24
LT6974 (ISS 4)
SECTION ELEVEN Maintenance (maintenance instructions)
GENERAL
Servicing should be carried out annually by a competent person such as a Gas safe-registered person in
accordance with the relevant regulations, to ensure the safe and correct operation of the appliance.
Before commencing any service or replacement of parts, turn off the gas supply to the fire. After servicing
check for gas soundness.
When ordering spare parts please quote appliance name and serial number, these can be found on the data
badge, which is located on the base of the appliance on the left hand side beneath the grill.
At least once a years check for debris in the catchment area behind the fire and in the flue way.
If soot has accumulated checks to establish cause rectify and clean flue or chimney accordingly.
PILOT LINTING
Check pilot aeration holes for linting, use a vacuum cleaner nozzle taking care not to damage the pilot head.
TO REMOVE THE BURNER TRAY
Remove RH and LH side covers undo glass fixing.
Remove glass panel.
Remove the loose fuel bed components.
Disconnect battery leads and remove appliance battery pack.
Remove gas supply cover.
Disconnect fire at inlet elbow and Undo the three burner tray fixing screws. Pull carefully forward and
remove.
For normal servicing the tray can be cleaned using a vacuum cleaner.
Whilst the tray is removed vacuum the firebox if necessary.
REPLACEMENT OF GAS CONTROL
Follow the burner tray removal sequence.
Disconnect the thermocouple from the rear of the gas valve.
Undo the three compression nuts securing the pipes to the gas valve and remove the two screws fixing the
valve to the bracket.
Clean, service or replace gas valve.
Re-assemble in the reverse order.
Turn on the gas supply, check for soundness and re-commission appliance.
REPLACEMENT OF INJECTOR
Follow the burner tray removal sequence.
Undo the compression nut on the supply pipe.
Unscrew the locking nut holding the injector on the chassis.
Clean or replace the injector.
NOTE: -Do not use a wire or a drill to clean out holes. Refer to the appliance data section for details.
Re-assemble in reverse order.
Содержание PARAGON P9
Страница 15: ...www charltonandjenrick co uk 15 LT6974 ISS 4 ...
Страница 26: ...26 LT6974 ISS 4 SECTION TWELVE Wiring Diagram maintenance instructions Attach to the valve ...
Страница 27: ...www charltonandjenrick co uk 27 LT6974 ISS 4 ...
Страница 28: ...28 LT6974 ISS 4 ...
Страница 29: ...www charltonandjenrick co uk 29 LT6974 ISS 4 ...