background image

PPE-5011.E

 Page 4 of 5

© 2013 Charleswater

Unit 17. Millbrook Business Park, Sybron Way • Crowborough, East Sussex TN6 3JZ United Kingdom

Phone: 00 44 (0) 1892-665313 • Internet: 

Charleswater.co.uk

NOTE:

 DO NOT TOUCH ANY OTHER METAL WHILE 

PERFORMING TEST.

Figure 12. Testing of wrist strap grounding assemblies

4. Lighting of the green “PASS” LED indicates that the wrist 

strap and ground cord assemblies are functioning properly.
5. If either red “FAIL LO” or “FAIL HI” LEDs light and the 

audible indicator sounds, the wrist strap wearer should 

check the wrist strap assembly immediately.

TESTING FOOT GROUNDING DEVICES

When testing conductive shoes or heel straps, test each 

foot separately to ensure proper operation and complete 

protection.

1. Press rocker switch toward “FOOTPLATE”.
2. Place one foot on the baseplate. If the floor is conductive, 

lift the foot you are not testing off of the floor during this test. 

Make sure there is no ground cord plugged into the “WRIST 

CORD” jack.
3. Press the test button so that the unit activates. Hold down 

for 2-3 seconds.

NOTE:

 DO NOT TOUCH ANY OTHER METAL WHILE 

PERFORMING TEST.

Figure 13. Testing foot grounding devices

4. Lighting of the green “PASS” LED indicates that the foot 

ground assemblies are functioning properly.
5. If either red “FAIL LO” or “FAIL HI” LEDs light and the 

audible indicator sounds, the wearer should check the foot 

grounding device immediately.
6. Repeat steps A through C with other foot.

Calibration

The models 

99000

 and 

99004 

are calibrated to factory 

standards. We recommend that calibration is performed 

annually to ensure that the Tester is operating within limits. 

Due to its dual circuit design both test circuits of the Combo 

Tester must be calibrated individually. 

Charleswater offers a calibration unit that is specifically 

designed to simplify the calibration procedure. This unit 

comes calibrated to factory standards. For additional 

information on the 

99090

, ask for Technical Bulletin 

PPE-5034.E

.

750 Kilohm - 35 Megohm TEST RANGE - WRIST 

STRAPS

The following resistance should give the display shown:

Resistance Value

   

Test Output

(±5% or better)

675 Kilohm 

 

Red (Fail Lo)

825 Kilohm 

 

Green (Pass)

35 Megohm 

 

Green (Pass)

40 Megohm 

 

Red (Fail Hi)

Figure 14. Calibration of the Combo Tester 750K to 35 M 

range with the model 

99090

750 Kilohm - 35 Megohm TEST RANGE - FOOTWEAR

The following resistance should give the display shown:

Resistance Value

     

Test Output

 (±5% or better)

675 Kilohm 

Red (Fail Lo)

825 Kilohm 

  Green (Pass)

 35 Megohm 

  Green (Pass)

 40 Megohm 

  Red (Fail Hi)

Содержание 99000

Страница 1: ...o uk Model Description 99000 Tester Banana Jack 99004 Tester with stand 99013 Footplate stainless steel 99065 AC Adapter 220V CAUTION Use only the AC adapter designed for this unit Using any other adapters may damage the unit and void the warranty Inspection Remove the tester from the carton and inspect for damage Items included with model 99000 1 Combo Tester 1 9 volt battery 1 80020 converter It...

Страница 2: ...round cord exists 1 While wearing the wrist strap plug the banana plug end of the cord into the jack on the face of the unit 2 Press rocker switch toward WRIST CORD 3 Press the test button so that the unit activates Hold down for 2 3 seconds Note DO NOT TOUCH ANY OTHER METAL WHILE PERFORMING TEST Figure 5 Testing of wrist strap grounding assemblies 4 Lighting of the green PASS LED indicates that t...

Страница 3: ...ing away from the operator Attach pedestal to baseplate using the three screws provided Tighten with hex wrench provided 3 Open the battery compartment and attach the snap connector to the included 9 volt battery Attach poster to the wall at eye level in front of the tester location 4 Install the tester on the bracket by aligning keyholes on the back of tester with mounting studs on bracket While ...

Страница 4: ...ghting of the green PASS LED indicates that the foot ground assemblies are functioning properly 5 If either red FAIL LO or FAIL HI LEDs light and the audible indicator sounds the wearer should check the foot grounding device immediately 6 Repeat steps A through C with other foot Calibration The models 99000 and 99004 are calibrated to factory standards We recommend that calibration is performed an...

Страница 5: ...t 227 grams Height 14cm L x 4cm H x 8cm W DRILL PATTERN FOR COMBO TESTER ACTUAL SIZE Limited Warranty Charleswater expressly warrants that for a period of one 1 year from the date of purchase Charleswater Combination Testers will be free of defects in material parts and workmanship labour Within the warranty period a unit will be tested repaired or replaced at Charleswater s option free of charge ...

Отзывы: