Important Information
It is most important that both you, the customer and the installation engineer not only follow the instructions in this
booklet, but that you are satisfied that the following conditions have been complied with.
This stove must not be used with any solid fuel, it is only suitable for natural gas or liquefied petroleum gas (LPG)
according to the burner unit supplied.
Ensure that the local gas distribution conditions, the nature of the gas pressure and the adjustment of the stove are
compatible.
Check that the burner data plate corresponds with the type of gas which is to be used i.e. natural gas or LPG.
The burner unit data plate is attached by a chain to the underside of the burner unit.
The site of the stove i.e. the chimney, the flue and hearth etc., must comply with current Building regulations and Codes of
Practice before the stove is installed.
The chimney flue outlet must be correctly positioned to align with the flue outlet on the stove that you have bought.
Connection to the chimney, the job of the installation engineer, is detailed in Section 1.
The stove must not be used with the door open.
Safety Reminders
Charnwood stoves are efficient appliances giving off convected, conducted and radiated heat. All the surfaces of the stove
(except the controls,) are working surfaces and become hot in use. They must not be touched or have any combustible
objects or material placed on or near them. Adequate precautions should always be taken to protect children, the elderly, the
infirm and pets, etc. from coming into contact with the stove.
Technical Data
Charnwood Grosvenor
Safety Information
Gas Flow
Rate
Input
Burner
(m
3
/h)
(kW)
Natural Gas (G20)
0.42
4.5
Natural Gas (G25)
0.488
4.5
LPG (G30)
0.103
3.7
Burner
Pilot Model
Injector
Injector Pressure
Nat. Gas (G20)
P4 48 Co Pilot NG20/A/400/M9/BE
BRAY 82/280
14 mbar
Nat. Gas (G25)
P4 48 Co Pilot NG20/A/400/M9/BE
BRAY 82/280
21.5 mbar
LPG (G30)
P4 49 Co Pilot LP37/A/400/M9/BE
BRAY 92/140
16 mbar
Page 2