Charlton & Jenrick PARAGON P9 Скачать руководство пользователя страница 1

 

 

 

Owner’s Manual 

INCLUDES 

User, Maintenance, Service, and Installation 

Instructions

 

 

 

 

P9

 

 

Keep this booklet for service log and future reference

 

For use in Great Britain and Ireland. 

Literature NO 6974 (ISS 4) 

IMPORTANT 

 

 

 

This appliance is guaranteed for 12 months subject to conditions. The 5 year extended parts 

warranty will only be valid if the annual service recommended in this manual has been 

completed and appliance has been registered online. 

Содержание PARAGON P9

Страница 1: ...futurereference For use in Great Britain and Ireland Literature NO 6974 ISS 4 IMPORTANT This appliance is guaranteed for 12 months subject to conditions The 5 year extended parts warranty will only be valid if the annual service recommended in this manual has been completed and appliance has been registered online ...

Страница 2: ... Scheme on the opposite page and ensure your installer has filled in the appropriate checklist This in no way reduces your statutory rights Your warranty commences from the date of purchase and you must retain your receipt or invoice as proof of a purchase date THIS EXTENDED WARRANTY SPECIFICALLY EXCLUDES GLASS AND SOFT REFRACTORY COMPONENTS THE BULB AND ANY BATTERIES Terms and Conditions 1 The ap...

Страница 3: ...lations England and Wales All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme A Building Regulations Compliance Certificate will then be issued to the customer who should on receipt write the Notification Number on the Benchmark Checklist This product should be serviced regularly to optimise its safety efficiency and performance T...

Страница 4: ...r future reference we suggest you record the following details here and keep the receipt as proof of purchase This information may be asked for when you contact the helpdesk MODEL PARAGON P9 Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the base of the appliance behind the control cover Retailer Name Address Date Of Purchas...

Страница 5: ...r cleaning the coals or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped in polythene and be clearly labelled RCF waste These materials are not classified as hazardous waste and should be disposed of at a site licensed for the disposa...

Страница 6: ...ing Regulations or The Building Regulations Scotland or The Building Regulations Northern Ireland and The Current I E E Wiring Regulations if appropriate In IE Ireland the appliance must be installed by a competent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current Building Regulations and the current ETCI rules for electrical installation ...

Страница 7: ...iate button low setting or high setting There are 5 heat settings and the fire will give a double bleep when the maximum or minimum heat setting is reached To switch off the appliance press the OFF button or if the appliance is to be switch off for a short period it is recommended that the standby button be used This switches the main burner off but leaves the pilot on and will extend battery life...

Страница 8: ...PLIANCE BATTERIES 6 High Power Alkaline AA 1 5V Rechargeable batteries can be used providing they are a nickel metal hydride type 1 5V AA with a minimum capacity of 2200mAh A Remove the two side panels held on by magnets B Lift out the front grill C The battery holder is located in the centre of the Fireplace frame assembly Carefully lift out the battery holder and replace the six high power alkal...

Страница 9: ...orating or pet etc To gain access to the pilot please do the following Remove the two side covers LH and RH Undo the two M4 nuts retaining the glass fixing bracket using the tool provided then pull clear and from the location studs Carefully lift the glass panel from within the bottom location slot Remove the log fuel bed shapes and bark shapes Lift out the air tray assembly from the location poin...

Страница 10: ...F for at least four hours to ensure it is cool Remove the glass panel as described below Lay the glass panel down on a flat working surface on top of an old opened newspaper with the side to be cleaned uppermost Follow the instructions on the Hob Cleaner Bottle On stubborn stains where the appliance as been used for a long period without glass panel being cleaned use a new Brillo Pad well wetted w...

Страница 11: ...onents are delicate and they should be handled with great care The moulded shapes may be removed for cleaning They can be brushed very gently with a soft brush to remove dust or any deposits A vacuum cleaner may only be used after the loose components and moulded shapes have been removed CARE SHOULD BE TAKEN TO AVOID CONTACT WITH THE REFRACTORY LINING THIS IS A DELICATE SURFACE AND SHOULD NOT BE W...

Страница 12: ...oss the burner top plate Place two off the log shapes along the back edge of the air tray as shown Finally place a single layer of the large bark chippings along the front and sides of the air tray Place the one log shapes as shown Place the two log shapes as shown ...

Страница 13: ...www charltonandjenrick co uk 13 LT6974 ISS 4 Place the two log shapes as shown Place the final two log shapes as shown ...

Страница 14: ...cated on the back of the firebox This can be obtained by doing the following Remove the two side covers LH and RH which are held with magnets Undo the two M4 nuts retaining the glass fixing bracket using the tool provided then pull clear and remove from location studs Carefully lift the glass panel from within the bottom retaining slot Remove the log fuel bed shapes Lift out the air tray assembly ...

Страница 15: ...www charltonandjenrick co uk 15 LT6974 ISS 4 ...

Страница 16: ...eneath the grill Battery Remote handset 2 x AAA high power alkaline Appliance 6 x 1 5V AA high power alkaline Appliance Dimension NOTE The efficiency of this appliance has been measured as specified in BS7977 1 2009 A1 2013 and the result is 73 2 The gross calorific value of the fuel has been used for this efficiency calculation Gastec have certified the test data from which it has been calculated...

Страница 17: ...t Office IN IE Ireland The appliance must be installed by a competent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current building regulations and the current ETCI rules for electrical installation if appropriate Prior to the installation ensure that the local distribution conditions identification of type of gas and pressure and adjustment ...

Страница 18: ...ed Provided a suitable sealing plate is fitted to the base of the liner and the appliance does not restrict the opening into the liner Ensure a smooth lead into the flue way and no combustible materials are used A void of 50mm must be maintained from the top of the firebox to gather into flue PREPARING THE OPENING The front face and the base of the fire opening must be flat to ensure that a good s...

Страница 19: ...d CHECKING THE FLUE AND FIRE OPENING Check that the chimney conforms to the required specifications as previously stated Examine the condition and carry out any remedial work including removing any debris from the base If the flue has been used for solid fuel it should be swept prior to the installation Prior to installing the appliance a smoke test using a smoke bomb should be carried out to chec...

Страница 20: ...rebox using wall plugs and screw using the four holes within the firebox flange Refit the grommet over the pipe and seal around the inlet hole Remove the gas connection cover located within the burner shelf left hand side and connect to the restrictor elbow provided Refit the cover plate Note The isolation valve must be fitted at an angle to allow access to the restrictor plug plus gas pressure te...

Страница 21: ...et Operate the handset as described in section one Lay the fuel bed as described in section four Place the Glass panel within the location bracket within the fire box shelf assembly Retain the glass panel by using the glass fixing bracket and fixing nut provided Finally locate the Fireplace Covers LH and RH within the frame ...

Страница 22: ...e and check the pressure test point for soundness with detection fluid Refit the gas connection cover Fit the air tray within the location with the burner shelf LAY FUEL BED Important Refer to the Health Safety Notice located on page 5 of this booklet before laying or replacing any refractory material In the event of replacing fuel bed components please use only the specified number of components ...

Страница 23: ...here the fire is installed ADVISE CUSTOMER THAT The glass front of this fire acts as a dress guard conforming to BS 1945 1997 and satisfies the heating appliance regulations 1991 however a fireguard conforming to BS6539 1997 must be used to protect young children the elderly or infirm The curing effect of heating the logs and other refractory components will cause an initial odour This is due to t...

Страница 24: ...Y Remove RH and LH side covers undo glass fixing Remove glass panel Remove the loose fuel bed components Disconnect battery leads and remove appliance battery pack Remove gas supply cover Disconnect fire at inlet elbow and Undo the three burner tray fixing screws Pull carefully forward and remove For normal servicing the tray can be cleaned using a vacuum cleaner Whilst the tray is removed vacuum ...

Страница 25: ...upply pipe at the pilot Carefully pull off the ignition lead Disconnect the thermocouple at the end of the main control valve Remove the cross headed nut holding the pilot to the chassis Carefully remove the pilot shield oxy pilot Re assemble in reverse order REPLACEMENT OF CONTROL UNIT EDB Follow the burner tray removal sequence Disconnect leads from control unit and remove 2 bolts Re assemble in...

Страница 26: ...26 LT6974 ISS 4 SECTION TWELVE Wiring Diagram maintenance instructions Attach to the valve ...

Страница 27: ...www charltonandjenrick co uk 27 LT6974 ISS 4 ...

Страница 28: ...28 LT6974 ISS 4 ...

Страница 29: ...www charltonandjenrick co uk 29 LT6974 ISS 4 ...

Страница 30: ...facturer s instructions Hearth Requirements where fitted Is the hearth constructed from non combustible material Is the hearth a minimum of 12mm thick with a minimum floor to top surface of 50mm BS5871 or as per manufacturer s instructions Is the hearth for open fronted fires a minimum of 760mm wide and has 300mm projecting from the fire opening BS6871 or to manufacturer s instructions Mounting he...

Страница 31: ...ays use the manufacturer s specified spare part when replacing controls SERVICE 01 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 02 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 03 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 04 Date Engineer name Company na...

Страница 32: ...ommet 1092 Glass Panel Air Tray 6888 Silicone Sealing Strip 4818 AA Battery 12 Remote Control Hand Set Additional Fixings A 0411 Battery Holder 7mm Nut Spinner AAA x 2 Battery Owners Book Data Badge Warning Label 1409 ID Label Packing Labels Restrictor Plate Remote Reference Card 6713 Side covers RH LH inlet cover Aluminium Clip Serial Number Inspector ...