Chassis Plans CPX-15, -17, -19 Technical Reference
Appendix A – Display Serial Control Programming
Page 27
Green level for
selected
colour
temperature
0xb5,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the level of the green
channel for the selected
colour temp. =
value/increment/decrement
Reset
Query
Green level for selected
colour temperature.
Range: “8””0”-“F””F”
Default: “F””F”
Blue level for
selected
colour
temperature
0xb6,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the level of the blue
channel for the selected
colour temp. =
value/increment/decrement
Reset
Query
Blue level for selected
colour temperature.
Range: “8””0”-“F””F”
Default: “F””F”
OSD turn off
0xbd
Turn off the OSD
“1” - successful
Backlight
brightness
control
0xe0,
nn | “+” | “-” |
“r” | “R” |
“?”
Set backlight brightness =
value/increment/decrement
Reset
Query
Backlight brightness.
Range: “0””0”-“F””F”
Default: “F””F”
e.g “1””0”
0xe0 0x31
0x30
* This control can only
function when JP2 sets
3-4 closed
* Apply for inverter
control voltage in range
of 0~5V.
Each step interval is in 1
Backlight
on/off control
0xe1,
“0” |
“1” |
“r” | “R” |
“?”
Set backlight brightness =
Disable backlight
Enable backlight
Reset
Query
Backlight working status
Backlight on/off.
“1” = normal (Default)
OSD menu
Lock
(Functon
available in
V1.80.00 or
later revision)
0xf6,
n | “0” | “1” |
“r” | “R” |
“?”
OSD menu Lock Off/ On
Reset
Query
“0” – OSD Lock Off
“1” – OSD Lock On
# - Function in ARGB mode only