Chassis Plans CPX-15, -17, -19 Technical Reference
Appendix A – Display Serial Control Programming
Page 38
Green Offset
for selected
colour
temperature
0xe9,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the Offset of the green
channel for the selected
colour temp. =
value/increment/decrement
Reset
Query
Green Offset for selected
colour temperature.
Blue Offset for
selected colour
temperature
0xea,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the Offset of the blue
channel for the selected
colour temp. =
value/increment/decrement
Reset
Query
Blue Offset for selected
colour temperature.
PIP Window
Auto Off
“0xee”, “0x41”
“0” |”1”
“?”
Auto Off / Auto On
Query
“0”- Off
“1”- On
Custom Sizing
0xef,
“0” | “1” | “2”
”?”
Custom sizing selection :
Overscan / Normal /
Custom
Query
“0” – Overscan
“1” – Custom
“2” – Normal
Table 18 - Advanced Controller Other Control
Function
Command
Description
Acknowledge (if enabled)
Select RS-232
acknowledge
0xc1, “0” | “1”
Disable/enable
command acknowledge.
“0” – acknowledge disabled.
“1” – acknowledge enabled.
Auto-setup
0xc3
Start auto-setup of
current vmode.
“0” – fail.
“1” – successful.
Command
availability
0xc4, n
Check whether a
command is available.
“0” – not available.
“1” – available.
Auto-calibration 0xc5
Start auto-calibration of
gain of the RGB
amplifier.
“0” – fail.
“1” – successful.
Freeze frame
0xc6, “0” | “1”
Unfreeze / freeze frame
“0” – unfreeze.
“1” – freeze.
Soft Power
On/Off
0xc8,
“0” | “1” |
“?”
Soft power
off/on
query
“0” – Turn off the LCD power
and
backlight. Turn off
memory
controller, Power down
DVI
Power down ADC,
Power
down Fclk PLL
“1” – Turn on the unit
Query video
input status
0xc9
Query the status of the
primary & pip status
“nn,nn” = input status
“nn,xx” digit = primary status: