

®

Massage Lotion

Nylatex

®

Elastic Wraps

Optiflex

®

Continuous Passive Motion

PALS™Electrodes

Neurostimulation Electrodes

Para-Care

®

Paraffin Wax Unit

Pillow Perfect™

Cervical Pillow Line

Pivotal Therapy System™

Orthotics for the Spine

ProPower Pillow™

Power Massage Pillow

PresSsion

®

Intermittent Compression

Pron Pillo

®

Positioning Pillow

Cervical Traction System

Clinical Cervical Traction

SPORT-PAC™

Soccer Ball Shaped Cold Pack

Therma-Wrap™

Hot and Cold Compression

Triton

®

Treatment and Traction Equipment

TX

®

Treatment and Traction Equipment

Vectra™ Series

Ultrasound and Electrotherapy products.

Wellness 1st™

Back Support

Women’s Contour Back Support

Back Support

More Trusted Products from Chattanooga Group, Inc.

ISO 9001 CERTIFIED

4717 Adams Road
P.O. Box 489
Hixson, TN 37343

U.S.A.

1-423-870-2281
1-800-592-7329

U.S.A.

1-800-361-6661

CANADA

+ 423-870-7200

INTERNATIONAL

+ 423-870-2046

INTL. FAX

www.chattgroup.com

© 2000 Chattanooga Group, Inc.

J2021B

The first real
innovation
in CPM in
a decade!

Содержание OptiFlex

Страница 1: ...User Manual The first real innovation in CPM in a decade ...

Страница 2: ...3 Installation 4 Operation Instructions 4 Quick Start 5 Pendant Functions 6 Other Pendant Functions 10 Pediatric Footplate Setup 11 User Maintenance 11 Technical Maintenance 11 Technical Specifications 12 Symbol Descriptions 13 Troubleshooting 14 Warranty 15 Parts Drawing 17 Parts List 18 OPTIFLEX ...

Страница 3: ... cold or heat DO NOT handle any electrical apparatus with wet hands DO NOT use OptiFlex as a toy Condensation could result and damage OptiFlex if unit is subjected to periods of low temperatures followed by periods of high temperatures DO NOT use on unstable surfaces or liquid filled devices such as water mattresses or flotation pads OptiFlex has been designed for maximum protection against the ex...

Страница 4: ...on However owing to Chattanooga Group s policy of continual improvement changes to these specifications may be made at any time without obligation on the part of Chattanooga Group Inc PRODUCT DESCRIPTION The OptiFlex is a continuous passive motion machine typically used postoperatively on total knee replacement and Anterior Cruciate Ligament ACL repair patients By repeatedly flexing and extending ...

Страница 5: ...ters Photo 1 2 Adjust OptiFlex femur component to match hip to knee measurement in centimeters Photo 2 3 Carefully place OptiFlex under the affected limb Align knee joint with the corresponding hinge point on unit Photo 3 4 Adjust the foot plate using the foot plate locking knobs so the patient s foot rests comfortably and the patient kit supports the leg from knee to foot Photo 4 5 Secure the lim...

Страница 6: ...d flexion angle for the time programmed EMERGENCY STOP START Starts or Stop treatment COMFORT ZONE Temporarily decreases the flexion ROM when discomfort is experienced DOWN ARROW Allows user to decrease treatment parameters UP ARROW Allows user to increase treatment parameters RESET Clear previous treatment settings and completed cycles PROGRESSIVE ROM Unit will automatically increase the programm...

Страница 7: ... button while pressing either the UP or DOWN ARROW Speed View and modify the speed parameter How to use To view the speed press and hold the SPEED button To modify the current speed press and hold the SPEED button while pressing either the UP or DOWN ARROW Extension Flexion Delay View and modify the delay time for the extension or flexion angles Using EXTENSION FLEXION DELAY will cause the carriag...

Страница 8: ...ET for 3 seconds the total unit time and cycles are temporarily displayed Emergency Stop Start Starts or stops the treatment How to Use Press the START STOP button to begin or end the treatment Comfort Zone Temporarily decreases the flexion ROM when discomfort is experienced during treatment How to Use Press and the carriage will immediately reverse direction to move toward the extension angle For...

Страница 9: ... Angle it will begin to slow down The deceleration rate will be half of the Programmed Speed when the carriage comes within 10 degrees of the flexion angle Upon reaching the flexion angle the carriage will reverse direction and resume the Programmed Speed as it moves towards the extension angle How to Use While pressing and holding the MODE button press the FAST BACK button to enable the FAST BACK...

Страница 10: ...vated the unit will automatically increase the Programmed Flexion Angle by one degree every hour up to a maximum of 5 per day How to Use While pressing and holding the MODE button press the PROGRESSIVE ROM button to enable the PROGRESSIVE ROM mode Set the desired Final Flexion Angle by pressing and holding the FLEXION Button while using the UP and DOWN Arrows Accept the Final Flexion Angle by pres...

Страница 11: ...t data for two 2 cycles then return to displaying Current Carriage Angle Patient Lock Out The Patient Lock Out feature prevents the patient from changing any parameter except COMFORT ZONE and START STOP To enable the Patient Lock Out feature Press and hold the UP ARROW and the MODE button for three seconds A single short beep will confirm that the feature has been activated Repeating the above seq...

Страница 12: ...mild household detergent may be used if desired Soft Goods may be laundered as required However the same Soft Goods should not be used from patient to patient Cleaning of Soft Goods will not meet the necessary sanitation guidelines Replace Soft Goods for each patient TECHNICAL MAINTENANCE No attempt should be made to disassemble the unit Maintenance and all repairs should be made by authorized per...

Страница 13: ... Suitable for continuous operation Unit Input 120 VAC 50 60 Hz 40 Watts Weight 28 Lbs 13 kg Length 37 in 94 cm Operation Knee Flexion ROM Limit 120 Knee Extension Limit 10 Hyper Extension Knee Speed Range 30 min to 150 min Nominal Maximum Patient Weight 350 Lbs 159kg Calf Length Range 10 to 23 5 in 25 4 to 59 7 cm knee joint to sole of foot Thigh Length Range 12 to 19 in 30 5 to 48 3 cm hip joint ...

Страница 14: ... should be transported and stored within the following conditions Temperature 0 140 F 32 60 C Humidity 0 75 Relative Humidity SYMBOL DEFINITION Standby Power ON Standby Power OFF Emergency Stop Start Type B Equipment Attention Consult Accompanying Documents ...

Страница 15: ...n only be used when ROM is greater than 30 degrees of Program med Extension Angle POSSIBLE CAUSE 1 Unplugged at wall outlet 2 ON OFF button not turned ON 3 Power loss 4 Pendant unplugged 5 Carriage travel blocked 6 Flexion angle set equal to extension angle 1 Motor overcurrent 2 Comfort Zone too small TROUBLESHOOTING The following is a solutions guide to minor performance problems Only qualified p...

Страница 16: ...e Product is returned to the Company or the dealer Company or the dealer will ship the replacement or the repaired Product to the consumer s facility All repairs must be performed by a service center authorized by Chattanooga Group Inc Any modifications or repairs performed by unauthorized centers or groups will void this warranty To participate in warranty coverage this Product s warranty registr...

Страница 17: ...o you TO OBTAIN SERVICE from Company or the selling dealer under this warranty the owner must do or abide by the following 1 A written claim must be made within the warranty period to the Company or the selling dealer If the claim is made to the Company written claim should be sent to 4717 Adams Road P O Box 489 Hixson TN 37343 USA Phone 423 870 7200 2 The Product must be returned to the Company o...

Страница 18: ...OPTIFLEX USER MANUAL 17 PARTS DRAWING ...

Страница 19: ...OPTIFLEX USER MANUAL 18 PARTS LIST ...

Страница 20: ...ynamometers Goniometers etc Myossage Massage Lotion Nylatex Elastic Wraps Optiflex Continuous Passive Motion PALS Electrodes Neurostimulation Electrodes Para Care Paraffin Wax Unit Pillow Perfect Cervical Pillow Line Pivotal Therapy System Orthotics for the Spine ProPower Pillow Power Massage Pillow PresSsion Intermittent Compression Pron Pillo Positioning Pillow Cervical Traction System Clinical ...

Отзывы: