LT6974 (ISS 4)
SECTION EIGHT Siting the Appliance (installation instructions)
CLASS ONE
That is a conventional brick or stone chimney as used for a solid fuel appliance with an effective cross-sectional
dimension of 225 x 225 mm (9” x 9”) or a lined flue with a minimum diameter of 125mm (5”). The chimney must have
a minimum effective height of at least 3 metres. Any permanent flue restriction or variable dampers are to be
removed or locked fully open. The chimney should be swept prior to installation if it has previously been used with
solid fuel. This is not necessary if the flue has previously been used with a gas appliance or if it is a new installation.
Note: A brick or stone chimney with a 125 mm (5 ins) minimum diameter flue liner conforming to BS 715 may be
used. Provided a suitable sealing plate is fitted to the base of the liner and the appliance does not restrict the
opening into the liner. Ensure a smooth lead into the flue way and no combustible materials are used. A void of
50mm must be maintained from the top of the firebox to gather into flue.
PREPARING THE OPENING
The front face and the base of the fire opening must be flat to ensure that a good seal is formed between the rear
and base of the appliance and the chimney to avoid any reduction of natural draught.
The front face and the base of the fire opening must be flat to ensure that a good seal is formed between the rear
and base of the appliance and the chimney to avoid any reduction of natural draught.
Locate the slip mounting brackets (supplied as an optional extra) by hooking onto the existing studs on the fire
600-670mm
810-850mm
Floor
This area behind the trim/fascia must be clear of
combustible material and be flat for the seal.
330mm Min Depth
Содержание PARAGON P9
Страница 15: ...www charltonandjenrick co uk 15 LT6974 ISS 4 ...
Страница 26: ...26 LT6974 ISS 4 SECTION TWELVE Wiring Diagram maintenance instructions Attach to the valve ...
Страница 27: ...www charltonandjenrick co uk 27 LT6974 ISS 4 ...
Страница 28: ...28 LT6974 ISS 4 ...
Страница 29: ...www charltonandjenrick co uk 29 LT6974 ISS 4 ...