background image

+12 V

GND

LOCK

+12 V

GND

S

  IM-8302

1 2 VDC

P

  ower Supply

Rear Panel

Ÿ

SIM-8302 

Power Output

 connects 

with 12V DC Power Supply and 

Power Input 

(P)

 in SIM-1DS.  

Ÿ

SIM-8302 

Ground Output

 connects 

with Ground of Power Supply and 

Ground Input 

(G)

 in SIM-1DS input.

Ÿ

SIM-8302 

Lock Signal Output 

(Yellow)

 connected to Signal Input 

(S)

 in Module SIM-1DS.

How to Connect:

 

3

 

INSTALLATION

 

Back Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dip Switches

(setup activation time)

Programming Chart

(8-200 seconds)

Relay Contacts

NO/NC - 12V AC or DC

LED Indicator

Flashes momentarily when 

activation signal is received

110 Connectors

Connections are parallel

(there is no “In” or “Out”)

Digital Lock Input

Signal, Ground, & Power

SIM-1DS

(Rear View)

S G P

Power Input / 

Digital Lock Signal

RED

BLACK

YELLOW

Содержание DP-8000 Series

Страница 1: ...INSTALLATION MANUAL SI SIM SIK DP 8000 IP Intercom System ELITE ...

Страница 2: ... CVT Upgrade Tool 8 Getting to a Command Prompt in Windows Verify your computer s network settings 9 Compare your computer s IP address with your SIM s IP address II Accessing and Configuring the Setup Interface Launching the user interface 10 Enter log in credentials LAN Settings 11 Device Settings 12 Access Settings 13 SIP Settings 14 Forward Account Settings 15 External Module Settings 17 Advan...

Страница 3: ... IP Rating IP 66 Rated Power 6W Standby Power Consumption 6W Operating Temperature 5ºF 131ºF Relative Humidity 20 93 Screen 3 5 Dot Matrix Dimensions H 14 75 W 6 5 D 2 Model SIM 8302 AllenW rench SealRing Waterproof jacket1 Waterproof jacket2 Cover Waterproof jacket3 Installation screws Network port seal ring Model SIK 8000 series ...

Страница 4: ...2 6 5 Camera LEDs Speaker Display Digital Keypad 14 75 13 75 Microphone Card Reader 5 5 Flush Mount Box Dimensions 2 depth ...

Страница 5: ...02 Lock Signal Output Yellow connected to Signal Input S in Module SIM 1DS How to Connect 3 INSTALLATION Back Panel Dip Switches setup activation time Programming Chart 8 200 seconds Relay Contacts NO NC 12V AC or DC LED Indicator Flashes momentarily when activation signal is received 110 Connectors Connections are parallel there is no In or Out Digital Lock Input Signal Ground Power SIM 1DS Rear ...

Страница 6: ...nable to connect equipment with RS485 interface RS485 interface enables to output 12V 100mA power 12V is not needed to wire if it is unused RS485 Interface RS485 Equipment Exit Door Detector Exit Door Detector Door Detector Switch ...

Страница 7: ...BUT1 EX BUT2 GND 12V COM DC 12V GND Network switch Exit button Strike Lock Waterproof CAT5 Cable Plug Hole l 2 36 7 125 4 SIK 8000 series Custom name address securing screw Securing screws _ DC strike power supply ...

Страница 8: ...on Ethernet Compatible with IEEE 802 3af 48V PoE standard GND 12V 12V GND PoE Switch CAT 5e Lock DC Power Supply NO COM NC Power DC12V optional Connect with magnetic lock CAT 5e GND GND V V 485 485 485 485 12V GND CTRL LOCK GND GND 12V Magnetic lock LOCK LOCK Power DC12V ST C5IDS relay pcb Accessory pack and cable management Schematic 2 Wiring a normally closed strike lock with a separate power su...

Страница 9: ...g Management Center Dial 0000 then press to call the management center If the management center is busy or unavailable the outdoor panel will display Busy then auto return to standby mode Press the button to end communication at any time during the call Video intercom with indoor monitor management center ID card reader Supports a maximum of 10 000 cards Access password unlocking Supports standard...

Страница 10: ...ss 1 to indicate that all settings will be back to Factory Default Settings press to confirm Access Control Card Reader Section There are two ways to delete the card information 1 If you registered the card via Management Software you can delete the card information in the software as well 2 If you registered the card via SIM panel you can reset the SIM to Factory Default Settings to delete the ca...

Страница 11: ...Click on Search to find the IP address of your SIM MDU intercom By default the address is 192 168 1 200 1 2 Verify your computer s LAN settings via Command Prompt The easiest way to open Command Prompt on a Windows machine is to press Win R on your keyboard Hold the Windows key down and then press R In the Run window type cmd then hit OK This will open Command Prompt Device ID IP address MAC addre...

Страница 12: ... your network mask and default gateway so you can reference them later 1 4 Compare your computer s IP address with the IP address of the SIM MDU Intercom If the first three sets of numbers 192 168 1 x from your computer s IP address match the SIM MDU Intercom s first three sets of numbers 192 168 1 x you can proceed to Step 2 If they don t match you can refer to the changing network settings porti...

Страница 13: ...sword to access the user interface The default credentials are admin and 123456 Default IP addresses 192 168 1 200 192 168 1 240 192 168 1 203 192 168 1 230 SIM 8302 Multi tenant station SIK 8000 Intercom w keypad DP 8000 IP Intercom series ST 3078 7 touchscreen ST 3108 10 touchscreen 192 168 1 220 Note Do not proceed to Step 3 until you have verified your computer and SIM Intercom are on the same...

Страница 14: ...e of the subnetting Gateway The gateway is the IP address of your router think of it as your devices gateway to get out of the local area network LAN It tells your devices where to send information if it needs to go to another network or the internet DNS You need to match your DNS address to the DNS address you ll get when you type ipconfig all into the command prompt You may also use 8 8 8 8 or 8...

Страница 15: ...ode Select Personal Panel Ring back you can choose 4 different ring back tones for the outdoor panel Language Choose which language you want to use Volume The volume of the ring back tone on the outdoor panel You can choose 1 6 TZ Set your time zone Forward Select one by one to make the unit call the first monitor and then call the rest in sequence or all at once to have it call all monitors at th...

Страница 16: ... eight different unlock passwords default is 0000 Typically used for management and maintenance personnel Card Reader 1 Register admin card input 0 in the Admin Card frame and confirm Then hold the admin card up to the reader when you hear the beep the card has registered successfully 2 Register the unlock cards Swipe the admin card first then swipe the new unlock card within 10 seconds It will so...

Страница 17: ...unt from Linphone Password for your SIP account This is only for the door station ALL phones and screens must have their own Linphone account Think of this as an individual phone number Bit rate The number of bits per second the unit will use to transmit voice and data We recommend 512k These settings should match on all devices indoor monitor mobile phone app etc Timeout Amount of time in seconds...

Страница 18: ...nal SIP server For calling a SIP Device with the IP address 192 168 1 230 When you dial 100 on the SIM Intercom it will call the device with the IP address 109019 is the Device ID address from the CVT Upgrade Tool 192 168 1 230 is the LAN IP address of the intercom 3 Make a SIP call to another SIP device using an External SIP server For calling a SIP Device with a SIP account When you dial 1114 on...

Страница 19: ...5 sip Device ID 192 168 1 230 1116 sip 109102 192 168 1 230 The example below shows the forward settings when using a registered SIP account S e t u p s i p s e r v e r f r e e a c c o u n t h t t p s w w w l i n p h o n e o r g f r e e s i p s e r v i c e h t m l Every device mobile phone touchscreen computer etc must have their own sip account Do not share sip accounts otherwise inconsistent cal...

Страница 20: ...d a call to a maximum of 8 devices In the example when the user presses 100 on the keypad it will call both the device with IP addresses 192 168 1 230 and 192 168 1 250 When using a monitor ST 3078 or ST 3108 the forward account would be in the monitor setup not the intercom DP 8000 series doorstation menu Forward to multiple devices you will select one by one or all at once in the device settings...

Страница 21: ...r if you are using one 2 9 Advanced Settings Advertising Used for touchscreen models Quick Call Used for touchscreen quick call guard button Speed Dial Used for touchscreen models RTSP Feed Refer to page 20 Note Anytime you change your settings you must click Submit before leaving the page sip cvt linphone org ...

Страница 22: ...m Room number to be associated with the name entered Delete Name To erase the name select the room number and delete it 2 10 Default This is where you go to reset the unit to default settings backup your current settings or restore from a previous backup To restore the SIM unit to default settings please refer to page 8 Note Anytime you change your settings you must click Submit before leaving the...

Страница 23: ...21 2 Forward SIP calls 2 11 Logout Note Anytime you change your settings you must click Submit before leaving the page ...

Страница 24: ... display streaming video to the Network Video Recorder NVR or in a video player e g VLC Media Player it is necessary to address the outdoor panel using the following initialization string rtsp address 8554 ch01 where the address is the IP address of the current outdoor panel The panel will then request a username and password the default user name is admin and the default password is 12345 Receivi...

Страница 25: ...23 ST 3108 3078 Menu Interface Monitor the Intercom station and unlock the door strike A list of snapshots or video recordings of visitors at your front d ...

Страница 26: ...itors enter 1 to 4 digits of the house and click building then enter the 2 digits of the front door and press door then enter 1 to 4 digits of the apartment and press call Changing the default IP to match the IP subnet and scheme 1 First connect a computer and the IP intercom unit to a switch to create a closed network with only these units connected 2 Next left click on the Network Setting Next l...

Страница 27: ...25 3 Next left click on Change adapter settings 4 Next right click on Local Area Connection ...

Страница 28: ...26 5 Next left click on Properties 6 Next left click once to highlight TCP IPv4 ...

Страница 29: ...7 Next left click Properties 26 27 ...

Страница 30: ...al Area Connection Properties window 9 First open Internet Explorer and type in the default IP to access the door station Http 192 168 1 203 Next you will be prompted to input a user name and password The default are as follows User admin Pass 123456 First open Internet Explorer and type in the default IP to access the door station Http 192 168 1 199 Last press the ok button 28 ...

Страница 31: ...ent failures due to accident acts of God misuse abuse or alteration of the equipment This warranty is extended only to the original purchaser when purchased through an authorized reseller A purchase receipt invoice or other proof of original purchase date will be required before warranty repairs are provided Mail in service can be obtained during the warranty period by calling 714 424 6500 A Retur...

Страница 32: ...nterference received including interference that may cause undesired operation This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This device and its antenna must not be located or operating in conjunction with any other antenna or transmitter 234 Fischer Ave Costa Mesa CA 92626 United States 714 424 6500 techsupport channelvision com www channe...

Отзывы: