background image

PPE-5011.E

 Page 3 of 5

© 2013 Charleswater

Unit 17. Millbrook Business Park, Sybron Way • Crowborough, East Sussex TN6 3JZ United Kingdom

Phone: 00 44 (0) 1892-665313 • Internet: 

Charleswater.co.uk

6. Lighting of the green “PASS” LED indicates that the foot 

ground assemblies are functioning properly.
7. If either red “Fail LO” or red “Fail HI” LEDs light and the 

audible indicator sounds, the wearer should check the foot 

grounding device immediately.
8. Repeat steps C through F with other foot.

Figure 7. Testing foot grounding devices with 

99013

Free Standing Test Fixture Assembly 

and Operation (Model 

99004

)

Figure 8. The Free Standing Test Fixture

The 

99004

’s rugged steel pedestal tube is powder coated 

in a non-conductive white finish that helps to prevent false 

readings if contacted by skin or loose smocks.

Figure 9. Attaching pedestal to baseplate

Assembly

1. Remove 3 screws from baseplate.
2. Position pedestal on the baseplate with the tester 

mounting bracket pointing away from the operator. Attach 

pedestal to baseplate using the three screws provided. 

Tighten with hex wrench provided.
3. Open the battery compartment and attach the snap 

connector to the included 9 volt battery. Attach poster to the 

wall at eye level in front of the tester location.
4. Install the tester on the bracket by aligning keyholes on 

the back of tester with mounting studs on bracket. While 

pushing up on thumb screw, insert the mounting studs into 

the keyholes and slide the tester down. See figure 10.

THUMB 

SCREW

Figure 10. Installing tester on bracket

5. Install the 10cm banana plug connector to “FOOTPLATE” 

jack on the side of the unit. Insert ring terminal behind 

thumb screw.
6. Twist the thumb screw clockwise to secure the tester to 

the bracket.

Figure 11. Secure tester to bracket

WRIST STRAP TESTING

This test verifies that a continuous path between the 

operator, wrist strap, and ground cord exists.
1. While wearing the wrist strap, plug the banana plug end 

of the cord into the jack on the face of the unit marked 

“WRIST CORD”.
2. Press rocker switch toward “WRIST CORD”.
3. Press the test button so that the unit activates. Hold down 

for 2-3 seconds.

Содержание 99000

Страница 1: ...o uk Model Description 99000 Tester Banana Jack 99004 Tester with stand 99013 Footplate stainless steel 99065 AC Adapter 220V CAUTION Use only the AC adapter designed for this unit Using any other adapters may damage the unit and void the warranty Inspection Remove the tester from the carton and inspect for damage Items included with model 99000 1 Combo Tester 1 9 volt battery 1 80020 converter It...

Страница 2: ...round cord exists 1 While wearing the wrist strap plug the banana plug end of the cord into the jack on the face of the unit 2 Press rocker switch toward WRIST CORD 3 Press the test button so that the unit activates Hold down for 2 3 seconds Note DO NOT TOUCH ANY OTHER METAL WHILE PERFORMING TEST Figure 5 Testing of wrist strap grounding assemblies 4 Lighting of the green PASS LED indicates that t...

Страница 3: ...ing away from the operator Attach pedestal to baseplate using the three screws provided Tighten with hex wrench provided 3 Open the battery compartment and attach the snap connector to the included 9 volt battery Attach poster to the wall at eye level in front of the tester location 4 Install the tester on the bracket by aligning keyholes on the back of tester with mounting studs on bracket While ...

Страница 4: ...ghting of the green PASS LED indicates that the foot ground assemblies are functioning properly 5 If either red FAIL LO or FAIL HI LEDs light and the audible indicator sounds the wearer should check the foot grounding device immediately 6 Repeat steps A through C with other foot Calibration The models 99000 and 99004 are calibrated to factory standards We recommend that calibration is performed an...

Страница 5: ...t 227 grams Height 14cm L x 4cm H x 8cm W DRILL PATTERN FOR COMBO TESTER ACTUAL SIZE Limited Warranty Charleswater expressly warrants that for a period of one 1 year from the date of purchase Charleswater Combination Testers will be free of defects in material parts and workmanship labour Within the warranty period a unit will be tested repaired or replaced at Charleswater s option free of charge ...