background image

Item

Part No.

Description

Item

Part No.

Description

1

008/BU002

Rope Door Seal

38

008/FFW027

M10 Wavy Washer

2*

Door Seal Adhesive

39

010/BU061

Tabbed Locking Washer

3

006/BU018

Glass

40

008/FFN019

 M10 Half Nut

4

008/BU003

Glass Seal

41

008/BU049

Door Handle

5

004/KV23

Glass Retainer

42

008/BU110

Air Control Gasket

6

011/BU031

Brick Throat Plate

43

008/EZ006

Airbox Gasket

7

004/XV30

Brick Bracket

44

010/BU111

Air Control Top Slider Plate

8

011/BU029S

Set of Firebricks

45

004/BU112

Wood/Multifuel Surround Plate

9

002/BU015L

LH Side Fire Plate

46

010/BU130

Air Control Lower Plate

10

002/BU015R

RH Side Fireplate

47

004/BU115

Air Control Slider

11

002/BU016

Back Fireplate

48

004/BU113

Wood/Multifuel Selection Slide 

12

002/BU007

Front Fence

49

004/BR015

Clicker Retainer Plate

13

004/EZ095

Ashpan/Riddling Tool

50

008/ES36/01

Brass Ball Catch

14

004/BU017

Ashpan

51

004/ER016

Control Rod

15

010/BU097

Carrier Bar Clamping Bracket

52

012/BU037

Air Control Handle

16

002/BU030

Carrier Bar

53

008/BR052

Felt Washer

17

012/AY13

Idler Rod

54

004/BU120

Air Box Cover

18

010/BU077

Driver Bar Assembly

55

008/BR044

Duct Gasket

19

010/BU033

Mover Bar

56

004/BR054

Blanking Plate

20

002/CG20S8

Set of Grate Bars (8)

57

004/BR053

Air Inlet Spigot

21

002/BU098

Riddler Spigot

58

008/FFS067

Defra Stop

22

008/FFM081

Circlip

59

002/BU040

Door Hinge Bracket

23

002/BU009

Cast Top

60

008/FFW024

M8 Brass Washer

24

010/BU012

Blanking Plate

61

004/BU039

Door Hinge Shim

25

008/BU004

Flue Fixing Rope Seal

62

DY24

Spacer

26

008/BU021

Self Adhesive Webbing

63

012/BU011

Serial No. Label 

27

010/BU019

Blanking Plate Retainer

64#

001/BU010

Firebox

28

010/EY51

Clamping Plate

65#

004/BU081

Rear Heatshield

29

010/BU013

Top Flue Trim Ring

66#

004/BU080

Rear Panel

30#

002/BU001

Door Casting

67#

004/BU059

Rear Lower Panel

31

004/BU050

Rope Seal Channel

68#

004/BU093L

Left Side Panel

32

002/BU041

Upper Hinge

69#

004/BU093R

Right Side Panel

33

002/BU042

Lower Hinge

70#

010/BU058

Base Plate

34

010/BU063

Door Latch 

71#

002/BU072

Front Casting

35

010/BU064

Door Latch Bracket

72#

002/PV12B

Flue Collar

36#

010/BU060

Door Catch Arm

73

010/EW51

Ash Carrier (Optional Extra)

37

008/FFW029

M10 Brass Washer

74#

010/BU034

Vertical Rear Flue Adapter (Opt'l Extra)

* These items are not shown on the drawing
# Please specify colour when ordering.

To obtain spare parts please contact your local stockist 
giving Model, Part No. and Description. In case of 
difficulty contact the manufacturer at the address 
shown.
This drawing is for identification purposes only.

 

Issue A

 

 

®

CHARNWOOD SKYE 5 STORE STAND PARTS LIST 

17

72

74

66

68

24

23

26

27

28

25

67

60

59

61

63

64

70

42

43

44

45

46

57

55

58

54

53

47

48

50

49

51

52

71

14

6

7

8

8

69

22

21

15

20

11

9

10

19

17

18

16

34

35

32

33

1

31

3

4

30

36

41

12

65

55

56

5

62

29

13

40

39

36

38

37

37

Содержание Skye 5

Страница 1: ...Operating Installation Instructions ...

Страница 2: ......

Страница 3: ... need further help 9 INSTALLATION INSTRUCTIONS Health Safety Precautions CO Alarms Specification Chimney Hearth Fire Surround 11 Connection to Flues 12 Soot Doors 12 Pre Lighting Check 12 Commissioning 13 15 Multi Grate 5 Riddling 6 Controlling The Fire Unpacking The Stove 10 10 10 10 10 11 Optional Rear Heat Shield 13 Clean Air Act Information 13 Certification 14 Dimensions Skye 5 Skye 5 low Skye...

Страница 4: ...does not protrude beyond retainer d b Glass Wipewith damp lint freecloth removedwithaproprietarystoveglasscleaneror ceramichob cleaner Any stubborn deposits on the glass may be Throat plate Takedownonceamonth andclean Sweepsootydeposits intofire Chimney Havechimneyswept twiceayear Chimneycanbeswept throughstove Servicing Stoveshouldbeservicedbyaprofessionalat least onceayear MAINTENANCE AND CLEANI...

Страница 5: ... only be carried out once or twice a week Congratulations on becoming the owner of a Charnwood Skye Stove Your stove has been approved in smoke control areas to burn wood logs if it is used in accordance with these instructions It is very important that you read and understand these instructions before using the stove FUEL Before lighting the stove check with the installer that the work and checks...

Страница 6: ...nce the fire is up to temperature the airwash system will begin to work so allow the fire to become hot before adjusting the air control to the required setting During the lighting period do not leave the stove unattended Do not leave the door open except as directed above to avoid excessive smoke When relighting the stove leave the ash on the base if burning wood unless it is becoming too deep in...

Страница 7: ...rrying handle to prevent it falling off the tool Please avoid emptying hot ash into plastic liners or bins The Ashpan should be emptied regularly before it becomes too full Never allow the ash to accumulate in the ashpan so that it comes in contact with the underside of the grate as this will seriously damage the grate bars To make ash removal easier there are ash carriers available These may be p...

Страница 8: ...efore lighting It is important that the throat plate and all the stove flueways are kept clean in order to prevent potentially dangerous fume emission They should be cleaned at least monthly and more frequently if necessary It is necessary to let the fire out to carry out these operations To remove the throat plate first remove the fuel retainer item e page 5 and one side plate to allow enough roo...

Страница 9: ...ted this appliance will not emit fumes Occasional fumes from de ashing and re fuelling may occur Persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate actions should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire out and safely dispose of the fuel from the appliance ...

Страница 10: ...or use in a shared flue system 10 INSTALLATION INSTRUCTIONS In addition to these instructions the requirements of BS 8303 and BSEN 15287 1 2007 must be fulfilled Local Authority Bylaws and Building Regulations including those referring to national and European Standards regarding the installation of Solid Fuel burning appliances flues and chimneys must also be observed CO ALARMS Building regulatio...

Страница 11: ...s adequately fireproofed in accordance with local building regulations The hearth must be of fireproof material and at least 12mm 1 2in thick The positioning of the stove and the size of the hearth are governed by building regulations for Class 1 appliances These building regulations state that the hearth must extend in front of the stove by at least 225mm 9 in and to the sides of the stove by at ...

Страница 12: ...gs on the firebox as shown in Fig 11 Ensure that the clamping plate does not prevent the throat plate from seating correctly All flue connections must be well sealed It is possible to pass a 16 inch diameter sweeps brush through the appliance but in most back outlet installations it will be necessary to have a soot door to enable the chimney to be swept The optional vertical rear flue connector do...

Страница 13: ...ted smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by se...

Страница 14: ...UEL Space heating thermal output 5kW 5kW 5kW 5kW Emission of CO in combustion products 0 06 0 10 0 06 0 10 Mean flue gas temperature 239 C 247 C 239 C 247 C Energy efficiency 86 82 86 82 3 Particles mg m n 25 13 25 13 Minimum distance to combustible materials with Insulated flue Side Rear Minimum distance to combustible materials with Insulated flue rear heat shield Side Rear 300mm 270mm 300mm 90m...

Страница 15: ...15 423 301 498 122 81 808 509 160 390 833 623 509 390 648 160 63 249 709 63 64 524 Standard Model Low Model Optional vertical rear flue adaptor To suit 125mm 5 flue pipe DIMENSIONS mm CHARNWOOD SKYE 5 ...

Страница 16: ...op 22 008 FFM081 Circlip 59 002 BU040 Door Hinge Bracket 23 002 BU009 Cast Top 60 008 FFW024 M8 Brass Washer 24 010 BU012 Blanking Plate 61 004 BU039 Door Hinge Shim 25 008 BU004 Flue Fixing Rope Seal 62 DY24 Spacer 26 008 BU021 Self Adhesive Webbing 63 012 BU011 Serial No Label 27 010 BU019 Blanking Plate Retainer 64 001 BU010 Firebox 28 010 EY51 Clamping Plate 65 004 BU081 Rear Heatshield 29 010...

Страница 17: ...Inlet Spigot 22 002 BU098 Riddler Spigot 59 008 FFS067 Defra Stop 23 008 FFM081 Circlip 60 002 BU040 Door Hinge Bracket 24 002 BU009 Cast Top 61 008 FFW024 M8 Brass Washer 25 010 BU012 Blanking Plate 62 004 BU039 Door Hinge Shim 26 008 BU004 Flue Fixing Rope Seal 63 DY24 Spacer 27 008 BU021 Self Adhesive Webbing 64 012 BUL011 Serial No Label 28 010 BU019 Blanking Plate Retainer 65 001 BUL010 Fireb...

Страница 18: ......

Страница 19: ......

Страница 20: ... e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM y o u r p re m i e r d e a l e r ...

Отзывы: