Please go through this section with the installation
engineer so that you fully understand all the basic
operating and maintenance procedures for your stove.

The engineer will be happy to answer your questions and
give you any help you may need.

General Notes

This stove is not for use with any solid fuels. It is only
suitable for Natural (mains) Gas or LPG (Liquified
Petroleum Gas) when the correct burner is fitted.

Please remember that when the stove is alight it is very
hot.

EXCEPT FOR THE CONTROLS NEVER TOUCH

THE STOVE WITH YOUR BARE HANDS WHILST

IT IS HOT.

The stove must not be touched when it is in operation.
However, if you do need to do so after it has been turned
off and before it has completely cooled down (usually after
about one hour) please make sure that you wear stout oven
gloves.

Flue Spillage Safety Monitoring Device

A Safety Cut-Off System.

All stoves are fitted with an Oxygen Depletion Sensitive
Pilot so that should the flue and/or chimney become
blocked at any time, the stove will automatically cut off.

Normally the pilot can be re-ignited after waiting about
five minutes for the sensor to cool down, but in the event
of the system tripping, have the flue and chimney checked
by your installation engineer.

Lighting and controlling the stove.

Remember that the stove is designed to be operated with
the door and spinwheel securely closed.

1. Near the stove will be the gas isolation tap. Turn this to
the on position.

2. Between the front and rear legs on the right hand side of
the stove you will find the burner control knob, as shown
in Fig. 1.

a. Switching On/ Ignition.

Depress the control knob and turn counter clockwise. Gas
will flow to the pilot burner, the piezo igniter will give off
a high voltage spark & the pilot burner will light. (More
than one attempt may have to be made on first lighting the
fire.) Keep the control knob depressed for approximately
10 seconds to heat up the thermocouple, Turn the control
knob fully counter clockwise to release gas to the main
burner.

b. Control of Gas Flow.

Turning the control knob clockwise reduces the gas rate
from the maximum to the pre-set minimum setting.
Turning between maximum & minimum does not actuate
the piezo igniter. The control valve can only be set on pilot
by depressing the knob & turning it to the pre selected
pilot position.

c. Switching Off When in Pilot Position.

Press control knob and turn clockwise to off.

IMPORTANT

Interruption of Gas Supply.

Charnwood Grosvenor

Operating Instructions

Fig. 1. Gas Controls

Control Knob

Page 3

SV 2/00

Содержание Grosvenor

Страница 1: ...Operating and Installation Instructions CHARNWOOD GROSVENOR Bishops Way Newport Isle Of Wight PO3O 5WS U K Tel 01983 537799 Fax 01983 5377887 ...

Страница 2: ...flue outlet must be correctly positioned to align with the flue outlet on the stove that you have bought Connection to the chimney the job of the installation engineer is detailed in Section 1 The stove must not be used with the door open Safety Reminders Charnwood stoves are efficient appliances giving off convected conducted and radiated heat All the surfaces of the stove except the controls are...

Страница 3: ... tripping have the flue and chimney checked by your installation engineer Lighting and controlling the stove Remember that the stove is designed to be operated with the door and spinwheel securely closed 1 Near the stove will be the gas isolation tap Turn this to the on position 2 Between the front and rear legs on the right hand side of the stove you will find the burner control knob as shown in ...

Страница 4: ...h a suitable glass cleaner available from your stove supplier To The Customer PLEASE READ THE FOLLOWING PROCEDURES AND SERVICE CHECKS BUT PLEASE NOTE THEY MUST ALL BE CARRIED OUT BY A QUALIFIED INSTALLA TION ENGINEER IF THE DOOR GLASS BECOMES DAMAGED OR BROKEN DO NOT USE THE STOVE Glass Replacement 1 Before carrying out the glass replacement we suggest that for safety reasons the gas supply is tur...

Страница 5: ...m dust or dirt 4 Finally ensure that the thermocouple a very delicate electro mechanical device has not become damaged in any way If it is damaged a replacement pilot assembly should be obtained and fitted by your installation engineer FINAL REMINDERS We remind you that it is a legal requirement that the stove is installed by a qualified and accredited installation engineer Improper installation a...

Страница 6: ...e plate the gas valve will then be neatly located through cut out in right hand side of stove body Flue Spillage Monitoring System Charnwood Grosvenor stoves are fitted with an oxygen depletion sensitive pilot Location And Recommended Hearth And Fire Opening Specification The location of Charnwood Grosvenor model stoves should have the following space around them The hearth should protrude at leas...

Страница 7: ...tion The gas supply must be properly sized to provide the correct gas rate at running pressure when measured at the inlet valve The final connection to the stove must be made with a suitable 8mm dia gas pipe It is essential that a gas isolation tap is provided upstream of the stove in a position that is easily accessible Gas Pressure Make sure that there is adequate gas pressure and volume to the ...

Страница 8: ...ural Gas 1st Layer below shown dotted 11 12 13 14 15 16 17 18 19 20 21 L L L L L L L L L L L ø8 0 Holes Air Tunnel Air Tunnel 1 2 3 4 5 6 7 8 9 10 Fig 3 Coal Layer 1 Natural Gas Air Tunnel S S S S S L L L L L Page 8 SV 2 00 ...

Страница 9: ...s 2 3 LPG 16 17 18 19 20 21 22 23 24 25 26 1st Layer below shown dotted 3rd Layer L L L L L L L L S S S ø8 0 Holes 1 2 3 4 5 10 6 13 15 7 8 9 11 12 14 Fig 5 Coal Layer 1 LPG S S S S S L L L L L L L L L L Page 9 SV 2 00 ...

Отзывы: