background image

12

®

 INSTALLATION INSTRUCTIONS

load distributing plate.)

This may be stainless steel, cast iron, or thick wall steel pipe. Straight 
lengths of Charnwood Pipe to match the stove are available if 
required. 

There are several ways of connecting the stove to the flue. These are 
illustrated in Figs. 7 to 10.

CONNECTIONS TO FLUES

The stove must be connected to the flue using flue pipe of 

125mm 

(5") diameter - Skye 5.

If the top flue connection or optional vertical rear flue connector is 

Fig. 9. Horizontal register plate with top flue connection

used then the chimney may be swept through the appliance. 

Horizontal lengths of flue must be kept to a minimum and should not 
be more in length than the flue diameter.

The stove comes with the blanking plate (fig. 11) fitted to the top flue 
outlet. The seal for the 

top

 outlet is a 155mm dia ring of rope seal. 

The seal for the 

rear

 outlet is a length of adhesive backed fibre 

webbing supplied with instructions. This is applied to the flue collar or 
the Vertical Rear Flue adapter for rear outlet installations. For top 
outlet installations, the blanking plate must be removed, have the 
webbing fitted to its sealing face, and fitted to the rear flue outlet. 
Ensure that the fold on the clamping plate is in line with the lugs on 
the firebox as shown in Fig 11. Ensure that the clamping plate does 
not prevent the throat plate from seating correctly. All flue 
connections must be well sealed. 

It is possible to pass a 16 inch diameter sweeps brush through the 
appliance but in most back outlet installations it will be necessary to 
have a soot door to enable the chimney to be swept. The optional 
vertical rear flue connector does allow the chimney to be swept 
through the stove. 

The top outlet connection is made 

directly to the cast top, the Skye store stand and low models are 
supplied with a flue collar for rear outlet installations.

SOOT DOORS

PRE LIGHTING CHECK

Soot doors may either be in the actual brickwork 

of the chimney or in the register plate. Various positions of soot doors 
are shown in Figs. 7 to 10.

Ensure that the throat plate is fitted in the roof of the appliance. The 
location and positioning of the throat plate is shown in Fig. 6.

Check that the front fence is fitted correctly and that the door closes 
properly.

Fig. 10. Horizontal register plate with optional vertical rear flue connector

Alternative

Soot Door

Positions

Register Plate

With Soot Door

Alternative

Soot Door

Positions

Register Plate

With Soot Door

Fig. 11. Flue Blanking Plate.

Blanking Plate

Glass Fibre Webbing

Seal Blanking Plate with 

Glass Fibre Webbing

Blanking Plate

Back of Stove

Clamping Plate

M8 Nut

Clamping plate finishes 

flush with the inside face 

of the firebox top and 

bottom.

Содержание Skye 5

Страница 1: ...Operating Installation Instructions ...

Страница 2: ......

Страница 3: ... need further help 9 INSTALLATION INSTRUCTIONS Health Safety Precautions CO Alarms Specification Chimney Hearth Fire Surround 11 Connection to Flues 12 Soot Doors 12 Pre Lighting Check 12 Commissioning 13 15 Multi Grate 5 Riddling 6 Controlling The Fire Unpacking The Stove 10 10 10 10 10 11 Optional Rear Heat Shield 13 Clean Air Act Information 13 Certification 14 Dimensions Skye 5 Skye 5 low Skye...

Страница 4: ...does not protrude beyond retainer d b Glass Wipewith damp lint freecloth removedwithaproprietarystoveglasscleaneror ceramichob cleaner Any stubborn deposits on the glass may be Throat plate Takedownonceamonth andclean Sweepsootydeposits intofire Chimney Havechimneyswept twiceayear Chimneycanbeswept throughstove Servicing Stoveshouldbeservicedbyaprofessionalat least onceayear MAINTENANCE AND CLEANI...

Страница 5: ... only be carried out once or twice a week Congratulations on becoming the owner of a Charnwood Skye Stove Your stove has been approved in smoke control areas to burn wood logs if it is used in accordance with these instructions It is very important that you read and understand these instructions before using the stove FUEL Before lighting the stove check with the installer that the work and checks...

Страница 6: ...nce the fire is up to temperature the airwash system will begin to work so allow the fire to become hot before adjusting the air control to the required setting During the lighting period do not leave the stove unattended Do not leave the door open except as directed above to avoid excessive smoke When relighting the stove leave the ash on the base if burning wood unless it is becoming too deep in...

Страница 7: ...rrying handle to prevent it falling off the tool Please avoid emptying hot ash into plastic liners or bins The Ashpan should be emptied regularly before it becomes too full Never allow the ash to accumulate in the ashpan so that it comes in contact with the underside of the grate as this will seriously damage the grate bars To make ash removal easier there are ash carriers available These may be p...

Страница 8: ...efore lighting It is important that the throat plate and all the stove flueways are kept clean in order to prevent potentially dangerous fume emission They should be cleaned at least monthly and more frequently if necessary It is necessary to let the fire out to carry out these operations To remove the throat plate first remove the fuel retainer item e page 5 and one side plate to allow enough roo...

Страница 9: ...ted this appliance will not emit fumes Occasional fumes from de ashing and re fuelling may occur Persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate actions should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire out and safely dispose of the fuel from the appliance ...

Страница 10: ...or use in a shared flue system 10 INSTALLATION INSTRUCTIONS In addition to these instructions the requirements of BS 8303 and BSEN 15287 1 2007 must be fulfilled Local Authority Bylaws and Building Regulations including those referring to national and European Standards regarding the installation of Solid Fuel burning appliances flues and chimneys must also be observed CO ALARMS Building regulatio...

Страница 11: ...s adequately fireproofed in accordance with local building regulations The hearth must be of fireproof material and at least 12mm 1 2in thick The positioning of the stove and the size of the hearth are governed by building regulations for Class 1 appliances These building regulations state that the hearth must extend in front of the stove by at least 225mm 9 in and to the sides of the stove by at ...

Страница 12: ...gs on the firebox as shown in Fig 11 Ensure that the clamping plate does not prevent the throat plate from seating correctly All flue connections must be well sealed It is possible to pass a 16 inch diameter sweeps brush through the appliance but in most back outlet installations it will be necessary to have a soot door to enable the chimney to be swept The optional vertical rear flue connector do...

Страница 13: ...ted smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by se...

Страница 14: ...UEL Space heating thermal output 5kW 5kW 5kW 5kW Emission of CO in combustion products 0 06 0 10 0 06 0 10 Mean flue gas temperature 239 C 247 C 239 C 247 C Energy efficiency 86 82 86 82 3 Particles mg m n 25 13 25 13 Minimum distance to combustible materials with Insulated flue Side Rear Minimum distance to combustible materials with Insulated flue rear heat shield Side Rear 300mm 270mm 300mm 90m...

Страница 15: ...15 423 301 498 122 81 808 509 160 390 833 623 509 390 648 160 63 249 709 63 64 524 Standard Model Low Model Optional vertical rear flue adaptor To suit 125mm 5 flue pipe DIMENSIONS mm CHARNWOOD SKYE 5 ...

Страница 16: ...op 22 008 FFM081 Circlip 59 002 BU040 Door Hinge Bracket 23 002 BU009 Cast Top 60 008 FFW024 M8 Brass Washer 24 010 BU012 Blanking Plate 61 004 BU039 Door Hinge Shim 25 008 BU004 Flue Fixing Rope Seal 62 DY24 Spacer 26 008 BU021 Self Adhesive Webbing 63 012 BU011 Serial No Label 27 010 BU019 Blanking Plate Retainer 64 001 BU010 Firebox 28 010 EY51 Clamping Plate 65 004 BU081 Rear Heatshield 29 010...

Страница 17: ...Inlet Spigot 22 002 BU098 Riddler Spigot 59 008 FFS067 Defra Stop 23 008 FFM081 Circlip 60 002 BU040 Door Hinge Bracket 24 002 BU009 Cast Top 61 008 FFW024 M8 Brass Washer 25 010 BU012 Blanking Plate 62 004 BU039 Door Hinge Shim 26 008 BU004 Flue Fixing Rope Seal 63 DY24 Spacer 27 008 BU021 Self Adhesive Webbing 64 012 BUL011 Serial No Label 28 010 BU019 Blanking Plate Retainer 65 001 BUL010 Fireb...

Страница 18: ......

Страница 19: ......

Страница 20: ... e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM y o u r p re m i e r d e a l e r ...

Отзывы: