background image

7

Product Manual - Nomad 830G MP

General

The new Nomad 830 MP Storage and Delivery System is 

another extension of the Perma-Cyl

® 

MicroBulk Storage 

System's innovative design and technology. The Nomad 

830 MP maintains all the features of the existing Perma-

Cyl system with the improved benefit of being mobile. The 

horizontal orientation and low profile of the Nomad 830 

MP as well as the design of the trailer base allows for easy, 

versatile handling and mobility.

This product was designed for the volume MicroBulk user 

in mind. Several features include fast fill capability (top 

and bottom) and extended hold time. The fast fill feature is 

accomplished with two filling valves, a top and a bottom 

fill valve which allows for the tank to be filled efficiently 

without any venting or loss of product (zero losses) under 

normal conditions 

The cylinder also uses the most advanced pressure 

building and vaporization technology today. The external 

PB vaporizer is mounted under the tank for optimum 

performance. The single flat fin design allows it to shed 

ice easily and maintain pressure during high gas use rate 

situations  

The external process vaporizer is a stand alone vaporizer 

mounted onto the trailer. For optimum performance, the 

trailer should be parked with this vaporizer in as much sun 

exposure as possible  

Installation Common Codes and 

Standards

The installer will need to find out what local city ordinances 

and which rules they are mandated to follow. One of the 

following standards may apply: 

•  Uniform Fire Code (UFC)

•  Compressed Gas Association (CGA)

•  National Fire Protection Association (NFPA)

Note:

  Regulations vary in every part of the 

country. Always consult local codes!

Initial Inspection

Upon receipt of a Nomad 830 MP, inspect for the following:

• 

Any shipping damage to the cylinder, trailer or vaporizer,  

including dents, scrapes, cuts, and broken or bent 

plumbing components. Report damage to the shipping 

company before accepting delivery  

• 

Check relief valves and burst discs for dirt or damage. 

• 

Warranty card, operator instructions sheet and user 

manual 

• 

Check to ensure that there is positive pressure on the 

inner vesser, normally about 20-25 psig. 

The Nomad 830 MP is shipped with NF purity nitrogen gas. 

Purging is necessary prior to filling.

Transport

The vessel is built to CGA-341 (49 CFR 173.320)

 

which 

requires the vessel pressure to be kept below 25.4 psig during 

transit. The relief valves on the Nomad 830 MP meet the 

ASME and CGA requirements  Maintaining transit pressure 

is accomplished through the road relief circuit/regulator.

Using the Trailer

The customer should attach all required tags, product 

labels, etc. before using the trailer. Both the pintle style and 

gooseneck trailers come with a Felling XPress trailer owner's 

manual. Always consult this publication before using the 

product. Most trailers are also equipped with a label that 

details the connection procedure (see Figure 1):

Figure 1 - Label detailing connection procedure

Introduction/Operation

Содержание Nomad 830G MP

Страница 1: ...PN 20945111 Rev C 2019 Chart Inc Designed and Built by Chart Inc 1300 Airport Dr Ball Ground GA 30107 USA 800 400 4683 Product Manual Nomad 830G MP MicroBulk On Site Storage and Delivery System...

Страница 2: ......

Страница 3: ...reparing the Tank for Use 8 Preparing the Tank for Transport 8 Primary Plumbing Circuits 8 Fill 8 Pressure Build 9 Economizer 10 Liquid Use 10 Gas Use 10 Safety Circuit 11 Vent Full Trycock 11 Other P...

Страница 4: ...vision Level Date Description A 01 11 2016 Original manual B 11 14 2018 Update cover photo and Specs Schematics C 12 28 2018 Further update on Schematics Plumbing and Filling options Troubleshooting 2...

Страница 5: ...use manifold Gooseneck Felling trailer 1 1 2 Bulk Fill Connection Kit Product Manual The Nomad Series Product Manual is designed to be used in conjunction with Nomad 830G MP If there are any questions...

Страница 6: ...nough to emphasize or repeat Acronyms Abbreviations The following acronyms abbreviations are used throughout this manual Ar Argon ASME American Society of Mechanical Engineers BARG Pressure Metric Gau...

Страница 7: ...henever removing parts or loosening fittings Failure to do so may result in personal injury due to the extreme cold and pressure in the cylinder Warning Use only replacement parts that are compatible...

Страница 8: ...for protection obviously the buddy is equally susceptible to asphyxiation if he or she enters the area to assist the unconscious partner unless equipped with a portable air supply Best protection is...

Страница 9: ...is even though an adequate oxygen supply sufficient for life is present Nitrogen and argon vapors in air dilute the concentration of oxygen necessary to support or sustain life Inhalation of high conc...

Страница 10: ......

Страница 11: ...out what local city ordinances and which rules they are mandated to follow One of the following standards may apply Uniform Fire Code UFC Compressed Gas Association CGA National Fire Protection Associ...

Страница 12: ...pressure is at or below 17 psig 6 Close the Vent isolation valve 7 Open the Road Relief isolation valve A 8 Connect the Trailer to the towing vehicle referencing the Felling trailer owner s manual 9 R...

Страница 13: ...psig As the tank pressure drops below the PB set point the regulator opens and allows liquid to flow off the bottom of the tank through the external PB vaporization coils and back into the gas phase o...

Страница 14: ...line regulator and the receiving equipment 3 Open the pressure building valve V 11 and V 15 4 Allow pressure to build to the operating pressure refer to gauge 5 Open the gas use valve V 10 6 Adjust th...

Страница 15: ...omad 830 MP there is a separate full trycock valve V 3 When the Nomad tank is filled by any delivery truck the full trycock must be used to fill the vessel When liquid starts to spit out of this valve...

Страница 16: ......

Страница 17: ...psig 5 Fill Nomad tank with 5000 standard cubic feet of product Primarily use the bottom fill on a FlexFill style tank Make sure some product is also routed through the top fill lines to purge them p...

Страница 18: ...The 6 port gas use manifold allows for high volumes of gas to be supplied to multiple users at once Photo 5 Regulating control Description Part Number Single Regulating Manifold 20939331 Dual Regulat...

Страница 19: ...nt manual for procedures to open the fill valve and vent valve of the receiving equipment 4 Open the liquid valve This valve can be adjusted to obtain the proper liquid flow rate 5 The pressure buildi...

Страница 20: ......

Страница 21: ...bing Diagrams PB Gas Use Inlet Item Part Description Qty 1 13462175 KIT CHECK VALVE 2 2 1712202 BALL VALVE 1 2 FPT 4 3 11529090 STRAINER 1 2 NPT 1 4 1810462 RELIEF VALVE 1 4 MPT 350 PSI 3 5 20869311 R...

Страница 22: ...UFFLER INERT MUFFLER OXYGEN 1 2 14871114 REGULATOR 1 4 NPT 17 PSI 1 3 1712202 BALL VALVE 1 2 FPT 4 4 11488574 RV BRS 1 2MPT 250 PSI 2 5 11671281 RPD ASSY INLINE 1 2MPT 375PSI 2 6 10907239 VALVE NEEDLE...

Страница 23: ...ty 1 20820974 TOP BTM FILL MANIFOLD 1 2NPT 1 2 1810462 RV BRS 1 4MPT 350PSI 1 3 11051090 VALVE CHECK BRS 1 2FPTX1 2FPT 1 4 1712202 VALVE BALL BRS 1 2 FPT 1 5 11671281 RPD ASSY INLINE 1 2 MPT 375 PSI 1...

Страница 24: ......

Страница 25: ...outlet pressures 3 Call appropriate equipment supplier or service technician Gas supply line hose or network contains excessive pressure drop 1 Check line for sufficient diameter 2 Remove all unneces...

Страница 26: ...ing at a pressure below the pressure stamped on the valve 3 Tap lightly on the side of the relief valve to attempt to dislodge any obstruction holding valve open Repeat several times if needed 4 If eq...

Страница 27: ...r regulator is malfunctioning 1 Reduce pressure setting by turning adjustment knob counter clockwise to the desired pressure setting and continuing normal gas use until pressure drops 2 Close PB isola...

Страница 28: ...ivery System is not functioning properly 1 Refer to Orca system Troubleshooting Transfer hose is obstructed e g hose is bent excessively crimped or plugged 1 Clean obstruction inspect hose for damage...

Страница 29: ...inches 243 centimeters Trailer Width 102 inches 259 centimeters Total Weight tare 9500 pounds 20 900 kilograms Total Weight gross 4 18 000 pounds 39 600 kilograms Vaporizer 4 700 SCFH NER day N2 1 18...

Страница 30: ...UILDING OUTLET D PRESSURE BUILDING INLET E LIQUID PHASE HIGH F VAPOR PHASE LOW G SAFETY CIRCUIT VENT H ECONOMIZER J FULL TRYCOCK NOMENCLATURE ID DESCRIPTION VM 1 TOP BTM FILL MANIFOLD W DRAIN V 1 FILL...

Отзывы: