background image

7

English

3  Product overview

3.1  Parts

   

WARNING! 

Note the marking on the power supply.

A

B

G

C

F

D

H

I

L3

L2

L1

E

Содержание Amp Guard

Страница 1: ...chargeamps com Charge Amps Amp Guard Installation Manual English...

Страница 2: ...harge Amps Amp Guard 13 5 2 Connect the current sensors 14 5 3 Connect voltage measurement 15 5 4 Mount and connect the power supply 16 5 5 Connect the Wi Fi antenna 17 5 6 Connect the LAN cable 17 5...

Страница 3: ...of using such information The manufacturer reserves the right to make changes to information published in this document without notice Visit www chargeamps com for the latest document releases Charge...

Страница 4: ...y Inspect the product for visible damage before use Never attempt to repair or use the product if it is damaged Do not immerse the product in water subject it to physical abuse or insert foreign objec...

Страница 5: ...d 230 VAC 15 50 Hz power supply Installation DIN rail mounting in a cabinet 1M Charge Amps Amp Guard 1M power supply Dimensions W x D x H Charge Amps Amp Guard 17 5 x 73 x 100 mm Power supply 17 5 x 5...

Страница 6: ...symbols Function performance class Measuring range Other complementary characteristics I 2 0 63 A V 2 85 256 VAC Climatic conditions Operating temperature 35 C to 55 C Relative humidity 0 90 Altitude...

Страница 7: ...7 English 3 Product overview 3 1 Parts WARNING Note the marking on the power supply A B G C F D H I L 3 L 2 L 1 E...

Страница 8: ...ors B Charge Amps Amp Guard C Wi Fi antenna D LAN port E Serial number and PIN F Terminal block for voltage measurement G 12 V power cable H 12 VDC power supply I Power supply AC input J Status indica...

Страница 9: ...supply which powers the Charge Amps Amp Guard Monitoring module consisting of a sensor cartridge and three connected current sensors including cables Terminal block for voltage measurement Wi Fi anten...

Страница 10: ...onnection Voltage measurement status Green light Ok Red light Error incorrect phase order No light Voltage measurement not connected Current measurement status Green light Ok Red light Error incorrect...

Страница 11: ...d will not be affected 1 Gently press the reset button at the top of the Charge Amps logo 2 All lights will turn off briefly once the reset has been initiated 4 Before installation 4 1 Recommended too...

Страница 12: ...on via a network cable LAN or Wi Fi 802 11b g n 2 4 GHz LAN connection if available is preferred for a more secure connection to the internet The network cable must be at least Cat6 Normally no firewa...

Страница 13: ...tor all power usage For single phase installations L2 and L3 shall not be used 5 1 Mount Charge Amps Amp Guard 1 Pull the DIN rail lock downwards and twist the Charge Amps Amp Guard onto the DIN rail...

Страница 14: ...phase The mounting direction is marked on the current sensor The arrow must point in the current direction IMPORTANT The current sensors must be connected to the correct phase and properly positioned...

Страница 15: ...as it may be needed if voltage measurement is connected in the future IT grid networks IT grid is used in parts of Norway Belgium and Albania In IT grid installations L2 must be connected to both L2 a...

Страница 16: ...ng the adjustment screw on the front of the power supply 1 Connect the power supply to the mains L N according to the labels on the power supply i e N to AC N left side and L1 to AC L right side 2 Ins...

Страница 17: ...Fi antenna to the Charge Amps Amp Guard 2 NB Depending on the type of cabinet an external Wi Fi antenna may be needed The external antenna must be of non grounded type 5 6 Connect the LAN cable If ap...

Страница 18: ...18 English 5 7 Overview of the electrical installation WARNING Note the marking on the power supply Optional see chapter Connect voltage measurement...

Страница 19: ...sing a smartphone tablet or a computer To avoid conflicting Wi Fi set to airplane mode turn on Wi Fi then connect to the hotspot 2 The network name i e the SSID is AG_ The last 7 digits letter of the...

Страница 20: ...20 English 3 When connected to the Wi Fi hotspot open a web browser and type in 192 168 251 1 as the URL 4 Enter the Charge Amps Amp Guard PIN to sign in 5 Click Login...

Страница 21: ...nformation about main fuses and network type in order to work correctly and effectively The supply voltage and current mapping settings can be used to fix installation issues and will normally remain...

Страница 22: ...will connect to the customer facility Wi Fi network 4 Sign in to the Wi Fi hotspot again 5 Make sure the communication status symbol lights up green within about a minute 6 4 Verify Charge Amps Amp Gu...

Страница 23: ...when current is below 2A as phase angles cannot be properly detected 2 Select the Status tab 3 Check that the measurements on the Status tab look correct There is also a System tab where the Charge Am...

Страница 24: ...ion Charge Amps Amp Guard needs to be configured in the Charge Amps Cloud to set up the Charge Amps load balancing function Sign in to the Charge Amps Cloud Partner Portal and use the Installation Wiz...

Страница 25: ...ttps www chargeamps com product charge amps amp guard Full product information https my charge space https my charge space partner Charge Amps Cloud User Portal Partner Portal Product information If y...

Страница 26: ...0 Rev 01 Charge Amps AB All rights reserved chargeamps com Charge Amps AB publ Fr sundaleden 2B 8th floor SE 169 75 Solna Sweden Charge Amps UK Ltd 3 More London Riverside 4th Floor London SE1 2AQ Uni...