PPE-5011.E
Page 3 of 5
© 2013 Charleswater
Unit 17. Millbrook Business Park, Sybron Way • Crowborough, East Sussex TN6 3JZ United Kingdom
Phone: 00 44 (0) 1892-665313 • Internet:
6. Lighting of the green “PASS” LED indicates that the foot
ground assemblies are functioning properly.
7. If either red “Fail LO” or red “Fail HI” LEDs light and the
audible indicator sounds, the wearer should check the foot
grounding device immediately.
8. Repeat steps C through F with other foot.
Figure 7. Testing foot grounding devices with
Free Standing Test Fixture Assembly
and Operation (Model
)
Figure 8. The Free Standing Test Fixture
The
’s rugged steel pedestal tube is powder coated
in a non-conductive white finish that helps to prevent false
readings if contacted by skin or loose smocks.
Figure 9. Attaching pedestal to baseplate
Assembly
1. Remove 3 screws from baseplate.
2. Position pedestal on the baseplate with the tester
mounting bracket pointing away from the operator. Attach
pedestal to baseplate using the three screws provided.
Tighten with hex wrench provided.
3. Open the battery compartment and attach the snap
connector to the included 9 volt battery. Attach poster to the
wall at eye level in front of the tester location.
4. Install the tester on the bracket by aligning keyholes on
the back of tester with mounting studs on bracket. While
pushing up on thumb screw, insert the mounting studs into
the keyholes and slide the tester down. See figure 10.
THUMB
SCREW
Figure 10. Installing tester on bracket
5. Install the 10cm banana plug connector to “FOOTPLATE”
jack on the side of the unit. Insert ring terminal behind
thumb screw.
6. Twist the thumb screw clockwise to secure the tester to
the bracket.
Figure 11. Secure tester to bracket
WRIST STRAP TESTING
This test verifies that a continuous path between the
operator, wrist strap, and ground cord exists.
1. While wearing the wrist strap, plug the banana plug end
of the cord into the jack on the face of the unit marked
“WRIST CORD”.
2. Press rocker switch toward “WRIST CORD”.
3. Press the test button so that the unit activates. Hold down
for 2-3 seconds.