background image

Source

C

H A N N E L 

V

I S I O N

Pwr

Source

C

H A N N E L 

V

I S I O N

Pwr

2

3

Pwr/Source Button

 ... Keypad On/Off control and source selection

control when in multi-mode.

LED Indicators

 ... Can show volume level or source selection. 

Top LED Indicator

 ... Flashes when IR signals are received.

IR Window

... 

Receives signals from IR remote
controls.

Volume Controls

... 

Increase or decrease volume level.

Features:

!

Compatible with all Channel Vision CAT5 audio systems

!

Supports IR control: compatible with the A0501 remote control

!

LEDs show volume level or source selection

!

These four LEDs illuminate to indicate 
which source input is selected.

!

The Pwr button is used for source selection.

Compatibility

How it Works

Basic Operation

The

 AB-124

 is an amplified keypad for Channel Vision’s single-source 

and multi-source CAT5 audio systems.  It provides convenient volume 
control and source selection capabilities, while its elegant decorator 
styling blends seamlessly with other wall switch devices.    

The AB-124 adheres to the same protocols as Channel Vision’s other CAT5 
audio hubs to ensure maximum compatibility.  However, when using the AB-
124 in a multi-source system, we recommend using Channel Vision’s multi-
source CAT5 audio matrix (model P-1044).  Multi-source CAT5 audio products 
from other manufacturers may not (and typically will not) use the same control 
codes for advanced features such as source selection.  

The AB-124 can be used in two different modes: 1) single source mode, 2) 
multi-source mode.  Mode selection is controlled by a jumper setting prior to 
installation.  When using the AB-124 with a single-source CAT5 audio hub, it 
should be set for the single-source mode.  In this mode, the unit provides basic 
controls: volume up, volume down, and power on/off.  When using it with a 
multi-source CAT5 aduio matrix, it should be set for multi-source mode.  In this 
mode, any zone can independently select and listen to any source at any time.  
Source selection can be done either from the AB-124 amplified keypad or by 
using the A0501 remote control.   

Using the AB-124 Amplified keypad... 

The Pwr (power) button located at the lower left of the keypad is used for 
source selection and to turn the unit on or off. When in single-source mode, 
press and release the Pwr button to toggle the keypad on or off. When in 
multi-source mode, if the keypad is off, press and release Pwr to turn it on.  
Press Pwr again to see the current source selection and press repeatedly to 
scroll through the 4 sources. Press and hold the power button to turn the 
keypad off.  While the keypad is off, press and hold the power button again to 
turn off the zone output of the P-1044.

 As you change sources when in multi-mode, you’ll notice that the top 4 LEDs 
illuminate corresponding to the source you have selected.  When source one 
is selected, the first  LED is illuminated, when source two is selected, the 
second LED is illuminated, and so on.

After a source is selected the LED will stay lit for 5 
seconds, then it will return to showing the current 
volume level.
Volume adjustments can be made using the 
up/down buttons to the right hand side of the 
keypad.  The keypad can be controlled from the 
A0501 remote control (see the section titled: Using 
the A0501 remote control for more details).

{

Содержание AB-124

Страница 1: ...AB 124 Multi Source Amplified Keypad Source CHANNEL VISION Pwr 0 1...

Страница 2: ...l Vision CAT5 audio systems Supports IR control compatible with the A0501 remote control LEDs show volume level or source selection T w T The AB 124 is an amplified keypad for Channel Vision s single...

Страница 3: ...any time Source selection can be done either from the AB 124 amplified keypad or by using the A0501 remote control Using the AB 124 Amplified keypad The Pwr power button located at the lower left of...

Страница 4: ...when the zone is on and audio is present Status will go dormant when audio is not present Status Active This jumper determines what happens when the status becomes active Typically when status becomes...

Страница 5: ...im plate Leave the gasket as is for a flush fit Remove the gasket to have the AB 124 stand above the plate Connectors To simplify installation the AB 124 has both 110 and RJ 45 inputs Only one of the...

Страница 6: ...CAT5 Audio Distribut on M dule i o M del o 01 P 1 4 2 4VDC Power 1 2VDC Status y S stem Sys m te np I ut L c l o a I p n ut e 1 Zon e 2 Zon Zone 3 Zone 4 E pa s on x n i Output Local ri ty P ori Signa...

Страница 7: ...L TM VISION CHANNEL VISION TM Model P 1044 Active Active Active Active k Lin In k Lin Out o Z ne 1 Zone 2 Zone 3 Zone 4 Source 1 Source 2 Source 3 Source 4 Common IR Source 4 IR Source 3 IR Source 2 I...

Страница 8: ...of the AB 124 and press the desired button Zone Power Turns on off the zone output of the P 1044 Power Turns on off the AB 124 VOL Controls volume for the keypad LED indicators on the AB 124 will ligh...

Страница 9: ...or multi mode All of the AB 124 keypads connected to the P 1014 will be able to select any of the 4 input sources However if the source selection is changed in one sub zone it will also be changed for...

Страница 10: ...e sensor on the device you are trying to control 4 If no audio is heard check to make sure that the audio source is playing then press the power button on the AB 124 to make sure it is turned on a Not...

Страница 11: ...ultiple turns will cause you to cut into the inner wires 3 Inspect the inner wires for damage If any wires are cut start over at step 1 Check for damage Green White Green Orange White Blue Blue White...

Страница 12: ...re warranty repairsareprovided Mail in service can be obtained during the warranty period by calling 800 840 0288 toll free A Return Authorization number must be obtained in advance and can be marked...

Отзывы: