11
Insertion in the outer container
The insertion in the Charly Light container (compressible) Art.# HFa187 now follows. By insertion in a different,
suitable container, or in a harness- integrated container, close attention absolutely must be paid to the valid
instruction manual.
Loop the deployment handle through the middle loop of the
inner container. Lead the bridle line out of the outer container
on the chosen side.
Thread two draw cords firstly through the loops and then
through the eyelets of the container flaps as indicated on the
numbered diagram.
Pull the loops through all the eyelets and fasten with the re-
lease pins from the deployment handle. Insert the end of the
release pins into the intended pockets. Remove the draw cords
!
Pull on the elastic cords (positioned on the sides) and position
using the cord stopper.
The container can be compressed using the two webbing
straps on the rear side !
No extra weak link threads are needed to secure the release
pins, as the Charly Loop-tensioner system is integrated in the
container described here !
1
2
3
4
2